电阻抗断层成像监测的ARDS区域通气/灌注失匹配绝对值及死腔与分流代偿作用
研究纳入21例接受控制性机械通气的ARDS患者,以侵入性测得的心输出量校准电阻抗断层成像通气/灌注图,比较侵入性分钟通气量/心输出量校准(V'/Q-ABS)、未校准(V'/Q-REL)与仅用电阻抗断层成像数据校正(V'/Q-CORR)三种方法。校准因子与侵入性分钟通气量/心输出量相关(r=0.65,p<0.001),准确度好且无明显偏差;V'/Q-REL高估低V'/Q单元的通气(p=0.013)与灌注(p=0.002)、低估高V'/Q单元的通气(p=0.011)与灌注(p=0.008),V'/Q-CORR则消除所有这些差异(p>0.05)。通气依赖区与分流单元灌注之比(V_D'/Q_SHUNT)越高,PaO2/FiO2越高(r=0.49,p=0.025)、分流分数越低(ρ=-0.59,p=0.005);非依赖区灌注与死腔单元通气之比(Q_ND/V_DS')越高,PEEP越低(ρ=-0.62,p=0.003)、平台压越低(ρ=-0.59,p=0.005);两指数越低与无呼吸机天数越少相关(分别为p=0.05和p=0.03)。
要点
- 在21例控制性机械通气的ARDS患者中,仅用电阻抗断层成像数据的校准因子与侵入性分钟通气量/心输出量相关(r=0.65,p<0.001),准确度好且无明显偏差。
- 与侵入性校准的V'/Q-ABS相比,未校准的V'/Q-REL高估低V'/Q单元的通气(p=0.013)与灌注(p=0.002)、低估高V'/Q单元的通气(p=0.011)与灌注(p=0.008)。
- 仅用电阻抗断层成像数据校正的V'/Q-CORR图消除了与V'/Q-ABS之间的上述所有差异(p>0.05)。
- V_D'/Q_SHUNT越高,PaO2/FiO2越高(r=0.49,p=0.025)、分流分数越低(ρ=-0.59,p=0.005),提示缺氧性肺血管收缩更有效。
- Q_ND/V_DS'越高,PEEP越低(ρ=-0.62,p=0.003)、平台压越低(ρ=-0.59,p=0.005);两指数越低与无呼吸机天数越少相关(p=0.05和p=0.03)。
适用人群与场景
- 21例接受控制性机械通气的急性呼吸窘迫综合征(ARDS)患者。
处置流程与药物剂量
- 以侵入性测得的心输出量作为参照,将电阻抗断层成像获得的分钟通气量/心输出量比值用于校准相对通气/灌注图,得到V'/Q-ABS、V'/Q-REL(不校正)和V'/Q-CORR(仅用电阻抗断层成像数据校正)三种图。
- 计算通气依赖区与分流单元灌注之比(V_D'/Q_SHUNT)作为缺氧性肺血管收缩更有效的指数,计算非依赖区灌注与死腔单元通气之比(Q_ND/V_DS')作为低碳酸性肺血管收缩的指数。
研究设计与关键结果
- 研究类型为电阻抗断层成像校准方法学研究,纳入21例控制性机械通气的ARDS患者;比较V'/Q-ABS、V'/Q-REL与V'/Q-CORR三种区域通气/灌注图。
- 校准因子与侵入性分钟通气量/心输出量相关(r=0.65,p<0.001),准确度好且无明显偏差。
- 与V'/Q-ABS相比,V'/Q-REL高估低V'/Q单元的通气(p=0.013)与灌注(p=0.002)、低估高V'/Q单元的通气(p=0.011)与灌注(p=0.008),并低估不同V'/Q compartment的通气与灌注异质性。
- V'/Q-CORR图消除了与V'/Q-ABS之间的上述所有差异(p>0.05)。
- V_D'/Q_SHUNT越高与PaO2/FiO2越高相关(r=0.49,p=0.025),与分流分数越低相关(ρ=-0.59,p=0.005)。
- Q_ND/V_DS'越高与PEEP越低相关(ρ=-0.62,p=0.003),与平台压越低相关(ρ=-0.59,p=0.005)。
- 两指数(V_D'/Q_SHUNT与Q_ND/V_DS')越低与无呼吸机天数越少相关(p=0.05和p=0.03)。
证据类型、等级与局限
- 证据类型:电阻抗断层成像校准方法学研究(21例ARDS患者)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,仅用电阻抗断层成像数据非侵入性校准的区域通气/灌注图可紧密近似侵入性监测所得结果,可能减少对侵入性校准的依赖。
- 作者认为,分流代偿效率更高可改善氧合,而较低气道压时对死腔代偿的需求较少;代偿机制更有效的患者可能预后更好。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Assessment of regional ventilation/perfusion (V'/Q) mismatch using electrical impedance tomography (EIT) represents a promising advancement for personalized management of the acute respiratory distress syndrome (ARDS). However, accuracy is still hindered by the need for invasive monitoring to calibrate ventilation and perfusion. Here, we propose a non-invasive correction that uses only EIT data and characterized patients with more pronounced compensation of V'/Q mismatch.
METHODS: We enrolled twenty-one ARDS patients on controlled mechanical ventilation. Cardiac output was measured invasively, and ventilation and perfusion were assessed by EIT. Relative V'/Q maps by EIT were calibrated to absolute values using the minute ventilation to invasive cardiac output (MV/CO) ratio (V'/Q-ABS), left unadjusted (V'/Q-REL), or corrected by MV/CO ratio derived from EIT data (V'/Q-CORR). The ratio between ventilation to dependent regions and perfusion reaching shunted units ( V D ' /QSHUNT) was calculated as an index of more effective hypoxic pulmonary vasoconstriction. The ratio between perfusion to non-dependent regions and ventilation to dead space units (QND/ V DS ' ) was calculated as an index of hypocapnic pneumoconstriction.
RESULTS: Our calibration factor correlated with invasive MV/CO (r = 0.65, p < 0.001), showed good accuracy and no apparent bias. Compared to V'/Q-ABS, V'/Q-REL maps overestimated ventilation (p = 0.013) and perfusion (p = 0.002) to low V'/Q units and underestimated ventilation (p = 0.011) and perfusion (p = 0.008) to high V'/Q units. The heterogeneity of ventilation and perfusion reaching different V'/Q compartments was underestimated. V'/Q-CORR maps eliminated all these differences with V'/Q-ABS (p > 0.05). Higher V D ' / Q SHUNT correlated with higher PaO2/FiO2 (r = 0.49, p = 0.025) and lower shunt fraction (ρ = - 0.59, p = 0.005). Higher Q ND / V DS ' correlated with lower PEEP (ρ = - 0.62, p = 0.003) and plateau pressure (ρ = - 0.59, p = 0.005). Lower values of both indexes were associated with less ventilator-free days (p = 0.05 and p = 0.03, respectively).
CONCLUSIONS: Regional V'/Q maps calibrated with a non-invasive EIT-only method closely approximate the ones obtained with invasive monitoring. Higher efficiency of shunt compensation improves oxygenation while compensation of dead space is less needed at lower airway pressure. Patients with more effective compensation mechanisms could have better outcomes.