文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

电阻抗断层成像在ECCO2R下个体化设定呼气末正压中的作用

Contribution of electrical impedance tomography to personalize positive end-expiratory pressure under ECCO2R.
PubMed 文献 · Crit Care · 2024-04-16
一句话结论病例报告提示,ECCO2R期间每次降低潮气量后可用EIT确定兼顾肺复张与过度膨胀的PEEP(本病例<10 cmH2O),作者认为这可能是未来ECCO2R研究的关键要素。

本文为病例报告,描述1例72岁男性COVID-19相关中度ARDS患者入住ICU,在接受体外二氧化碳清除(ECCO2R)期间每次降低潮气量后,用电阻抗断层成像(EIT)确定最佳PEEP值(PEEPEIT,定义为塌陷曲线与过度膨胀曲线的交点)。所确定的PEEPEIT值显著偏低(<10 cmH2O)。与PEEPEIT水平相关的潮气量降低改善了肺顺应性、降低了驱动压并使通气模式更均匀。作者指出,尽管当前随机对照试验显示ECCO2R超保护性通气不改善生存,但通用超保护性通气设置是否适用于所有患者仍有争议;PEEP设置不当可致肺泡塌陷或过度膨胀,可能抵消降低潮气量带来的益处,EIT可实时监测潮气量降低相关的去复张,指导医生在每次降低潮气量后确定最佳PEEP值。

要点

  • 病例为72岁男性COVID-19相关中度ARDS,入住ICU,在ECCO2R期间每次降低潮气量后用EIT确定PEEPEIT(塌陷曲线与过度膨胀曲线的交点)。
  • 所确定的PEEPEIT值显著偏低(<10 cmH2O)。
  • 与PEEPEIT水平相关的潮气量降低改善了肺顺应性、降低了驱动压并使通气模式更均匀。
  • 作者指出,当前随机对照试验显示ECCO2R超保护性通气不改善生存,但通用超保护性通气设置是否适用于所有患者仍有争议。
  • 作者认为,EIT可实时监测潮气量降低相关的去复张,指导医生在每次降低潮气量后确定最佳PEEP值,该做法可能是未来ECCO2R研究的关键要素。

适用人群与场景

  • 1例72岁男性COVID-19相关中度ARDS患者,入住ICU。

诊断标准与关键阈值

  • PEEPEIT定义为塌陷曲线与过度膨胀曲线的交点。

处置流程与药物剂量

  • 在ECCO2R期间每次降低潮气量后启动EIT监测以确定PEEPEIT值;所确定的PEEPEIT值显著偏低(<10 cmH2O)。

研究设计与关键结果

  • 病例报告:1例72岁男性COVID-19相关中度ARDS患者,在ECCO2R期间每次降低潮气量后以EIT确定PEEPEIT(塌陷曲线与过度膨胀曲线的交点),所确定的PEEPEIT值显著偏低(<10 cmH2O)。
  • 与PEEPEIT水平相关的潮气量降低改善了肺顺应性、降低了驱动压并使通气模式更均匀。
  • 作者指出,当前随机对照试验显示ECCO2R超保护性通气不改善生存,但通用超保护性通气设置是否适用于所有患者仍有争议;PEEP设置不当可致肺泡塌陷或过度膨胀,可能抵消降低潮气量带来的益处。

证据类型、等级与局限

  • 证据类型:病例报告( illustrative case)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,EIT可实时监测潮气量降低相关的去复张,指导医生在每次降低潮气量后确定最佳PEEP值。
  • 作者认为,在ECCO2R下使用EIT调整PEEP至兼顾肺复张与过度膨胀的水平,可能是未来ECCO2R研究的关键要素。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Extracorporeal Carbon Dioxide Removal (ECCO2R) is used in acute respiratory distress syndrome (ARDS) patients to facilitate lung-protective ventilatory strategies. Electrical Impedance Tomography (EIT) allows individual, non-invasive, real-time, bedside, radiation-free imaging of the lungs, providing global and regional dynamic lung analyses. To provide new insights for future ECCO2R research in ARDS, we propose a potential application of EIT to personalize End-Expiratory Pressure (PEEP) following each reduction in tidal volume (VT), as demonstrated in an illustrative case. A 72-year-old male with COVID-19 was admitted to the ICU for moderate ARDS. Monitoring with EIT was started to determine the optimal PEEP value (PEEPEIT), defined as the intersection of the collapse and overdistention curves, after each reduction in VT during ECCO2R. The identified PEEPEIT values were notably low (< 10 cmH2O). The decrease in VT associated with PEEPEIT levels resulted in improved lung compliance, reduced driving pressure and a more uniform ventilation pattern. Despite current Randomized Controlled Trials showing that ultra-protective ventilation with ECCO2R does not improve survival, the applicability of universal ultra-protective ventilation settings for all patients remains a subject of debate. Inappropriately set PEEP levels can lead to alveolar collapse or overdistension, potentially negating the benefits of VT reduction. EIT facilitates real-time monitoring of derecruitment associated with VT reduction, guiding physicians in determining the optimal PEEP value after each decrease in tidal volume. This original description of using EIT under ECCO2R to adjust PEEP at a level compromising between recruitability and overdistention could be a crucial element for future research on ECCO2R.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Pequignot B, Combes A, Lescroart M, et al. Contribution of electrical impedance tomography to personalize positive end-expiratory pressure under ECCO2R. Crit Care. 2024. PMID: 38627745. doi:10.1186/s13054-024-04908-0

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。