文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

英国医师-护理人员直升机紧急医疗服务中床旁超声存档系统与治理框架的实施

Implementation of a point-of-care ultrasound archiving system and governance framework in a UK physician-paramedic staffed helicopter emergency medical service.
PubMed 文献 · Scand J Trauma Resusc Emerg Med · 2024-06-03
一句话结论英国HEMS引入POCUS图像云端存档与24小时回顾质控框架后,18.6%接诊患者接受POCUS,96.7%检查接受质控,护理人员与医师图像质量无显著差异且一致性κ>0.85。

该研究回顾性分析了East Anglian Air Ambulance(EAAA)自2020年12月1日引入新型POCUS设备及图像存档系统至2024年1月31日期间的所有接诊患者,纳入有POCUS检查记录者。POCUS图像存档于云端服务器,由EAAA POCUS督导在24小时内回顾,采用5点Likert型量表评定图像质量,记录审核者与临床医师的一致性并反馈扫描技术。结果:共接诊5913例患者,1097例有POCUS图像记录,POCUS使用率18.6%;1061例检查接受质控(96.7%);最常见检查为超声心动图(60%),多在心搏骤停期间进行;25.4%的POCUS检查由护理人员作为主要扫描者;所有检查类型中,医师与护理人员的图像质量无显著差异,审核者与临床医师间一致性高(κ>0.85)。作者认为需进一步研究POCUS的诊断准确性及其对临床结局的影响。

要点

  • EAAA在2020年12月1日至2024年1月31日期间共接诊5913例患者,其中1097例有POCUS图像记录,POCUS使用率为18.6%。
  • 1061例患者检查接受了质量保证(96.7%),图像由EAAA POCUS督导在24小时内回顾,采用5点Likert型量表评定图像质量。
  • 最常见的POCUS检查为超声心动图(60%),主要在心搏骤停期间进行。
  • 25.4%的POCUS检查由护理人员作为主要扫描者;所有检查类型中护理人员与医师的图像质量无显著差异。
  • 审核者与临床医师间一致性高(κ>0.85);作者认为需进一步研究POCUS的诊断准确性及其对临床结局的影响。

适用人群与场景

  • 2020年12月1日至2024年1月31日期间由East Anglian Air Ambulance(EAAA)接诊的所有患者。
  • 纳入标准:有POCUS检查记录的患者;共1097例有POCUS图像记录。

处置流程与药物剂量

  • POCUS图像存档于云端服务器,由EAAA POCUS督导在24小时内回顾。
  • 图像质量采用5点Likert型量表评定,记录审核者与临床医师的一致性,并反馈扫描技术。

研究设计与关键结果

  • 研究类型:回顾性数据库审查;研究期间共接诊5913例患者,1097例有POCUS图像记录,POCUS使用率18.6%。
  • 1061例患者检查接受了质量保证(96.7%)。
  • 最常见的POCUS检查为超声心动图(60%),主要在心搏骤停期间进行。
  • 25.4%的POCUS检查由护理人员作为主要扫描者。
  • 所有检查类型中,医师与护理人员的图像质量无显著差异;审核者与临床医师间一致性高(κ>0.85)。

证据类型、等级与局限

  • 证据类型:回顾性数据库审查(服务评估研究)。
  • 局限:原文未报告局限性;作者在结论中提出需进一步研究POCUS的诊断准确性及利用院前POCUS完善诊断对临床结局的影响。

对床旁实践的改变

  • 作者描述了在HEMS中引入新型POCUS设备、图像存档系统及治理框架后的结局:护理人员作为主要扫描者的检查占四分之一,图像质量与医师相当;几乎所有扫描均接受质量保证,临床医师与审核者间一致性高。
  • 作者认为需进一步研究POCUS的诊断准确性及利用院前POCUS完善诊断对临床结局的影响。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: There has been a rapid expansion in the use of point-of-care ultrasonography (POCUS) by emergency medical services (EMS). However, less than a third of UK EMS utilise imaging archiving for POCUS, and fewer review saved images as part of a clinical governance structure. This paper describes the implementation of a novel image archiving system and a robust clinical governance framework in our UK physician-paramedic staffed helicopter emergency medical service (HEMS).

METHODS: A retrospective database review was conducted of all patients attended by East Anglian Air Ambulance (EAAA) between the introduction of a new POCUS device and image archiving system on 1 December 2020 to 31 January 2024. All patients with recorded POCUS examinations were included. Images from POCUS examinations at EAAA are archived on a cloud-based server, and retrospectively reviewed within 24 h by an EAAA POCUS supervisor. Image quality is graded using a 5-point Likert-type scale, agreement between reviewer and clinician is recorded and feedback is provided on scanning technique. T-tests were used to assess the difference in image quality between physicians and paramedics. Inter-rater reliability between reviewers and clinicians was assessed using Cohen's kappa (κ).

RESULTS: During the study period, 5913 patients were attended by EAAA. Of these, 1097 patients had POCUS images recorded. The prevalence of POCUS during the study period was 18.6%. 1061 patient examinations underwent quality assurance (96.7%). The most common POCUS examination was echocardiography (60%), predominantly during cardiac arrest. The primary scanning clinician was a paramedic in 25.4% of POCUS examinations. Across all examination types; image quality was not significantly different between physicians and paramedics and agreement between reviewers and clinicians was strong (κ > 0.85).

CONCLUSIONS: In this service evaluation study, we have described outcomes following the introduction of a new POCUS device, image archiving system and governance framework in our HEMS. Paramedics were the primary scanning clinician in a quarter of scans, with image quality comparable to physicians. Almost all scans underwent quality assurance and inter-rater reliability was strong between clinicians and reviewers. Further research is required to investigate the diagnostic accuracy of POCUS and to demonstrate the effect of utilising prehospital POCUS to refine diagnosis on clinical outcomes.

来源:Scand J Trauma Resusc Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Aziz S, Edmunds CT, Barratt J, et al. Implementation of a point-of-care ultrasound archiving system and governance framework in a UK physician-paramedic staffed helicopter emergency medical service. Scand J Trauma Resusc Emerg Med. 2024. PMID: 38831372. doi:10.1186/s13049-024-01224-y

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。