文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

高呼气末正压与低呼气末正压对辅助通气中吸气努力强烈急性呼吸窘迫综合征患者的影响:随机交叉试验

High vs Low PEEP in Patients With ARDS Exhibiting Intense Inspiratory Effort During Assisted Ventilation: A Randomized Crossover Trial.
PubMed 文献 · Chest · 2024-01-29
一句话结论中重度ARDS辅助通气患者中,高PEEP(15 cm H2O)对吸气努力(ΔPes)的影响个体间可变,仅当高PEEP增加肺/呼吸系统顺应性时,作者认为可能有助于减轻自发性肺损伤风险。

本研究为随机交叉试验,纳入16例Pao2/Fio2≤200 mm Hg且ΔPes≥10 cm H2O的中重度ARDS患者,随机接受四种通气设置:PEEP 5 cm H2O或PEEP 15 cm H2O,分别联合同步压力支持通气(PSV)或异步压力控制间歇指令通气(PC-IMV)。结果显示高PEEP与低PEEP相比,ΔPes无系统性差异(PSV:中位数20 cm H2O vs 15 cm H2O,P=0.24;PC-IMV:中位数20 vs 19,P=0.67),呼吸系统驱动压、跨肺驱动压、潮气量、肺/胸壁力学及摆动幅度也无差异。高PEEP对ΔPes和驱动压的影响取决于呼吸系统顺应性的变化(r=-0.85,P<0.001;r=-0.75,P<0.001;r=-0.80,P<0.001),且高PEEP导致潮气量向背侧肺区重新分布,降低腹侧动态应变(PSV:中位数0.49 vs 0.96,P=0.003;PC-IMV:中位数0.65 vs 1.14,P=0.002)。作者认为,仅当高PEEP增加肺/呼吸系统顺应性时,可能有助于减轻自发性肺损伤风险。

要点

  • 中重度ARDS辅助通气患者中,高PEEP(15 cm H2O)与低PEEP(5 cm H2O)相比,ΔPes无系统性差异(PSV:中位数20 vs 15 cm H2O,P=0.24;PC-IMV:中位数20 vs 19,P=0.67)。
  • 高PEEP对ΔPes、呼吸系统驱动压和跨肺驱动压的影响取决于呼吸系统顺应性的变化(r=-0.85,P<0.001;r=-0.75,P<0.001;r=-0.80,P<0.001)。
  • 高PEEP导致潮气量向背侧肺区重新分布,降低腹侧动态应变(PSV:中位数0.49 vs 0.96,P=0.003;PC-IMV:中位数0.65 vs 1.14,P=0.002)。
  • PEEP诱导的呼吸系统顺应性变化由其肺成分驱动,并取决于PEEP诱导的肺泡过度膨胀程度(r=-0.66,P=0.006)。
  • 作者认为,仅当高PEEP增加肺/呼吸系统顺应性时,可能有助于减轻自发性肺损伤风险。

适用人群与场景

  • 纳入16例中重度ARDS患者,Pao2/Fio2≤200 mm Hg且ΔPes≥10 cm H2O,在辅助通气下接受研究。
  • 研究场景为辅助通气(PSV同步或PC-IMV异步吸气辅助)。

诊断标准与关键阈值

  • 纳入标准:Pao2/Fio2≤200 mm Hg且ΔPes≥10 cm H2O。
  • 研究设置:PEEP=5 cm H2O或PEEP=15 cm H2O,联合同步PSV或异步PC-IMV。

处置流程与药物剂量

  • 随机交叉试验中,患者接受四种通气设置:PEEP 5 cm H2O或PEEP 15 cm H2O,分别联合同步PSV或异步PC-IMV吸气辅助。
  • 高PEEP(15 cm H2O)对ΔPes和肺应力的影响个体间可变,取决于其对呼吸系统和肺顺应性的影响以及肺泡过度膨胀程度。

