文献速递重症综合管理与镇静镇痛心脑血管急症

中心静脉压能否帮助识别机械通气危重症患者的急性右心室功能障碍

Can central venous pressure help identify acute right ventricular dysfunction in mechanically ventilated critically ill patients?
PubMed 文献 · Ann Intensive Care · 2024-07-20
一句话结论在机械通气危重症患者中,CVP<10 mm Hg几乎可排除伴全身静脉淤血的右心室功能障碍,但CVP不能用于识别一般性右心室功能障碍。

该回顾性研究纳入518例接受经胸超声心动图检查和CVP监测的机械通气危重症患者,按右心室功能及下腔静脉直径、肝静脉多普勒评估的全身静脉淤血情况分为右心室功能正常组(301例)、孤立性右心室功能障碍组(164例)和右心室功能障碍伴淤血组(53例)。CVP识别右心室功能障碍伴淤血的AUC为0.839(95%CI 0.795-0.883,P<0.001),最佳截断值10 mm Hg,敏感度79.2%、特异度69.4%、阴性预测值96.7%、阳性预测值22.8%,9-12 mm Hg灰色带涵盖95例(18.3%)。CVP识别所有右心室功能障碍的AUC为0.616(95%CI 0.567-0.665,P<0.001),灰色带5-12 mm Hg涵盖349例(67.4%)。作者认为CVP可能有助于识别机械通气危重症中伴全身静脉淤血的急性右心室功能障碍患者,但准确性有限。

要点

  • CVP识别右心室功能障碍伴全身淤血的AUC为0.839(95%CI 0.795-0.883,P<0.001),最佳截断值10 mm Hg。
  • CVP<10 mm Hg排除右心室功能障碍伴淤血的阴性预测值为96.7%,敏感度79.2%、特异度69.4%、阳性预测值22.8%。
  • CVP识别右心室功能障碍伴淤血在9-12 mm Hg存在灰色带,涵盖95例(18.3%)。
  • CVP识别所有右心室功能障碍的AUC仅0.616(95%CI 0.567-0.665,P<0.001),灰色带5-12 mm Hg涵盖349例(67.4%)。
  • 作者认为CVP不应被用于识别一般性右心室功能障碍。

适用人群与场景

  • 接受机械通气并同时进行经胸超声心动图检查和CVP监测的危重症患者。

诊断标准与关键阈值

  • 右心室功能正常:TAPSE ≥ 17 mm、FAC ≥ 35%且S' ≥9.5 cm/sec。
  • 孤立性右心室功能障碍:TAPSE < 17 mm或FAC < 35%或S' <9.5 cm/sec,且IVCD ≤ 20 mm或HV S ≥ D。
  • 右心室功能障碍伴淤血:TAPSE < 17 mm或FAC < 35%或S' <9.5 cm/sec,且IVCD > 20 mm和HV S < D。
  • CVP识别右心室功能障碍伴淤血的最佳截断值为10 mm Hg。

研究设计与关键结果

  • 回顾性研究纳入518例机械通气危重症患者,右心室功能正常组301例、孤立性右心室功能障碍组164例、右心室功能障碍伴淤血组53例。
  • CVP识别右心室功能障碍伴淤血的AUC为0.839(95%CI 0.795-0.883,P<0.001),最佳截断值10 mm Hg,敏感度79.2%、特异度69.4%、阴性预测值96.7%、阳性预测值22.8%。
  • CVP识别右心室功能障碍伴淤血在9-12 mm Hg存在灰色带,涵盖95例(18.3%)。
  • CVP识别所有右心室功能障碍的AUC为0.616(95%CI 0.567-0.665,P<0.001),灰色带5-12 mm Hg涵盖349例(67.4%)。

证据类型、等级与局限

  • 证据类型:回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为CVP可能有助于识别机械通气危重症中伴全身静脉淤血的急性右心室功能障碍患者,但准确性有限。
  • 作者认为CVP<10 mm Hg几乎可排除右心室功能障碍伴淤血。
  • 作者认为不应使用CVP识别一般性右心室功能障碍。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the relationship between central venous pressure (CVP) and acute right ventricular (RV) dysfunction in critically ill patients on mechanical ventilation.

METHODS: This retrospective study enrolled mechanically ventilated critically ill who underwent transthoracic echocardiographic examination and CVP monitoring. Echocardiographic indices including tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), and tricuspid lateral annular systolic velocity wave (S') were collected to assess RV function. Patients were then classified into three groups based on their RV function and presence of systemic venous congestion as assessed by inferior vena cava diameter (IVCD) and hepatic vein (HV) Doppler: normal RV function (TAPSE ≥ 17 mm, FAC ≥ 35% and S' ≥9.5 cm/sec), isolated RV dysfunction (TAPSE < 17 mm or FAC < 35% or S' <9.5 cm/sec with IVCD ≤ 20 mm or HV S ≥ D), and RV dysfunction with congestion (TAPSE < 17 mm or FAC < 35% or S' <9.5 cm/sec with IVCD > 20 mm and HV S < D).

RESULTS: A total of 518 patients were enrolled in the study, of whom 301 were categorized in normal RV function group, 164 in isolated RV dysfunction group and 53 in RV dysfunction with congestion group. Receiver operating characteristic analysis revealed a good discriminative ability of CVP for identifying patients with RV dysfunction and congestion(AUC 0.839; 95% CI: 0.795-0.883; p < 0.001). The optimal CVP cutoff was 10 mm Hg, with sensitivity of 79.2%, specificity of 69.4%, negative predictive value of 96.7%, and positive predictive value of 22.8%. A large gray zone existed between 9 mm Hg and 12 mm Hg, encompassing 95 patients (18.3%). For identifying all patients with RV dysfunction, CVP demonstrated a lower discriminative ability (AUC 0.616; 95% CI: 0.567-0.665; p < 0.001). Additionally, the gray zone was even larger, ranging from 5 mm Hg to 12 mm Hg, and included 349 patients (67.4%).

CONCLUSIONS: CVP may be a helpful indicator of acute RV dysfunction patients with systemic venous congestion in mechanically ventilated critically ill, but its accuracy is limited. A CVP less than10 mm Hg can almost rule out RV dysfunction with congestion. In contrast, CVP should not be used to identify general RV dysfunction.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Zhang H, Lian H, Zhang Q, et al. Can central venous pressure help identify acute right ventricular dysfunction in mechanically ventilated critically ill patients? Ann Intensive Care. 2024. PMID: 39031301. doi:10.1186/s13613-024-01352-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。