文献速递重症综合管理与镇静镇痛

三级医疗重症监护病房心脏床旁超声的诊断准确性

Diagnostic Accuracy of Cardiac Point-of-Care Ultrasound in a Tertiary Medical Intensive Care Unit.
PubMed 文献 · Crit Care Explor · 2023-12-20
一句话结论心脏床旁超声评估左室和右室收缩功能、心包积液和右室大小可靠,但检测瓣膜反流能力有限。

该研究回顾性分析了美国大型学术医疗中心医疗ICU中504对心脏床旁超声(CCE)与24小时内进行的超声心动图(TTE)检查。CCE由fellow执行并由主治医师审核。结果显示,CCE检测左室和右室收缩功能障碍、心包积液和右室大小的kappa值为0.60-0.74,敏感性和特异性为0.85-0.99;而检测二尖瓣、三尖瓣和主动脉瓣反流时,60-70%的CCE检查无法诊断,kappa值为0.32-0.42。研究表明CCE在评估心室功能和心包积液方面可靠,但在瓣膜反流检测方面可能有限。

要点

  • CCE检测左室和右室收缩功能障碍、心包积液的敏感性和特异性为0.85-0.99,kappa值0.60-0.74。
  • CCE检测右室扩张的kappa值为0.59,敏感性0.71,特异性0.85。
  • CCE检测二尖瓣、三尖瓣或主动脉瓣反流时,60-70%的检查无法诊断,而TTE为20-30%。
  • CCE检测瓣膜反流的kappa值为0.32-0.42,一致性较低。

适用人群与场景

  • 美国大型学术医疗中心医疗ICU的患者,CCE检查由fellow执行并由主治医师审核,并与24小时内进行的TTE比较。

研究设计与关键结果

  • 研究为回顾性队列研究,分析了504对CCE和TTE检查。
  • CCE检测左室和右室收缩功能障碍、心包积液和右室大小的kappa值为0.60-0.74,敏感性和特异性为0.85-0.99。
  • CCE检测右室扩张的kappa值为0.59,敏感性0.71,特异性0.85。
  • CCE检测二尖瓣、三尖瓣或主动脉瓣反流时,60-70%的检查无法诊断,而TTE为20-30%;kappa值为0.32-0.42。

证据类型、等级与局限

  • 证据类型:回顾性研究;局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为CCE是评估左室和右室收缩功能、心包积液和右室大小的可靠工具。
  • 作者认为CCE在检测二尖瓣、三尖瓣或主动脉瓣反流方面可能有限。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Critical care echocardiography (CCE) is a useful tool for managing critically ill patients in intensive care. However, concerns exist regarding the accuracy of CCE examinations because of operator dependence. We sought to evaluate the accuracy of CCE examinations compared with cardiology-performed transthoracic echocardiogram (TTE).

DESIGN SETTING AND SUBJECTS: We retrospectively reviewed charts of patients in a medical ICU in a large academic medical center in the United States. We compared CCE examinations performed by a fellow and reviewed by a staff physician between May 5, 2020, and December 31, 2021, to TTE obtained within 24 hours of the CCE examination.

INTERVENTION MEASUREMENTS AND MAIN RESULTS: We developed a standardized process for documentation of all CCE examinations performed in the medical ICU. We assessed agreement (kappa statistic), sensitivity and specificity of CCE examination compared with TTE. Features included left ventricle (LV) systolic function, right ventricle (RV) size, RV systolic function, pericardial effusion, mitral insufficiency, tricuspid insufficiency, and aortic insufficiency. The study analyzed 504 pairs of CCE and TTE examinations. Kappa statistics for detecting LV and RV systolic dysfunction, pericardial effusion, and RV size ranged from 0.60 to 0.74. CCE showed high sensitivity and specificity for detecting LV and RV systolic dysfunction and pericardial effusion, with values ranging from 0.85 to 0.99. The kappa statistic for detecting RV dilation was 0.59, with a sensitivity of 0.71 and a specificity of 0.85. In contrast, CCE examinations were nondiagnostic for mitral, tricuspid, or aortic insufficiency in 60-70% of cases, whereas TTE examinations were nondiagnostic in 20-30% of cases. Kappa statistics for mitral, tricuspid, and aortic insufficiency ranged from 0.32 to 0.42.

CONCLUSIONS: CCE is a reliable tool for assessing LV and RV systolic function, pericardial effusion, and RV size. However, CCE may be limited in its ability to detect mitral, tricuspid, or aortic insufficiency.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Fox S, Alwakeel M, Wang X, et al. Diagnostic Accuracy of Cardiac Point-of-Care Ultrasound in a Tertiary Medical Intensive Care Unit. Crit Care Explor. 2023. PMID: 38131017. doi:10.1097/CCE.0000000000001019

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。