BIS监测下镇痛镇静联合液压耦合颅内压监测在重型颅脑损伤中的应用
研究分两部分:32例重型颅脑损伤术后患者用Codman与液压耦合系统同步测颅内压,两种方法测值无显著差异(11.94±1.76 mmHg vs. 11.88±1.90 mmHg,P=0.882),95%一致性限-4.55~4.68 mmHg,相关良好。另纳入108例随机分为A组(Codman监测,35例)、B组(液压耦合监测,40例)、C组(液压耦合联合BIS指导镇痛镇静,33例)。C组治疗后颅内压显著低于A、B组,肺部感染、癫痫、再手术及6个月预后不良率均显著低于A、B组。液压耦合波形代偿组35例6个月GOS显著高于失代偿组38例。
要点
- 液压耦合与Codman测颅内压无显著差异(11.94±1.76 mmHg vs. 11.88±1.90 mmHg,P=0.882),95%LoA -4.55~4.68 mmHg,全部点落在一致性限内。
- C组(液压耦合+BIS指导镇痛镇静)治疗后颅内压20.94±2.37 mmHg,显著低于A组25.86±3.15 mmHg和B组26.40±3.09 mmHg(均P<0.05)。
- C组肺部感染9.1% vs. A组45.7%、B组42.5%,癫痫3.0% vs. 31.4%、30.0%,再手术3.0% vs. 31.4%、40.0%,6个月预后不良33.3% vs. 65.7%、65.0%(均P<0.017)。
- 液压耦合波形代偿组35例6个月GOS 4.03±1.18,显著高于失代偿组38例2.39±1.50(t=5.153,P<0.001)。
- 三组脑脊液引流时间、颅内压监测时间、ICU停留时间及颅内感染、颅内再出血、外伤性脑积水、脑脊液漏、意外拔管等并发症发生率无显著差异(P>0.05或P>0.017)。
适用人群与场景
- 第一部分:2020年12月至2021年7月湖州市第一人民医院ICU收治的32例开颅术后重型颅脑损伤患者,前瞻性自身对照平行对照研究。
- 第二部分:2021年8月至2022年8月湖州市第一人民医院ICU收治的108例重型颅脑损伤患者,前瞻性随机对照研究,按随机数字表法分为3组。
诊断标准与关键阈值
- 液压耦合波形分组:P1=P2波或P2、P3波低平为代偿组;圆波或P2>P1波为失代偿组。
处置流程与药物剂量
- 所有患者均接受脑外科术后常规治疗。
- A组(35例):用Codman监测系统监测颅内压。
- B组(40例):用液压耦合监测系统监测颅内压。
- C组(33例):用液压耦合监测系统监测颅内压,并以BIS指导镇痛镇静。
研究设计与关键结果
- 第一部分前瞻性自身对照平行对照研究:32例重型颅脑损伤患者,Codman与液压耦合系统测颅内压无显著差异(mmHg:11.94±1.76 vs. 11.88±1.90,t=0.150,P=0.882;1 mmHg≈0.133 kPa),Blan-altman分析95%一致性限-4.55~4.68 mmHg,全部点落在95%LoA内,提示两种方法相关性好。
- 第二部分前瞻性随机对照研究:108例分为A组35例、B组40例、C组33例;三组脑脊液引流时间、颅内压监测时间、ICU停留时间及颅内感染、颅内再出血、外伤性脑积水、脑脊液漏、意外拔管等并发症发生率无显著差异(P>0.05或P>0.017)。
- C组治疗后颅内压显著低于A组和B组(mmHg:20.94±2.37 vs. 25.86±3.15、26.40±3.09,均P<0.05)。
- C组肺部感染(9.1% vs. 45.7%、42.5%)、癫痫(3.0% vs. 31.4%、30.0%)、再手术(3.0% vs. 31.4%、40.0%)及术后6个月预后不良(33.3% vs. 65.7%、65.0%)均显著低于A组和B组(均P<0.017)。
- 按液压耦合波形,代偿组35例术后6个月GOS显著高于失代偿组38例(4.03±1.18 vs. 2.39±1.50,t=5.153,P<0.001)。
证据类型、等级与局限
- 证据类型:前瞻性自身对照平行对照研究(第一部分)及前瞻性随机对照研究(第二部分)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 液压耦合颅内压监测系统测颅内压准确性和一致性良好,能比传统颅内压监测方法更好地显示颅内压波形变化,对预后评估有更好的预测价值,作者认为可替代Codman监测以准确指导临床工作。
- 作者认为,BIS监测下镇痛镇静联合液压耦合颅内压监测可有效降低颅内压、减少并发症发生率并改善预后,具有较高临床应用价值。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the clinical value of analgesia and sedation under bispectral index (BIS) monitoring combined with hydraulic coupled intracranial pressure (ICP) monitoring in severe craniocerebral injury (sTBI).