研究设计与关键结果

  • 研究类型:随机交叉试验,样本量16例,纳入Pao2/Fio2≤200 mm Hg且ΔPes≥10 cm H2O的中重度ARDS患者。
  • 干预与对照:随机序列四种通气设置(PEEP 5或15 cm H2O × 同步PSV或异步PC-IMV)。
  • 主要终点:ΔPes在高PEEP与低PEEP间无系统性差异(PSV:中位数20 cm H2O,IQR 15-24 vs 中位数15 cm H2O,IQR 13-23,P=0.24;PC-IMV:中位数20,IQR 18-23 vs 中位数19,IQR 17-25,P=0.67)。
  • 关键次要终点:呼吸系统驱动压、跨肺驱动压、潮气量、肺/胸壁力学及摆动幅度在高PEEP与低PEEP间无差异。
  • 高PEEP对ΔPes、呼吸系统驱动压、跨肺驱动压的影响取决于呼吸系统顺应性的变化(r=-0.85,P<0.001;r=-0.75,P<0.001;r=-0.80,P<0.001)。
  • PEEP诱导的呼吸系统顺应性变化由肺成分驱动,取决于肺泡过度膨胀程度(r=-0.66,P=0.006)。
  • 高PEEP导致潮气量向背侧肺区重新分布,降低腹侧动态应变(PSV:中位数0.49,IQR 0.37-0.83 vs 中位数0.96,IQR 0.62-1.56,P=0.003;PC-IMV:中位数0.65,IQR 0.42-1.31 vs 中位数1.14,IQR 0.79-1.52,P=0.002)。
  • 同步和异步吸气辅助期间结果一致。

证据类型、等级与局限

  • 证据类型:随机交叉试验。
  • 试验注册:ClinicalTrials.gov,注册号NCT04241874。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,高PEEP对ΔPes和肺应力的影响个体间可变,取决于肺泡过度膨胀对呼吸系统和肺顺应性的不同影响。
  • 作者认为,仅当高PEEP增加肺/呼吸系统顺应性时,可能有助于减轻自发性肺损伤风险。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Positive end-expiratory pressure (PEEP) can potentially modulate inspiratory effort (ΔPes), which is the major determinant of self-inflicted lung injury.

RESEARCH QUESTION: Does high PEEP reduce ΔPes in patients with moderate-to-severe ARDS on assisted ventilation?

STUDY DESIGN AND METHODS: Sixteen patients with Pao2/Fio2 ≤ 200 mm Hg and ΔPes ≥ 10 cm H2O underwent a randomized sequence of four ventilator settings: PEEP = 5 cm H2O or PEEP = 15 cm H2O + synchronous (pressure support ventilation [PSV]) or asynchronous (pressure-controlled intermittent mandatory ventilation [PC-IMV]) inspiratory assistance. ΔPes and respiratory system, lung, and chest wall mechanics were assessed with esophageal manometry and occlusions. PEEP-induced alveolar recruitment and overinflation, lung dynamic strain, and tidal volume distribution were assessed with electrical impedance tomography.

RESULTS: ΔPes was not systematically different at high vs low PEEP (pressure support ventilation: median, 20 cm H2O; interquartile range (IQR), 15-24 cm H2O vs median, 15 cm H2O; IQR, 13-23 cm H2O; P = .24; pressure-controlled intermittent mandatory ventilation: median, 20; IQR, 18-23 vs median, 19; IQR, 17-25; P = .67, respectively). Similarly, respiratory system and transpulmonary driving pressures, tidal volume, lung/chest wall mechanics, and pendelluft extent were not different between study phases. High PEEP resulted in lower or higher ΔPes, respiratory system driving pressure, and transpulmonary driving pressure according to whether this increased or decreased respiratory system compliance (r = -0.85, P < .001; r = -0.75, P < .001; r = -0.80, P < .001, respectively). PEEP-induced changes in respiratory system compliance were driven by its lung component and were dependent on the extent of PEEP-induced alveolar overinflation (r = -0.66, P = .006). High PEEP caused variable recruitment and systematic redistribution of tidal volume toward dorsal lung regions, thereby reducing dynamic strain in ventral areas (pressure support ventilation: median, 0.49; IQR, 0.37-0.83 vs median, 0.96; IQR, 0.62-1.56; P = .003; pressure-controlled intermittent mandatory ventilation: median, 0.65; IQR, 0.42-1.31 vs median, 1.14; IQR, 0.79-1.52; P = .002). All results were consistent during synchronous and asynchronous inspiratory assistance.

INTERPRETATION: The impact of high PEEP on ΔPes and lung stress is interindividually variable according to different effects on the respiratory system and lung compliance resulting from alveolar overinflation. High PEEP may help mitigate the risk of self-inflicted lung injury solely if it increases lung/respiratory system compliance.

TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT04241874; URL: www.

CLINICALTRIALS: gov.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Bello G, Giammatteo V, Bisanti A, et al. High vs Low PEEP in Patients With ARDS Exhibiting Intense Inspiratory Effort During Assisted Ventilation: A Randomized Crossover Trial. Chest. 2024. PMID: 38295949. doi:10.1016/j.chest.2024.01.040

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。