脓毒症与非脓毒性血管麻痹性休克患者中性粒细胞胞外诱捕网及游离DNA的血浆动力学:前瞻性比较观察性队列研究
该前瞻性观察性队列纳入脓毒症(n=46)和心脏术后(n=30)血管麻痹性休克患者,检测入ICU时(0H)及12H、24H、48H血浆NETs和cfDNA水平,并记录VIS、SOFA评分及机械通气、ICU和住院时间。两组NETs和cfDNA在48小时内均持续升高,脓毒症组时间加权平均浓度更高(NETs中位差0.06[0.02-0.11],P=0.005;cfDNA中位差0.48[0.20-1.02],P<0.001)。VIS与NETs(脓毒症rho=0.3-0.60,P<0.01;心脏术后rho=0.36-0.57,P≤0.01)及cfDNA(脓毒症rho=0.40-0.56,P<0.01;心脏术后rho=0.38-0.47,P<0.05)相关,NETs与SOFA相关,但NETs和cfDNA均未独立关联通气/ICU/住院时间。
要点
- 脓毒症组NETs时间加权平均浓度中位差0.06(0.02-0.11),P=0.005,高于心脏术后组。
- 脓毒症组cfDNA时间加权平均浓度中位差0.48(0.20-1.02),P<0.001,高于心脏术后组。
- VIS与NETs相关:脓毒症rho=0.3-0.60(P<0.01),心脏术后rho=0.36-0.57(P≤0.01)。
- VIS与cfDNA相关:脓毒症rho=0.40-0.56(P<0.01),心脏术后rho=0.38-0.47(P<0.05)。
- NETs与SOFA相关;NETs和cfDNA均未独立关联机械通气、ICU或住院时间。
适用人群与场景
- 因感染性(SEPSIS)或非感染性(心脏术后,CARDIAC)血管麻痹性休克入住ICU的患者。
研究设计与关键结果
- 前瞻性观察性队列研究:脓毒症组n=46,心脏术后组n=30,检测入ICU时(0H)及12H、24H、48H血浆NETs和cfDNA水平。
- 两组NETs和cfDNA在48小时内均持续升高,脓毒症组时间加权平均浓度更高:NETs中位差0.06(0.02-0.11),P=0.005;cfDNA中位差0.48(0.20-1.02),P<0.001。
- VIS与NETs相关:脓毒症rho=0.3-0.60(P<0.01),心脏术后rho=0.36-0.57(P≤0.01)。
- VIS与cfDNA相关:脓毒症rho=0.40-0.56(P<0.01),心脏术后rho=0.38-0.47(P<0.05)。
- NETs与SOFA相关;NETs和cfDNA均未独立关联机械通气、ICU或住院时间。
证据类型、等级与局限
- 证据类型:前瞻性比较观察性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,这些发现提示无论感染性或非感染性病因,NETs释放可能参与血管麻痹性休克的病理生理过程。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Background: The association between neutrophil extracellular traps (NETs) and the requirement for vasopressor and inotropic support in vasoplegic shock is unclear. This study aimed to investigate the dynamics of plasma levels of NETs and cell-free DNA (cfDNA) up to 48 h after the admission to the intensive care unit (ICU) for management of vasoplegic shock of infectious (SEPSIS) or noninfectious (following cardiac surgery, CARDIAC) origin. Methods: This is a prospective, observational study of NETs and cfDNA plasma levels at 0H (admission) and then at 12H, 24H, and 48H in SEPSIS and CARDIAC patients. The vasopressor inotropic score (VIS), the Sequential Organ Failure Assessment (SOFA) score, and time spent with invasive ventilation, in ICU and in hospital, were recorded. Associations between NETs/cfDNA and VIS and SOFA were analyzed by Spearman's correlation (rho), and between NETs/cfDNA and ventilation/ICU/hospitalization times by generalized linear regression. Results: Both NETs and cfDNA remained elevated over 48 h in SEPSIS (n = 46) and CARDIAC (n = 30) patients, with time-weighted average concentrations greatest in SEPSIS (NETs median difference 0.06 [0.02-0.11], P = 0.005; cfDNA median difference 0.48 [0.20-1.02], P < 0.001). The VIS correlated to NETs (rho = 0.3-0.60 in SEPSIS, P < 0.01, rho = 0.36-0.57 in CARDIAC, P ≤ 0.01) and cfDNA (rho = 0.40-0.56 in SEPSIS, P < 0.01, rho = 0.38-0.47 in CARDIAC, P < 0.05). NETs correlated with SOFA. Neither NETs nor cfDNA were independently associated with ventilator/ICU/hospitalization times. Conclusion: Plasma levels of NETs and cfDNA correlated with the dose of vasopressors and inotropes administered over 48 h in patients with vasoplegic shock from sepsis or following cardiac surgery. NETs levels also correlated with organ dysfunction. These findings suggest that similar mechanisms involving release of NETs are involved in the pathophysiology of vasoplegic shock irrespective of an infectious or noninfectious etiology.
参考来源
- Coupland LA, Spiro C, Quah BJ, et al. PLASMA DYNAMICS OF NEUTROPHIL EXTRACELLULAR TRAPS AND CELL-FREE DNA IN SEPTIC AND NONSEPTIC VASOPLEGIC SHOCK: A PROSPECTIVE COMPARATIVE OBSERVATIONAL COHORT STUDY. Shock. 2024. PMID: 38813920. doi:10.1097/SHK.0000000000002396
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。