文献速递消化、代谢与肾脏急症重症综合管理与镇静镇痛

急诊科谵妄检测:病史、体格检查、实验室检查与筛查工具的诊断准确性荟萃分析

Delirium detection in the emergency department: A diagnostic accuracy meta-analysis of history, physical examination, laboratory tests, and screening instruments.
PubMed 文献 · Acad Emerg Med · 2024-05-16
一句话结论急诊老年谵妄筛查中,4AT用于排除谵妄的汇总阴性似然比为0.18,CAM-ICU等工具用于确认谵妄更优但多基于单中心研究。

该研究更新了急诊科谵妄诊断准确性的系统评价,纳入27项研究、针对60岁及以上急诊患者。未发现评估病史或实验室检查准确性的研究;临床整体印象不足以排除谵妄。4AT确认谵妄的汇总阳性似然比为7.5(95%CI 2.7-20.7),排除的汇总阴性似然比为0.18(95%CI 0.09-0.34);AMT-4的汇总阳性似然比为4.3(95%CI 2.4-7.8),低于4AT。基于单项研究,CAM-ICU确认谵妄更优;计算的检测阈值为2%,治疗阈值为11%。

要点

  • 4AT确认谵妄的汇总阳性似然比为7.5(95%CI 2.7-20.7),排除谵妄的汇总阴性似然比为0.18(95%CI 0.09-0.34)。
  • AMT-4确认谵妄的汇总阳性似然比为4.3(95%CI 2.4-7.8),低于4AT;排除的汇总阴性似然比为0.22(95%CI 0.05-1)。
  • 基于单项研究,CAM-ICU是确认谵妄的更优工具,但准确性基于单中心研究。
  • 临床整体印象可准确确认谵妄,但不足以排除谵妄。
  • 计算的检测阈值为2%,治疗阈值为11%。

适用人群与场景

  • 在急诊科接受评估的60岁及以上成人。

诊断标准与关键阈值

  • 谵妄诊断的检测阈值为2%,治疗阈值为11%。

研究设计与关键结果

  • 全文审查55项研究,最终纳入27项分析。
  • 未发现评估病史或实验室分析准确性的研究。
  • 两项研究报告临床医生可准确确认谵妄,但临床整体印象不足以排除谵妄。
  • 三项研究荟萃分析显示,4AT确认谵妄的汇总阳性似然比为7.5(95%CI 2.7-20.7),排除谵妄的汇总阴性似然比为0.18(95%CI 0.09-0.34)。
  • 两项研究荟萃分析显示,AMT-4确认谵妄的汇总阳性似然比为4.3(95%CI 2.4-7.8),低于4AT;排除谵妄的汇总阴性似然比为0.22(95%CI 0.05-1)。
  • 基于一项研究,CAM-ICU是确认谵妄的更优工具。
  • 计算的检测阈值为2%,治疗阈值为11%。

证据类型、等级与局限

  • 系统评价与荟萃分析,纳入27项研究,对每项研究进行偏倚风险评估。
  • CAM-ICU、简短CAM、急诊改良CAM及谵妄分诊筛查工具的准确性基于单中心研究。

对床旁实践的改变

  • 急诊老年谵妄筛查中,4AT拥有最大量的急诊研究基础。
  • 若目标是确认谵妄,CAM-ICU、简短CAM或急诊改良CAM是更优工具,但准确性基于单中心研究。
  • 若目标是排除谵妄,谵妄分诊筛查更优,基于一项单中心研究。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Geriatric emergency department (ED) guidelines emphasize timely identification of delirium. This article updates previous diagnostic accuracy systematic reviews of history, physical examination, laboratory testing, and ED screening instruments for the diagnosis of delirium as well as test-treatment thresholds for ED delirium screening.

METHODS: We conducted a systematic review to quantify the diagnostic accuracy of approaches to identify delirium. Studies were included if they described adults aged 60 or older evaluated in the ED setting with an index test for delirium compared with an acceptable criterion standard for delirium. Data were extracted and studies were reviewed for risk of bias. When appropriate, we conducted a meta-analysis and estimated delirium screening thresholds.

RESULTS: Full-text review was performed on 55 studies and 27 were included in the current analysis. No studies were identified exploring the accuracy of findings on history or laboratory analysis. While two studies reported clinicians accurately rule in delirium, clinician gestalt is inadequate to rule out delirium. We report meta-analysis on three studies that quantified the accuracy of the 4 A's Test (4AT) to rule in (pooled positive likelihood ratio [LR+] 7.5, 95% confidence interval [CI] 2.7-20.7) and rule out (pooled negative likelihood ratio [LR-] 0.18, 95% CI 0.09-0.34) delirium. We also conducted meta-analysis of two studies that quantified the accuracy of the Abbreviated Mental Test-4 (AMT-4) and found that the pooled LR+ (4.3, 95% CI 2.4-7.8) was lower than that observed for the 4AT, but the pooled LR- (0.22, 95% CI 0.05-1) was similar. Based on one study the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) is the superior instrument to rule in delirium. The calculated test threshold is 2% and the treatment threshold is 11%.

CONCLUSIONS: The quantitative accuracy of history and physical examination to identify ED delirium is virtually unexplored. The 4AT has the largest quantity of ED-based research. Other screening instruments may more accurately rule in or rule out delirium. If the goal is to rule in delirium then the CAM-ICU or brief CAM or modified CAM for the ED are superior instruments, although the accuracy of these screening tools are based on single-center studies. To rule out delirium, the Delirium Triage Screen is superior based on one single-center study.

来源:Acad Emerg Med,查看原文。版权归原作者所有。