文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

以呼气末肺容积设定潮气量的可行性:一项初步临床研究

Feasibility of Setting the Tidal Volume Based on End-Expiratory Lung Volume: A Pilot Clinical Study.
PubMed 文献 · Crit Care Explor · 2024-01-16
一句话结论在中重度ARDS患者中,以实测EELV的25%设定潮气量可行,驱动压≤8 cm H2O对应肺应变<0.25。

本研究为生理学前瞻性单中心初步研究,纳入17例中重度ARDS、深度镇静或肌松、接受控制性机械通气的患者,采用洗入洗出技术测量呼气末肺容积(EELV)。研究分三阶段:基线、按应变选择潮气量设定、以该潮气量通气24小时;潮气量按实测EELV减去所施加呼气末正压所致静态应变后的25%计算。76%的患者维持设定潮气量24小时安全可行,3例因需将呼吸频率设为>35次/分以避免呼吸性酸中毒而退出;驱动压是肺应变的满意替代指标,驱动压≤8 cm H2O对应应变<0.25。

要点

  • 中重度ARDS深度镇静或肌松控制通气患者,潮气量按实测EELV减去PEEP所致静态应变后的25%设定。
  • 按此设定潮气量并通气24小时,76%的入组患者安全可行。
  • 3例因需将呼吸频率设为>35次/分以避免呼吸性酸中毒而退出研究。
  • 驱动压是肺应变的满意替代指标,驱动压≤8 cm H2O对应应变<0.25。

适用人群与场景

  • 中重度ARDS、深度镇静或肌松、接受控制性机械通气、且呼吸机能够以洗入洗出技术测量EELV的患者。

诊断标准与关键阈值

  • 潮气量设定:实测EELV减去所施加PEEP所致静态应变后的25%。
  • 驱动压≤8 cm H2O对应肺应变<0.25。

处置流程与药物剂量

  • 研究分三阶段:基线、按应变选择潮气量设定、以应变选择潮气量通气24小时。
  • 潮气量按实测EELV减去所施加PEEP所致静态应变后的25%计算。

红旗征与不能漏的情况

  • 需将呼吸频率设为>35次/分以避免呼吸性酸中毒时,无法维持应变选择潮气量(3例因此退出)。

研究设计与关键结果

  • 生理学前瞻性单中心初步研究,纳入17例中重度ARDS患者,比较各阶段气体交换与呼吸力学。
  • 在潮气量设定阶段,于不同潮气量下测量驱动压与肺应变(潮气量/EELV),评估两者相关性。
  • 维持应变选择潮气量24小时在76%的入组患者中安全可行。
  • 3例因需将呼吸频率设为>35次/分以避免呼吸性酸中毒而退出研究。
  • 驱动压是該人群中肺应变的满意替代指标,驱动压≤8 cm H2O对应应变<0.25。

证据类型、等级与局限

  • 生理学前瞻性单中心初步研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在中重度ARDS患者中基于实际肺大小设定潮气量可行,驱动压是肺应变的可靠替代指标,驱动压≤8 cm H2O对应应变<0.25。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To assess the feasibility of setting the tidal volume (TV) as 25% of the actual aerated lung volume (rather than on ideal body weight) in patients with Acute Respiratory Distress Syndrome (ARDS).

DESIGN: Physiologic prospective single-center pilot study.

SETTING: Medical ICU specialized in the care of patients with ARDS.

PATIENTS: Patients with moderate-severe ARDS deeply sedated or paralyzed, undergoing controlled mechanical ventilation with a ventilator able to measure the end-expiratory lung volume (EELV) with a washin, washout technique.

INTERVENTIONS: Three-phase study (baseline, strain-selected TV setting, ventilation with strain-selected TV for 24 hr). The TV was calculated as 25% of the measured EELV minus the static strain due to the applied positive end-expiratory pressure.

MEASUREMENTS AND MAIN RESULTS: Gas exchanges and respiratory mechanics were measured and compared in each phase. In addition, during the TV setting phase, driving pressure (DP) and lung strain (TV/EELV) were measured at different TVs to assess the correlation between the two measurements. The maintenance of the set strain-selected TV for 24 hours was safe and feasible in 76% of the patients enrolled. Three patients dropped out from the study because of the need to set a respiratory rate higher than 35 breaths per minute to avoid respiratory acidosis. The DP of the respiratory system was a satisfactory surrogate for strain in this population.

CONCLUSIONS: In our population of 17 patients with moderate to severe ARDS, setting TV based on the actual lung size was feasible. DP was a reliable surrogate of strain in these patients, and DP less than or equal to 8 cm H2O corresponded to a strain less than 0.25.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Grassi A, Teggia-Droghi M, Borgo A, et al. Feasibility of Setting the Tidal Volume Based on End-Expiratory Lung Volume: A Pilot Clinical Study. Crit Care Explor. 2024. PMID: 38234589. doi:10.1097/CCE.0000000000001031

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。