文献速递复苏、休克与脓毒症心脑血管急症

基于人工智能的床旁超声颈动脉可压缩性评估在心肺复苏中判断自主循环恢复

Artificial intelligence-based evaluation of carotid artery compressibility via point-of-care ultrasound in determining the return of spontaneous circulation during cardiopulmonary resuscitation.
PubMed 文献 · Resuscitation · 2024-07-05
一句话结论前瞻性研究显示,AI系统RealCAC-Net通过床旁超声量化颈动脉可压缩性,判断心脏骤停患者自主循环恢复的分类准确率达0.96。

该研究在韩国急诊科前瞻性纳入成人心脏骤停患者,开发并评估AI系统RealCAC-Net,通过床旁超声图像量化颈动脉可压缩性(CAC)以判断自主循环恢复(ROSC)。系统分三步:TransUNet分割、CAC测量算法改进分割并计算CAC、基于CAC分类(0为圆形,1为高度压缩)。训练集来自161例的11958张图像,测试集来自134例的15080张图像。交叉验证平均Dice相似系数0.90、交并比0.84、分类准确率0.96;测试集分类准确率0.96、F1评分0.97。作者认为RealCAC-Net能精确量化CAC以判断ROSC,未来研究应整合该AI增强超声方法以革新急诊救治。

要点

  • RealCAC-Net通过三步流程(TransUNet分割、CAC测量算法、基于CAC分类0-1)量化颈动脉可压缩性。
  • 训练集为161例的11958张图像,测试集为134例的15080张图像,均来自韩国急诊科成人心脏骤停患者。
  • 交叉验证平均Dice相似系数0.90、交并比0.84、分类准确率0.96。
  • 测试集分类准确率0.96、F1评分0.97,用于识别心脏骤停中的ROSC。
  • 作者认为未来研究应整合该AI增强超声方法以革新急诊救治。

适用人群与场景

  • 成人心脏骤停患者,数据来自韩国急诊科2022至2023年前瞻性研究。

诊断标准与关键阈值

  • 颈动脉可压缩性分类评分从0(表示圆形)到1(表示高度压缩)。

处置流程与药物剂量

  • RealCAC-Net处理图像三步:第一步基于TransUNet的分割;第二步颈动脉可压缩性测量算法改进分割并计算CAC;第三步基于CAC进行分类。

研究设计与关键结果

  • 前瞻性研究,训练集11958张图像来自161例,测试集15080张图像来自134例,开发AI模型RealCAC-Net量化颈动脉可压缩性以判断ROSC。
  • 交叉验证中,应用颈动脉可压缩性测量算法的RealCAC-Net优于基线模型,平均Dice相似系数0.90、交并比0.84、分类准确率0.96。
  • 测试集分类准确率0.96、F1评分0.97,显示在心脏骤停情况下准确识别ROSC的效能。

证据类型、等级与局限

  • 证据类型:前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,未来研究应整合这种AI增强的超声方法以革新急诊救治。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: This study introduces RealCAC-Net, an artificial intelligence (AI) system, to quantify carotid artery compressibility (CAC) and determine the return of spontaneous circulation (ROSC) during cardiopulmonary resuscitation.

METHODS: A prospective study based on data from a South Korean emergency department from 2022 to 2023 investigated carotid artery compressibility in adult patients with cardiac arrest using a novel AI model, RealCAC-Net. The data comprised 11,958 training images from 161 cases and 15,080 test images from 134 cases. RealCAC-Net processes images in three steps: TransUNet-based segmentation, the carotid artery compressibility measurement algorithm for improved segmentation and CAC calculation, and CAC-based classification from 0 (indicating a circular shape) to 1 (indicating high compression). The accuracy of the ROSC classification model was tested using metrics such as the dice similarity coefficient, intersection-over-union, precision, recall, and F1 score.

RESULTS: RealCAC-Net, which applied the carotid artery compressibility measurement algorithm, performed better than the baseline model in cross-validation, with an average dice similarity coefficient of 0.90, an intersection-over-union of 0.84, and a classification accuracy of 0.96. The test set achieved a classification accuracy of 0.96 and an F1 score of 0.97, demonstrating its efficacy in accurately identifying ROSC in cardiac arrest situations.

CONCLUSIONS: RealCAC-Net enabled precise CAC quantification for ROSC determination during cardiopulmonary resuscitation. Future research should integrate this AI-enhanced ultrasound approach to revolutionize emergency care.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Park S, Yoon H, Yeon Kang S, et al. Artificial intelligence-based evaluation of carotid artery compressibility via point-of-care ultrasound in determining the return of spontaneous circulation during cardiopulmonary resuscitation. Resuscitation. 2024. PMID: 38972628. doi:10.1016/j.resuscitation.2024.110302

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。