文献速递心脑血管急症重症综合管理与镇静镇痛

床旁聚焦经胸超声心动图在急性非创伤性胸主动脉综合征中的诊断准确性:系统评价与Meta分析

Bedside-focused transthoracic echocardiography in acute atraumatic thoracic aortic syndrome: a systematic review and meta-analysis of diagnostic accuracy.
PubMed 文献 · Eur J Emerg Med · 2024-08-28
一句话结论床旁聚焦经胸超声心动图对A型主动脉夹层特异性高(92%)、敏感性中高(89%),对B型敏感性低(65%),对壁内血肿和穿透性主动脉溃疡诊断准确性不明确。

本文对16项研究、共4569例疑似急性非创伤性胸主动脉综合征的急诊成年患者进行系统评价与Meta分析,评估床旁聚焦经胸超声心动图(TTE)的诊断准确性。A型主动脉夹层(直接观察内膜片)汇总敏感性89%(95%CI 82-94%)、特异性92%(95%CI 88-95%);B型夹层汇总敏感性65%(95%CI 45-80%)、特异性100%(95%CI 0.69-100%)。间接征象中,主动脉瓣反流汇总敏感性64%、特异性94%,胸主动脉瘤敏感性92%、特异性87%,心包积液敏感性39%、特异性94%。结论认为床旁聚焦TTE对A型和B型夹层特异性高,对A型敏感性中高、对B型差,对壁内血肿和穿透性主动脉溃疡诊断准确性不明确。

要点

  • A型主动脉夹层:床旁聚焦TTE直接观察内膜片,汇总敏感性89%(95%CI 82-94%)、特异性92%(95%CI 88-95%)。
  • B型主动脉夹层:床旁聚焦TTE汇总敏感性65%(95%CI 45-80%)、特异性100%(95%CI 0.69-100%)。
  • 间接征象:主动脉瓣反流敏感性64%、特异性94%;胸主动脉瘤敏感性92%、特异性87%;心包积液敏感性39%、特异性94%。
  • 对壁内血肿和穿透性主动脉溃疡的诊断准确性不明确。
  • 纳入16项研究、4569例患者,A型夹层患病率11%(范围1.4-45.7%),B型7%(范围1.8-30.55%)。

适用人群与场景

  • 急诊科就诊的疑似急性非创伤性胸主动脉综合征的成年患者。

研究设计与关键结果

  • 系统评价与Meta分析,纳入16项研究(跨越六十年),共4569例患者。
  • A型主动脉夹层患病率11%(范围1.4-45.7%),B型夹层患病率7%(范围1.8-30.55%)。
  • A型夹层(直接观察内膜片):汇总敏感性89%(95%CI 82-94%),特异性92%(95%CI 88-95%)。
  • B型夹层:汇总敏感性65%(95%CI 45-80%),特异性100%(95%CI 0.69-100%)。
  • 主动脉瓣反流:汇总敏感性64%(5.2-98.2%),特异性94%(92-96.1%)。
  • 胸主动脉瘤:汇总敏感性92%(54-99.2%),特异性87%(62-97%)。
  • 心包积液:汇总敏感性39%(33.8-45%),特异性94%(92-95%)。
  • 对壁内血肿和穿透性主动脉溃疡的诊断准确性不明确。

证据类型、等级与局限

  • 证据类型:系统评价与Meta分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 床旁聚焦TTE对A型和B型主动脉夹层特异性高,对A型敏感性中高、对B型差,对壁内血肿和穿透性主动脉溃疡诊断准确性不明确。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

The objective of this review was to assess the diagnostic accuracy of bedside-focused transthoracic echocardiography (TTE) in acute atraumatic thoracic aortic syndrome in adults. We performed a systematic review and meta-analysis of publications that described the use of bedside-focused TTE on adults presenting to emergency care settings with suspected atraumatic thoracic aortic syndrome. Studies were identified using keyword and MeSH on relevant databases as well as grey literature, followed by abstract screening and study selection by two independent reviewers. Sixteen studies over six decades were included in the meta-analysis ( n = 4569 patients). The prevalence of type A thoracic aortic dissection was 11% (range 1.4-45.7%) and type B dissection was 7% (range 1.8-30.55%). Pooled sensitivity and specificity for type A dissection (through direct TTE visualisation of an intimal flap) were 89% [95% confidence interval (CI), 82-94%] and 92% (95% CI, 88-95%), respectively. For type B dissection, pooled sensitivity was 65% (95% CI, 45-80%) and specificity was 100% (95% CI, 0.69-100%). Regarding indirect TTE signs, pooled sensitivities and specificities were 64% (5.2-98.2%) and 94% (92-96.1%), respectively for aortic valve regurgitation, 92% (54-99.2%) and 87% (62-97%) for thoracic aortic aneurysm and 39% (33.8-45%) and 94% (92-95%) for pericardial effusion. In this systematic review and meta-analysis, bedside-focused TTE has high specificity for type A and B dissection, a moderate to high sensitivity for type A but poor for type B, and unclear diagnostic accuracy for intramural haematoma and penetrating aortic ulcer.

来源:Eur J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Mani N, Cherian N, Burkert J, et al. Bedside-focused transthoracic echocardiography in acute atraumatic thoracic aortic syndrome: a systematic review and meta-analysis of diagnostic accuracy. Eur J Emerg Med. 2024. PMID: 39196539. doi:10.1097/MEJ.0000000000001174

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。