多中心质量改进项目前后儿童呼吸机相关事件的变化
该多中心质量改进研究获取2017至2020年北美95家儿童医院解决方案患者安全(SPS)网络医院新生儿、儿科及心脏ICU机械通气患者数据,2018年7月向自愿参与的医院分发包含多学科表观原因分析、每日讨论拔管准备度、每日讨论液体平衡目标3项测试因素的质量改进集束。21家Pioneer队列医院中12家(57%)为可靠报告者,PedVAE率从1.9降至1.4例/1000呼吸机日(绝对率差-0.6;95%CI -0.5至-0.7;P<.001);33家可靠报告但未实施集束的医院无显著变化。12家中3家可靠执行每日讨论拔管准备度的医院PedVAE率从2.6降至1.2例/1000呼吸机日(绝对率差-1.4;95%CI -1.0至-1.7;P<.001),其余9家未实施该讨论的医院无下降。作者认为寻求减少PedVAE的ICU团队应将每日讨论拔管准备度纳入晨间查房。
要点
- 95家SPS网络医院中21家为Pioneer队列、74家为非Pioneer队列;仅12家Pioneer医院(57%)和33家非Pioneer医院(45%)为可靠结局报告者。
- 12家可靠报告的Pioneer医院PedVAE率从1.9降至1.4例/1000呼吸机日(绝对率差-0.6;95%CI -0.5至-0.7;P<.001)。
- 33家可靠提交PedVAE率但未实施集束的医院PedVAE率无显著变化。
- 12家中3家可靠执行每日讨论拔管准备度的医院PedVAE率从2.6降至1.2例/1000呼吸机日(绝对率差-1.4;95%CI -1.0至-1.7;P<.001),其余9家未实施该讨论的医院无下降。
- 作者认为,寻求减少PedVAE的ICU团队应将每日讨论拔管准备度纳入晨间查房。
适用人群与场景
- 2017至2020年在北美95家参与儿童医院解决方案患者安全(SPS)网络医院的新生儿、儿科及心脏ICU接受机械通气并接受治疗的患者。
- 分析聚焦于可靠提交PedVAE率数据的医院,即截至2020年5月31日基线期和基线后期至少80%时间段提交结局数据的医院。
诊断标准与关键阈值
- PedVAE定义为基线稳定或改善期后氧合持续恶化。
处置流程与药物剂量
- 质量改进集束包含3项测试因素:多学科表观原因分析、每日讨论拔管准备度、每日讨论液体平衡目标;该集束于2018年7月分发给自愿参与SPS网络指导下PedVAE预防协作项目的医院亚组。
研究设计与关键结果
- 多中心质量改进研究,获取2017至2020年95家SPS网络医院新生儿、儿科及心脏ICU机械通气患者数据,数据分析于2021年9月至2023年4月进行。
- 95家报告PedVAE数据的SPS网络医院中,21家归入Pioneer队列、74家归入非Pioneer队列;21家Pioneer医院中仅12家(57%)和74家非Pioneer医院中33家(45%)被视为结局数据可靠报告者。
- 12家可靠报告的Pioneer医院PedVAE率从1.9降至1.4例/1000呼吸机日(绝对率差-0.6;95%CI -0.5至-0.7;P<.001)。
- 33家可靠提交PedVAE率但未实施集束的医院PedVAE率无显著变化。
- 12家中3家可靠执行每日讨论拔管准备度的医院PedVAE率从2.6降至1.2例/1000呼吸机日(绝对率差-1.4;95%CI -1.0至-1.7;P<.001);其余9家未实施该讨论的医院无下降。
证据类型、等级与局限
- 证据类型:多中心质量改进研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,寻求减少PedVAE的ICU团队应将每日讨论拔管准备度纳入晨间查房。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
IMPORTANCE: Pediatric ventilator-associated events (PedVAEs, defined as a sustained worsening in oxygenation after a baseline period of stability or improvement) are useful for surveillance of complications from mechanical ventilation. It is unclear whether interventions to mitigate known risk factors can reduce PedVAE rates.
OBJECTIVE: To assess whether adherence to 1 or more test factors in a quality improvement bundle was associated with a reduction in PedVAE rates.
DESIGN, SETTING, AND PARTICIPANTS: This multicenter quality improvement study obtained data from 2017 to 2020 for patients who were mechanically ventilated and cared for in neonatal, pediatric, and cardiac intensive care units (ICUs). These ICUs were located in 95 hospitals participating in the Children's Hospitals' Solutions for Patient Safety (SPS) network in North America. Data analyses were performed between September 2021 and April 2023.
INTERVENTION: A quality improvement bundle consisted of 3 test factors: multidisciplinary apparent cause analysis, daily discussion of extubation readiness, and daily discussion of fluid balance goals. This bundle was distributed to a subgroup of hospitals that volunteered to participate in a collaborative PedVAE prevention initiative under the SPS network guidance in July 2018.
MAIN OUTCOMES AND MEASURES: Each SPS network hospital submitted monthly PedVAE rates from January 1, 2017, to May 31, 2020, and test factor data were submitted from July 1, 2018, to May 31, 2020. Analyses focused on hospitals that reliably submitted PedVAE rate data, defined as outcomes data submission through May 31, 2020, for at least 80% of the baseline and postbaseline periods.
RESULTS: Of the 95 hospitals in the SPS network that reported PedVAE data, 21 were grouped in the Pioneer cohort and 74 in the non-Pioneer cohort. Only 12 hospitals (57%) from the 21 Pioneer hospitals and 33 (45%) from the 74 non-Pioneer hospitals were considered to be reliable reporters of outcome data. Among the 12 hospitals, the PedVAE rate decreased from 1.9 to 1.4 events per 1000 ventilator days (absolute rate difference, -0.6; 95% CI, -0.5 to -0.7; P < .001). No significant change in the PedVAE rate was seen among the 33 hospitals that reliably submitted PedVAE rates but did not implement the bundle. Of the 12 hospitals, 3 that reliably performed daily discussion of extubation readiness had a decrease in PedVAE rate from 2.6 to 1.2 events per 1000 ventilator days (absolute rate difference, -1.4; 95% CI, -1.0 to -1.7; P < .001), whereas the other 9 hospitals that did not implement this discussion did not have a decrease.
CONCLUSIONS AND RELEVANCE: This study found that a multicenter quality improvement intervention targeting PedVAE risk factors was associated with a substantial reduction in the rate of PedVAEs in hospital ICUs. The findings suggest that ICU teams seeking to reduce PedVAEs incorporate daily discussion of extubation readiness during morning rounds.
参考来源
- Wu AG, Madhavan G, Deakins K, et al. Pediatric Ventilator-Associated Events Before and After a Multicenter Quality Improvement Initiative. JAMA Netw Open. 2023. PMID: 38060226. doi:10.1001/jamanetworkopen.2023.46545
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。