METHODS: (1) A prospective self-controlled parallel control study was conducted. A total of 32 patients with sTBI after craniotomy admitted to the intensive care unit (ICU) of the First People's Hospital of Huzhou from December 2020 to July 2021 were selected as the research objects. ICP was monitored by Codman monitoring system and hydraulically coupled monitoring system, and the difference and correlation between them were compared. (2) A prospective randomized controlled study was conducted. A total of 108 sTBI patients admitted to the ICU of the First People's Hospital of Huzhou from August 2021 to August 2022 were selected patients were divided into 3 groups according to the random number table method. All patients were given routine treatment after brain surgery. On this basis, the ICP values of the patients in group A (35 cases) were monitored by Codman monitoring system, the ICP values of the patients in group B (40 cases) were monitored by hydraulic coupling monitoring system, and the ICP values of the patients in group C (33 cases) were monitored combined with hydraulic coupling monitoring system, and the analgesia and sedation were guided by BIS. The ICP after treatment, cerebrospinal fluid drainage time, ICP monitoring time, ICU stay time, complications and Glasgow outcome score (GOS) at 6 months after surgery were compared among the 3 groups. In addition, patients in group B and group C were further grouped according to the waveforms. If P1 = P2 wave or P2 and P3 wave were low, they were classified as compensatory group. If the round wave or P2 > P1 wave was defined as decompensated group, the GOS scores of the two groups at 6 months after operation were compared.
RESULTS: (1) There was no significant difference in ICP values measured by Codman monitoring system and hydraulic coupling monitoring system in the same patient (mmHg: 11.94±1.76 vs. 11.88±1.90, t = 0.150, P = 0.882; 1 mmHg≈0.133 kPa). Blan-altman analysis showed that the 95% consistency limit (95%LoA) of ICP values measured by the two methods was -4.55 to 4.68 mmHg, and all points fell within 95%LoA, indicating that the two methods had a good correlation. (2) There were no significant differences in cerebrospinal fluid drainage time, ICP monitoring time, ICU stay time, and incidence of complications such as intracranial infection, intracranial rebleeding, traumatic hydrocephalus, cerebrospinal fluid leakage, and accidental extubation among the 3 groups of sTBI patients (P > 0.05 or P > 0.017). The ICP value of group C after treatment was significantly lower than that of group A and group B (mmHg: 20.94±2.37 vs. 25.86±3.15, 26.40±3.09, all P < 0.05), the incidence of pulmonary infection (9.1% vs. 45.7%, 42.5%), seizure (3.0% vs. 31.4%, 30.0%), reoperation (3.0% vs. 31.4%, 40.0%), and poor prognosis 6 months after operation (33.3% vs. 65.7%, 65.0%) were significantly lower than those in group A and group B (all P < 0.017). According to the hydraulic coupling waveform, GOS scores of 35 patients in the compensated group were significantly higher than those of 38 patients in the decompensated group 6 months after operation (4.03±1.18 vs. 2.39±1.50, t = 5.153, P < 0.001).
CONCLUSIONS: The hydraulic coupled intracranial pressure monitoring system has good accuracy and consistency in measuring ICP value, and it can better display ICP waveform changes than the traditional ICP monitoring method, and has better prediction value for prognosis evaluation, which can replace Codman monitoring to accurately guide clinical work. In addition, analgesia and sedation under BIS monitoring combined with hydraulic coupled ICP monitoring can effectively reduce ICP, reduce the incidence of complications, and improve the prognosis, which has high clinical application value.
参考来源
- Cai Y, Dong Z, Zhong X, et al. [Application of analgesia and sedation under BIS monitoring combined with hydraulic coupling intracranial pressure monitoring in severe craniocerebral injury]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2023. PMID: 38149389. doi:10.3760/cma.j.cn121430-20231023-00171
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。