文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

颈动脉超声评估低潮气量保留自主呼吸机械通气患者的容量反应性

CAROTID ARTERY ULTRASOUND FOR ASSESSING FLUID RESPONSIVENESS IN PATIENTS UNDERGOING MECHANICAL VENTILATION WITH LOW TIDAL VOLUME AND PRESERVED SPONTANEOUS BREATHING.
PubMed 文献 · Shock · 2023-12-12
一句话结论在潮气量<8 mL/kg且保留自主呼吸的机械通气患者中,补液后颈动脉校正血流时间变化(ΔFTc bolus)可预测容量反应性,其预测性能优于颈动脉峰值流速呼吸变异(ΔV peak bolus)。

本研究纳入43例急性循环衰竭的机械通气患者,潮气量<8 mL/kg预测体重且保留自主呼吸,共进行60次液体挑战(250 mL晶体液)。以无创心输出量监测的每搏量指数增加≥10%定义容量反应性。容量反应阳性组(n=35)与阴性组(n=25)的ΔFTc bolus和ΔV peak bolus差异有统计学意义。ΔFTc bolus和ΔV peak bolus预测容量反应性的ROC曲线下面积分别为0.935和0.750,最佳截断值分别为0.725(敏感度97.1%,特异度84%)和4.21%(敏感度65.7%,特异度80%)。结论提示ΔFTc bolus和ΔV peak bolus可预测容量反应性,且ΔFTc bolus预测性能更优。

要点

  • 在潮气量<8 mL/kg且保留自主呼吸的机械通气急性循环衰竭患者中,补液后ΔFTc bolus预测容量反应性的ROC曲线下面积为0.935,最佳截断值0.725(敏感度97.1%,特异度84%)。
  • 补液后ΔV peak bolus预测容量反应性的ROC曲线下面积为0.750,最佳截断值4.21%(敏感度65.7%,特异度80%),预测性能低于ΔFTc bolus。
  • 容量反应阳性组(n=35)与阴性组(n=25)的ΔFTc bolus和ΔV peak bolus差异有统计学意义。
  • ΔFTc bolus和ΔV peak bolus与补液后每搏量指数相对增加相关(r=0.5296,P<0.0001;r=0.3175,P=0.0135)。
  • 多因素logistic回归分析显示ΔFTc bolus和ΔV peak bolus与容量反应性显著相关。

适用人群与场景

  • 急性循环衰竭的机械通气患者,潮气量<8 mL/kg预测体重,且保留自主呼吸。

诊断标准与关键阈值

  • 容量反应性定义:液体挑战(250 mL晶体液)后无创心输出量监测的每搏量指数增加≥10%。
  • ΔFTc bolus预测容量反应性的最佳截断值为0.725(敏感度97.1%,特异度84%)。
  • ΔV peak bolus预测容量反应性的最佳截断值为4.21%(敏感度65.7%,特异度80%)。

处置流程与药物剂量

  • 给予250 mL晶体液进行液体挑战,测量补液前后颈动脉校正血流时间、ΔV peak及血流动力学数据。

研究设计与关键结果

  • 研究纳入43例急性循环衰竭的机械通气患者,共进行60次液体挑战;容量反应阳性组n=35,阴性组n=25。
  • ΔFTc bolus和ΔV peak bolus在容量反应阳性组与阴性组间差异有统计学意义。
  • ΔFTc bolus与补液后每搏量指数相对增加相关(r=0.5296,P<0.0001);ΔV peak bolus与补液后每搏量指数相对增加相关(r=0.3175,P=0.0135)。
  • 多因素logistic回归分析显示ΔFTc bolus和ΔV peak bolus与容量反应性显著相关。
  • ΔFTc bolus和ΔV peak bolus预测容量反应性的ROC曲线下面积分别为0.935和0.750。
  • ΔFTc bolus最佳截断值0.725(敏感度97.1%,特异度84%);ΔV peak bolus最佳截断值4.21%(敏感度65.7%,特异度80%)。
  • 结论:在潮气量<8 mL/kg且保留自主呼吸的机械通气患者中,ΔFTc bolus和ΔV peak bolus可预测容量反应性,ΔFTc bolus预测性能优于ΔV peak bolus。

证据类型、等级与局限

  • 研究类型:摘要未明确说明研究设计类型。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对于潮气量<8 mL/kg且保留自主呼吸的机械通气急性循环衰竭患者,补液后测量ΔFTc bolus和ΔV peak bolus可预测容量反应性;ΔFTc bolus预测性能优于ΔV peak bolus。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Objective : This study aimed to investigate whether changes in carotid artery corrected flow time (ΔFTc bolus ) and carotid artery peak flow velocity respiratory variation (Δ V peak bolus ) induced by the fluid challenge could reliably predict fluid responsiveness in mechanically ventilated patients with a tidal volume < 8 mL/kg Predicted Body Weight while preserving spontaneous breathing. Methods : Carotid artery corrected flow time, Δ V peak, and hemodynamic data were measured before and after administration of 250 mL crystalloids. Fluid responsiveness was defined as a 10% or more increase in stroke volume index as assessed by noninvasive cardiac output monitoring after the fluid challenge. Results : A total of 43 patients with acute circulatory failure were enrolled in this study. Forty-three patients underwent a total of 60 fluid challenges. The ΔFTc bolus and Δ V peak bolus showed a significant difference between the fluid responsiveness positive group (n = 35) and the fluid responsiveness negative group (n = 25). Spearman correlation test showed that ΔFTc bolus and Δ V peak bolus with the relative increase in stroke volume index after fluid expansion ( r = 0.5296, P < 0.0001; r = 0.3175, P = 0.0135). Multiple logistic regression analysis demonstrated that ΔFTc bolus and Δ V peak bolus were significantly correlated with fluid responsiveness in patients with acute circulatory failure. The areas under the receiver operating characteristic curves of ΔFTc bolus and Δ V peak bolus for predicting fluid responsiveness were 0.935 and 0.750, respectively. The optimal cutoff values of ΔFTc bolus and Δ V peak bolus were 0.725 (sensitivity = 97.1%, specificity = 84%) and 4.21% (sensitivity = 65.7%, specificity = 80%), respectively. Conclusion : In mechanically ventilated patients with a tidal volume < 8 mL/kg while preserving spontaneous breathing, ΔFTc bolus and Δ V peak bolus could predict fluid responsiveness. The predictive performance of ΔFTc bolus was superior to Δ V peak bolus .

来源:Shock,查看原文。版权归原作者所有。

参考来源

  1. Zhou K, Ran S, Guo Y, et al. CAROTID ARTERY ULTRASOUND FOR ASSESSING FLUID RESPONSIVENESS IN PATIENTS UNDERGOING MECHANICAL VENTILATION WITH LOW TIDAL VOLUME AND PRESERVED SPONTANEOUS BREATHING. Shock. 2023. PMID: 38117132. doi:10.1097/SHK.0000000000002288

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。