一句话结论心脏骤停后>48h至≤7天行头部CT,标准化定性评估及灰白质比(GWR)模型预测不良功能结局特异度均达100%,敏感度中位数30%–41%。

该研究为TTM2试验内的前瞻性国际多中心观察性研究,纳入140例心脏骤停后无意识成人患者,中位年龄68岁(IQR 59–76),76%为男性,75%结局不良。由7名国际评估者盲法按预先发表方案对发病>48h至≤7天的常规头部CT行定性和定量评估,GWR分别经四区(GWR-4)、八区(GWR-8)手动放置及自动化图谱法获得,预设GWR截断值<1.10。标准化定性评估及所有GWR模型预测不良功能结局(mRS 4–6)特异度均为100%(95%CI 90–100),敏感度中位数分别为37%、39%、30%和41%;GWR-8在预测准确性及组内、组间一致性上优于GWR-4。自动化GWR总体预测准确性(AUC 0.84,95%CI 0.77–0.91)与手动GWR无显著差异。

要点

  • 标准化定性评估及所有GWR模型预测不良功能结局(mRS 4–6)特异度均为100%(95%CI 90–100),可可靠用于神经预后判断。
  • 敏感度中位数:标准化定性评估37%、GWR-8 39%、GWR-4 30%、自动化GWR 41%,各方法均存在漏判可能。
  • GWR-8在预测准确性及组内、组间一致性上优于GWR-4。
  • 自动化GWR总体预测准确性(AUC 0.84,95%CI 0.77–0.91)与手动GWR无显著差异。
  • 自动化GWR有望使心脏骤停患者的CT定量神经预后评估在所有中心可及。

适用人群与场景

  • 心脏骤停后无意识的成人患者,头部CT于发病>48h至≤7天获得。
  • 研究纳入的是TTM2试验内的院外心脏骤停患者。

诊断标准与关键阈值

  • 预设GWR截断值<1.10用于预测不良功能结局(mRS 4–6)。
  • GWR-4和GWR-8分别经基底节层面手动放置的四区和八区感兴趣区计算。
  • 自动化GWR采用基于图谱的方法获得。

研究设计与关键结果

  • 前瞻性、国际、多中心观察性研究,嵌套于TTM2试验,纳入140例无意识患者,中位年龄68岁(IQR 59–76),76%为男性,75%结局不良。
  • 7名国际评估者盲法按预先发表方案评估发病>48h至≤7天的常规头部CT。
  • 标准化定性评估及所有GWR模型预测不良功能结局(mRS 4–6)特异度均为100%(95%CI 90–100)。
  • 敏感度中位数:标准化定性评估37%、GWR-8 39%、GWR-4 30%、自动化GWR 41%。
  • GWR-8在预测准确性及组内、组间一致性上优于GWR-4。
  • 自动化GWR总体预测准确性(AUC 0.84,95%CI 0.77–0.91)与手动GWR无显著差异。

证据类型、等级与局限

  • 证据类型:前瞻性、国际、多中心观察性研究(嵌套于TTM2试验)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,标准化定性和定量CT评估是预测心脏骤停后不良功能结局的可靠且可行的方法。
  • 作者认为,自动化GWR有潜力使心脏骤停患者的CT定量神经预后评估在所有治疗中心可及。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: Application of standardised and automated assessments of head computed tomography (CT) for neuroprognostication after out-of-hospital cardiac arrest.

METHODS: Prospective, international, multicentre, observational study within the Targeted Hypothermia versus Targeted Normothermia after out-of-hospital cardiac arrest (TTM2) trial. Routine CTs from adult unconscious patients obtained > 48 h ≤ 7 days post-arrest were assessed qualitatively and quantitatively by seven international raters blinded to clinical information using a pre-published protocol. Grey-white-matter ratio (GWR) was calculated from four (GWR-4) and eight (GWR-8) regions of interest manually placed at the basal ganglia level. Additionally, GWR was obtained using an automated atlas-based approach. Prognostic accuracies for prediction of poor functional outcome (modified Rankin Scale 4-6) for the qualitative assessment and for the pre-defined GWR cutoff < 1.10 were calculated.

RESULTS: 140 unconscious patients were included; median age was 68 years (interquartile range [IQR] 59-76), 76% were male, and 75% had poor outcome. Standardised qualitative assessment and all GWR models predicted poor outcome with 100% specificity (95% confidence interval [CI] 90-100). Sensitivity in median was 37% for the standardised qualitative assessment, 39% for GWR-8, 30% for GWR-4 and 41% for automated GWR. GWR-8 was superior to GWR-4 regarding prognostic accuracies, intra- and interrater agreement. Overall prognostic accuracy for automated GWR (area under the curve [AUC] 0.84, 95% CI 0.77-0.91) did not significantly differ from manually obtained GWR.

CONCLUSION: Standardised qualitative and quantitative assessments of CT are reliable and feasible methods to predict poor functional outcome after cardiac arrest. Automated GWR has the potential to make CT quantification for neuroprognostication accessible to all centres treating cardiac arrest patients.