调度护士处理疑似院外心脏骤停时使用配备自动体外除颤器无人机的体验——一项定性研究

Dispatcher nurses' experiences of handling drones equipped with automated external defibrillators in suspected out-of-hospital cardiac arrest - a qualitative study.
PubMed 文献 · Scand J Trauma Resusc Emerg Med · 2024-08-21
一句话结论调度护士对无人机递送自动体外除颤器的电话辅助流程依从性不一,对中断心肺复苏按压取用自动体外除颤器的可接受时长存在不确定性,需改善技术支持和培训。

该定性研究采用现象学方法,对瑞典哥德堡一个紧急医疗调度中心的10名注册护士进行半结构化访谈,并用定性内容分析探讨其在疑似院外心脏骤停时调度配备自动体外除颤器无人机的体验。结果形成三个类别:护士对电话辅助调度自动体外除颤器无人机的流程依从性不一;对中断心肺复苏流程以取用无人机递送自动体外除颤器的可接受时长感到不确定;多数认为同事支持很重要。作者认为技术支持和培训需改善,以进一步优化调度护士处理无人机递送自动体外除颤器的行动。

要点

  • 10名瑞典哥德堡紧急医疗调度中心注册护士接受半结构化访谈,采用现象学方法与定性内容分析。
  • 护士对电话辅助调度配备自动体外除颤器无人机的流程依从性不一。
  • 护士对中断心肺复苏流程以取用无人机递送自动体外除颤器的可接受时长感到不确定。
  • 多数护士认为同事支持很重要;作者认为技术支持和培训需改善以优化行动。
  • 尽管存在院外心脏骤停无人机调度的电话辅助流程,其使用很少。

适用人群与场景

  • 瑞典哥德堡一个紧急医疗调度中心雇佣的10名注册护士,处理疑似院外心脏骤停时调度配备自动体外除颤器无人机的场景。

研究设计与关键结果

  • 定性半结构化访谈研究,采用现象学方法,纳入10名注册护士,数据用定性内容分析。
  • 形成三个类别:对电话辅助调度自动体外除颤器无人机流程的依从性不一;对中断心肺复苏流程取用无人机递送自动体外除颤器的可接受时长存在不确定性;多数认为同事支持重要。
  • 作者认为技术支持和培训需改善,以进一步优化调度护士处理无人机递送自动体外除颤器的行动。
  • 尽管存在院外心脏骤停无人机调度的电话辅助流程,其使用很少。

证据类型、等级与局限

  • 证据类型:定性研究(半结构化访谈,现象学方法)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,随着全球更广泛探索无人机在院外心脏骤停中递送自动体外除颤器,本研究可能对实施类似方法的其他国家有益。
  • 作者提出在调度中心实施此类方法时需考虑的具体方面:改善技术支持和培训,以进一步支持旁观者使用无人机递送的自动体外除颤器。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Reducing the time to treatment by means of cardiopulmonary resuscitation (CPR) and defibrillation is essential to increasing survival after cardiac arrest. A novel method of dispatching drones for delivery of automated external defibrillators (AEDs) to the site of a suspected out-of-hospital cardiac arrest (OHCA) has been shown to be feasible, with the potential to shorten response times compared with the emergency medical services. However, little is known of dispatchers' experiences of using this novel methodology.

METHODS: A qualitative semi-structured interview study with a phenomenological approach was used. Ten registered nurses employed at an emergency medical dispatch centre in Gothenburg, Sweden, were interviewed and the data was analysed by qualitative content analysis. The purpose was to explore dispatcher nurses' experiences of deliveries of AEDs by drones in cases of suspected OHCA.

RESULTS: Three categories were formed. Nurses expressed varying compliance to the telephone-assisted protocol for dispatch of AED-equipped drones. They experienced uncertainty as to how long would be an acceptable interruption from the CPR protocol in order to retrieve a drone-delivered AED. The majority experienced that collegial support was important. Technical support, routines and training need to be improved to further optimise action in cases of drone-delivered AEDs handled by dispatcher nurses.

CONCLUSIONS: Although telephone-assisted routines for drone dispatch in cases of OHCA were available, their use was rare. Registered nurses showed variable degrees of understanding of how to comply with these protocols. Collegial and technical support was considered important, alongside routines and training, which need to be improved to further support bystander use of drone-delivered AEDs. As the possibilities of using drones to deliver AEDs in cases of OHCA are explored more extensively globally, there is a good possibility that this study could be of benefit to other nations implementing similar methods. We present concrete aspects that are important to take into consideration when implementing this kind of methodology at dispatch centres.

来源:Scand J Trauma Resusc Emerg Med,查看原文。版权归原作者所有。