文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

低呼吸商与机械通气患者高死亡率相关

Low respiratory quotient correlates with high mortality in patients undergoing mechanical ventilation.
PubMed 文献 · Am J Emerg Med · 2024-01-11
一句话结论机械通气患者中,低呼吸商(RQ)与高死亡率相关(存活者0.70 vs 非存活者0.57,P<0.01),可能提示危重患者氧代谢失代偿。

这项前瞻性观察研究在郊区四级教学医院纳入21名受试者(8例心胸术后、7例ICU、3例急诊、3例健康志愿者),其中10例危重患者在急诊和ICU接受代谢测量,6例死亡。使用高保真自动化设备测量摄氧量(VO2)、二氧化碳生成量(VCO2)和呼吸商(RQ)。存活者VO2 282±95 mL/min、VCO2 202±81 mL/min、RQ 0.70±0.10,非存活者分别为240±87 mL/min、140±66 mL/min、0.57±0.08(P分别为0.34、0.10、<0.01)。低RQ与高死亡率相关,可能提示危重患者氧代谢失代偿。

要点

  • 在机械通气危重患者中,非存活者RQ为0.57±0.08,低于存活者的0.70±0.10,差异有统计学意义(P<0.01)。
  • 排除吸入氧浓度(FIO2)<0.5的受试者后,RQ与死亡率的关联仍显著(P<0.05)。
  • VO2存活者282±95 mL/min vs 非存活者240±87 mL/min(P=0.34),VCO2存活者202±81 mL/min vs 非存活者140±66 mL/min(P=0.10),均未达统计学显著。
  • 10例危重患者中6例死亡,代谢测量在急诊和ICU进行,使用高保真自动化设备(精度等效于Douglas袋法)。

适用人群与场景

  • 年龄18岁或以上的健康志愿者和接受机械通气的患者。
  • 研究在郊区四级教学医院的急诊和ICU进行。

研究设计与关键结果

  • 前瞻性观察研究,共纳入21名受试者:8例心胸术后患者、7例ICU患者、3例急诊患者、3例健康志愿者。
  • 其中10例危重患者在急诊和ICU接受代谢测量,6例死亡。
  • 存活者VO2 282±95 mL/min、VCO2 202±81 mL/min、RQ 0.70±0.10;非存活者VO2 240±87 mL/min、VCO2 140±66 mL/min、RQ 0.57±0.08;P值分别为0.34、0.10、<0.01。
  • 排除FIO2<0.5的受试者后,RQ差异仍显著(P<0.05)。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,低RQ与高死亡率相关,可能提示危重患者氧代谢失代偿。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Oxygen consumption (VO2), carbon dioxide generation (VCO2), and respiratory quotient (RQ), which is the ratio of VO2 to VCO2, are critical indicators of human metabolism. To seek a link between the patient's metabolism and pathophysiology of critical illness, we investigated the correlation of these values with mortality in critical care patients.

METHODS: This was a prospective, observational study conducted at a suburban, quaternary care teaching hospital. Age 18 years or older healthy volunteers and patients who underwent mechanical ventilation were enrolled. A high-fidelity automation device, which accuracy is equivalent to the gold standard Douglas Bag technique, was used to measure VO2, VCO2, and RQ at a wide range of fraction of inspired oxygen (FIO2).

RESULTS: We included a total of 21 subjects including 8 post-cardiothoracic surgery patients, 7 intensive care patients, 3 patients from the emergency room, and 3 healthy volunteers. This study included 10 critical care patients, whose metabolic measurements were performed in the ER and ICU, and 6 died. VO2, VCO2, and RQ of survivors were 282 +/- 95 mL/min, 202 +/- 81 mL/min, and 0.70 +/- 0.10, and those of non-survivors were 240 +/- 87 mL/min, 140 +/- 66 mL/min, and 0.57 +/- 0.08 (p = 0.34, p = 0.10, and p < 0.01), respectively. The difference of RQ was statistically significant (p < 0.01) and it remained significant when the subjects with FIO2 < 0.5 were excluded (p < 0.05).

CONCLUSIONS: Low RQ correlated with high mortality, which may potentially indicate a decompensation of the oxygen metabolism in critically ill patients.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Shinozaki K, Yu PJ, Zhou Q, et al. Low respiratory quotient correlates with high mortality in patients undergoing mechanical ventilation. Am J Emerg Med. 2024. PMID: 38301368. doi:10.1016/j.ajem.2024.01.003

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。