文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

高气道闭合压与危重机械通气患者呼吸困难及死亡率增加相关

High Airway Occlusion Pressure Is Associated with Dyspnea and Increased Mortality in Critically Ill Mechanically Ventilated Patients.
PubMed 文献 · Am J Respir Crit Care Med · 2024-01-01
一句话结论机械通气患者P0.1>3.5 cm H2O与呼吸困难相关,且独立关联90天死亡率升高与机械通气时间延长。

本研究为法国10个ICU前瞻性队列研究的二次分析,纳入插管超过24小时、可交流的机械通气患者260例,中位通气4天后测量P0.1。多变量线性回归显示,P0.1的独立相关因素为呼吸困难(P=0.037)、呼吸频率(P<0.001)和PaO2(P=0.008)。P0.1>3.5 cm H2O组90天死亡率为33%,1.5–3.5 cm H2O组为19%,<1.5 cm H2O组为17%(P=0.046);校正主要危险因素后,P0.1每升高1 cm H2O与90天死亡率相关(HR 1.19,95%CI 1.04–1.37;P=0.011),并与机械通气时间延长独立相关(HR 1.10,95%CI 1.02–1.19;P=0.016)。作者认为,异常升高的P0.1可能提示呼吸困难,并与更高死亡率和更长机械通气时间相关。

要点

  • 260例插管超过24小时的可交流机械通气患者中,P0.1中位值为1.9(1–3.5)cm H2O,24%的患者P0.1>3.5 cm H2O。
  • P0.1>3.5 cm H2O组90天死亡率为33%,高于1.5–3.5 cm H2O组的19%和<1.5 cm H2O组的17%(P=0.046)。
  • 校正主要危险因素后,P0.1每升高1 cm H2O,90天死亡风险HR为1.19(95%CI 1.04–1.37;P=0.011)。
  • P0.1每升高1 cm H2O与机械通气时间延长独立相关,HR为1.10(95%CI 1.02–1.19;P=0.016)。
  • 多变量线性回归中,与P0.1独立相关的因素为呼吸困难(P=0.037)、呼吸频率(P<0.001)和PaO2(P=0.008)。

适用人群与场景

  • 法国10个ICU中插管超过24小时、可交流的机械通气患者,用于评估呼吸困难。

研究设计与关键结果

  • 研究类型:法国10个ICU前瞻性队列研究的二次分析;样本量260例;中位通气4天后评估。
  • P0.1分布:中位1.9(1–3.5)cm H2O;24%的患者P0.1>3.5 cm H2O,37%在1.5–3.5 cm H2O之间,39%<1.5 cm H2O。
  • 多变量线性回归:与P0.1独立相关的因素为呼吸困难(P=0.037)、呼吸频率(P<0.001)和PaO2(P=0.008)。
  • 90天死亡率:P0.1>3.5 cm H2O组33%,1.5–3.5 cm H2O组19%,<1.5 cm H2O组17%(P=0.046)。
  • 校正主要危险因素后,P0.1与90天死亡率相关:每1 cm H2O的HR为1.19(95%CI 1.04–1.37;P=0.011)。
  • P0.1与机械通气时间延长独立相关:每1 cm H2O的HR为1.10(95%CI 1.02–1.19;P=0.016)。

证据类型、等级与局限

  • 证据类型:前瞻性队列研究的二次分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在接受有创机械通气的患者中,异常升高的P0.1值可能提示呼吸困难,并与更高死亡率和更长机械通气时间相关。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Rationale: Airway occlusion pressure at 100 ms (P0.1) reflects central respiratory drive. Objectives: We aimed to assess factors associated with P0.1 and whether an abnormally low or high P0.1 value is associated with higher mortality and longer duration of mechanical ventilation (MV). Methods: We performed a secondary analysis of a prospective cohort study conducted in 10 ICUs in France to evaluate dyspnea in communicative MV patients. In patients intubated for more than 24 hours, P0.1 was measured with dyspnea as soon as patients could communicate and the next day. Measurements and Main Results: Among 260 patients assessed after a median time of ventilation of 4 days, P0.1 was 1.9 (1-3.5) cm H2O at enrollment, 24% had P0.1 values >3.5 cm H2O, 37% had P0.1 values between 1.5 and 3.5 cm H2O, and 39% had P0.1 values <1.5 cm H2O. In multivariable linear regression, independent factors associated with P0.1 were the presence of dyspnea (P = 0.037), respiratory rate (P < 0.001), and PaO2 (P = 0.008). Ninety-day mortality was 33% in patients with P0.1 > 3.5 cm H2O versus 19% in those with P0.1 between 1.5 and 3.5 cm H2O and 17% in those with P0.1 < 1.5 cm H2O (P = 0.046). After adjustment for the main risk factors, P0.1 was associated with 90-day mortality (hazard ratio per 1 cm H2O, 1.19 [95% confidence interval, 1.04-1.37]; P = 0.011). P0.1 was also independently associated with a longer duration of MV (hazard ratio per 1 cm H2O, 1.10 [95% confidence interval, 1.02-1.19]; P = 0.016). Conclusions: In patients receiving invasive MV, abnormally high P0.1 values may suggest dyspnea and are associated with higher mortality and prolonged duration of MV.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Le Marec J, Hajage D, Decavèle M, et al. High Airway Occlusion Pressure Is Associated with Dyspnea and Increased Mortality in Critically Ill Mechanically Ventilated Patients. Am J Respir Crit Care Med. 2024. PMID: 38319128. doi:10.1164/rccm.202308-1358OC

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。