文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

限流型与反向触发型呼吸机异步与潮气量及动态跨肺压升高相关

Flow-Limited and Reverse-Triggered Ventilator Dyssynchrony Are Associated With Increased Tidal and Dynamic Transpulmonary Pressure.
PubMed 文献 · Crit Care Med · 2024-01-12
一句话结论在ARDS或ARDS风险患者中,双触发、限流、早期反向触发和早期呼吸机终止呼吸与潮气量、动态跨肺压及跨肺机械能升高相关,PEEP与镇静不改变此关联。

该前瞻性队列分析纳入35例ARDS或ARDS风险因素的医疗ICU患者,分析超过580,000次呼吸,使用连续食管测压和机器学习算法识别10种呼吸类型,用混合效应模型预测每种呼吸机异步的潮气量、动态跨肺压和跨肺机械能。双触发呼吸与潮气量、动态跨肺压及跨肺机械能增加最显著相关,限流、早期反向触发和早期呼吸机终止呼吸也与之显著相关。增加设定潮气量可能与双触发呼吸导致的高容量高能量通气不成比例增加相关,但PEEP和镇静未临床显著改变异步与肺应力应变替代标志物的相互作用。限流呼吸比双触发呼吸常见两倍以上,需进一步研究异步频率与临床结局的相互作用。

要点

  • 双触发呼吸与潮气量、动态跨肺压和跨肺机械能增加最显著相关;限流、早期反向触发和早期呼吸机终止呼吸也显著增加这些指标。
  • 增加设定潮气量可能与双触发呼吸导致的高容量和高能量通气不成比例增加相关。
  • PEEP和镇静(Richmond躁动-镇静评分)未临床显著改变呼吸机异步与肺应力应变替代标志物的相互作用。
  • 限流呼吸比双触发呼吸常见两倍以上,需进一步研究异步频率对临床结局的影响。
  • 研究纳入35例ARDS或ARDS风险因素的医疗ICU患者,分析超过580,000次呼吸,采用连续食管测压和机器学习算法识别异步。

适用人群与场景

  • 纳入医疗ICU的35例急性呼吸窘迫综合征(ARDS)或具有ARDS风险因素的患者,分析超过580,000次呼吸。
  • 研究场景为医疗ICU,患者接受持续食管测压和机械通气。

诊断标准与关键阈值

  • 使用机器学习算法识别10种类型的呼吸机异步。
  • 通过连续食管测压测量动态跨肺压(ΔP L,dyn)和跨肺机械能。
  • 镇静深度采用Richmond躁动-镇静评分(RASS)评估。

研究设计与关键结果

  • 研究类型为前瞻性队列分析,纳入35例ARDS或ARDS风险因素的医疗ICU患者,分析超过580,000次呼吸,无干预。
  • 双触发呼吸与潮气量(V t)、动态跨肺压(ΔP L,dyn)和跨肺机械能增加最显著相关;限流、早期反向触发和早期呼吸机终止呼吸也显著增加V t、ΔP L,dyn和能量。
  • 增加设定V t可能与双触发呼吸导致的高容量和高能量通气不成比例增加相关;PEEP和镇静未临床显著改变呼吸机异步与肺应力应变替代标志物的相互作用。
  • 限流呼吸比双触发呼吸常见两倍以上。

证据类型、等级与局限

  • 证据类型:前瞻性队列分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,双触发、限流、早期反向触发和早期呼吸机终止呼吸与V t、ΔP L,dyn和能量增加相关,需进一步研究呼吸机异步频率对临床结局的影响。
  • 作者指出,限流呼吸比双触发呼吸常见两倍以上,需进一步工作确定异步频率与临床有意义结局改变的相互作用。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Ventilator dyssynchrony may be associated with increased delivered tidal volumes (V t s) and dynamic transpulmonary pressure (ΔP L,dyn ), surrogate markers of lung stress and strain, despite low V t ventilation. However, it is unknown which types of ventilator dyssynchrony are most likely to increase these metrics or if specific ventilation or sedation strategies can mitigate this potential.

DESIGN: A prospective cohort analysis to delineate the association between ten types of breaths and delivered V t , ΔP L,dyn , and transpulmonary mechanical energy.

SETTING: Patients admitted to the medical ICU.

PATIENTS: Over 580,000 breaths from 35 patients with acute respiratory distress syndrome (ARDS) or ARDS risk factors.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Patients received continuous esophageal manometry. Ventilator dyssynchrony was identified using a machine learning algorithm. Mixed-effect models predicted V t , ΔP L,dyn , and transpulmonary mechanical energy for each type of ventilator dyssynchrony while controlling for repeated measures. Finally, we described how V t , positive end-expiratory pressure (PEEP), and sedation (Richmond Agitation-Sedation Scale) strategies modify ventilator dyssynchrony's association with these surrogate markers of lung stress and strain. Double-triggered breaths were associated with the most significant increase in V t , ΔP L,dyn , and transpulmonary mechanical energy. However, flow-limited, early reverse-triggered, and early ventilator-terminated breaths were also associated with significant increases in V t , ΔP L,dyn , and energy. The potential of a ventilator dyssynchrony type to increase V t , ΔP L,dyn , or energy clustered similarly. Increasing set V t may be associated with a disproportionate increase in high-volume and high-energy ventilation from double-triggered breaths, but PEEP and sedation do not clinically modify the interaction between ventilator dyssynchrony and surrogate markers of lung stress and strain.

CONCLUSIONS: Double-triggered, flow-limited, early reverse-triggered, and early ventilator-terminated breaths are associated with increases in V t , ΔP L,dyn , and energy. As flow-limited breaths are more than twice as common as double-triggered breaths, further work is needed to determine the interaction of ventilator dyssynchrony frequency to cause clinically meaningful changes in patient outcomes.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Sottile PD, Smith B, Stroh JN, et al. Flow-Limited and Reverse-Triggered Ventilator Dyssynchrony Are Associated With Increased Tidal and Dynamic Transpulmonary Pressure. Crit Care Med. 2024. PMID: 38214566. doi:10.1097/CCM.0000000000006180

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。