文献速递重症综合管理与镇静镇痛呼吸衰竭与机械通气

静脉-动脉体外膜氧合期间的氧合:生理学、当前证据与氧滴定实用方法

Oxygenation During Venoarterial Extracorporeal Membrane Oxygenation: Physiology, Current Evidence, and a Pragmatic Approach to Oxygen Titration.
PubMed 文献 · Crit Care Med · 2023-12-07
一句话结论外周静脉-动脉ECMO患者高氧常见且与院内死亡相关,实用方法是目标右桡动脉血氧饱和度94-98%,选择性患者调节空氧混合器使氧合器后PaO2达150-300 mm Hg。

本叙述性综述检索PubMed、SCOPUS、Medline和Google Scholar,纳入观察性与干预性研究及体外生命支持组织指南,总结静脉-动脉ECMO期间影响全身氧合的通路与患者因素。ECMO回路氧合贡献主要由ECMO血流量决定,自身氧合贡献来自自身心输出量和残余呼吸功能,两者交互(如差异性低氧)及呼吸支持、氧运输参数共同调节氧暴露。高氧定义多样,最常用PaO2>150 mm Hg,严重高氧(原文写作PaO2>300 mm Hg)见于20%。早期严重高氧及累积高氧暴露与院内死亡相关,在静脉-动脉ECMO和体外心肺复苏中校正疾病严重度后仍相关。实用方法为外周静脉-动脉ECMO目标右桡动脉血氧饱和度94-98%,选择性患者通过空氧混合器调节吸入氧分数使氧合器后PaO2达150-300 mm Hg。

要点

  • 外周静脉-动脉ECMO患者高氧常见,最常用定义为PaO2>150 mm Hg,严重高氧(原文写作PaO2>300 mm Hg)见于20%。
  • 早期严重高氧及累积高氧暴露与院内死亡相关,在静脉-动脉ECMO和体外心肺复苏中校正疾病严重度后仍相关。
  • 实用氧滴定方法:目标右桡动脉血氧饱和度94-98%。
  • 选择性患者通过空氧混合器调节吸入氧分数,目标氧合器后PaO2 150-300 mm Hg。
  • ECMO回路对全身氧合的贡献主要由ECMO血流量决定,自身贡献来自自身心输出量和残余呼吸功能。

适用人群与场景

  • 接受外周静脉-动脉体外膜氧合(ECMO)的患者。

诊断标准与关键阈值

  • 高氧定义多样,最常用为PaO2>150 mm Hg。
  • 严重高氧原文写作PaO2>300 mm Hg。
  • 实用方法目标:右桡动脉血氧饱和度94-98%。
  • 选择性患者目标:氧合器后PaO2 150-300 mm Hg。

处置流程与药物剂量

  • 目标右桡动脉血氧饱和度94-98%。
  • 在选择性患者中,通过空氧混合器调节吸入氧分数,目标氧合器后PaO2 150-300 mm Hg。

研究设计与关键结果

  • 本综述检索PubMed、SCOPUS、Medline和Google Scholar,纳入所有探讨高氧与临床结局关系的观察性和干预性研究及体外生命支持组织指南,整合为叙述性综述并附相关研究汇总。
  • ECMO回路对全身氧合的贡献在实践中主要由ECMO血流量决定,自身氧合贡献来自自身心输出量和残余呼吸功能。
  • ECMO输出与自身心输出量交互(如差异性低氧)、呼吸支持的存在及影响血氧运输的生理参数共同调节静脉-动脉ECMO期间的总体氧暴露。
  • 高氧定义多样,最常用为PaO2>150 mm Hg;严重高氧(原文写作PaO2>300 mm Hg)常见,见于20%。
  • 早期严重高氧及累积高氧暴露与院内死亡相关,在静脉-动脉ECMO和体外心肺复苏中校正疾病严重度后仍相关。
  • 实用方法:目标右桡动脉血氧饱和度94-98%,选择性患者通过空氧混合器调节吸入氧分数使氧合器后PaO2达150-300 mm Hg。

证据类型、等级与局限

  • 证据类型:叙述性综述,纳入观察性和干预性研究及体外生命支持组织指南。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对于外周静脉-动脉ECMO患者,可采用目标右桡动脉血氧饱和度94-98%的氧合策略。
  • 在选择性患者中,可通过空氧混合器调节吸入氧分数,目标氧合器后PaO2 150-300 mm Hg。
  • 该实用方法旨在避免高氧同时防止低氧。

指南或共识出处

  • 体外生命支持组织(Extracorporeal Life Support Organization)指南。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: This review aims to: 1) identify the key circuit and patient factors affecting systemic oxygenation, 2) summarize the literature reporting the association between hyperoxia and patient outcomes, and 3) provide a pragmatic approach to oxygen titration, in patients undergoing peripheral venoarterial extracorporeal membrane oxygenation (ECMO).

DATA SOURCES: Searches were performed using PubMed, SCOPUS, Medline, and Google Scholar.

STUDY SELECTION: All observational and interventional studies investigating the association between hyperoxia, and clinical outcomes were included, as well as guidelines from the Extracorporeal Life Support Organization.

DATA EXTRACTION: Data from relevant literature was extracted, summarized, and integrated into a concise narrative review. For ease of reference a summary of relevant studies was also produced.

DATA SYNTHESIS: The extracorporeal circuit and the native cardiorespiratory circuit both contribute to systemic oxygenation during venoarterial ECMO. The ECMO circuit's contribution to systemic oxygenation is, in practice, largely determined by the ECMO blood flow, whereas the native component of systemic oxygenation derives from native cardiac output and residual respiratory function. Interactions between ECMO outflow and native cardiac output (as in differential hypoxia), the presence of respiratory support, and physiologic parameters affecting blood oxygen carriage also modulate overall oxygen exposure during venoarterial ECMO. Physiologically those requiring venoarterial ECMO are prone to hyperoxia. Hyperoxia has a variety of definitions, most commonly Pa o2 greater than 150 mm Hg. Severe hypoxia (Pa o2 > 300 mm Hg) is common, seen in 20%. Early severe hyperoxia, as well as cumulative hyperoxia exposure was associated with in-hospital mortality, even after adjustment for disease severity in both venoarterial ECMO and extracorporeal cardiopulmonary resuscitation. A pragmatic approach to oxygenation during peripheral venoarterial ECMO involves targeting a right radial oxygen saturation target of 94-98%, and in selected patients, titration of the fraction of oxygen in the mixture via the air-oxygen blender to target postoxygenator Pa o2 of 150-300 mm Hg.

CONCLUSIONS: Hyperoxia results from a range of ECMO circuit and patient-related factors. It is common during peripheral venoarterial ECMO, and its presence is associated with poor outcome. A pragmatic approach that avoids hyperoxia, while also preventing hypoxia has been described for patients receiving peripheral venoarterial ECMO.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Premraj L, Brown A, Fraser JF, et al. Oxygenation During Venoarterial Extracorporeal Membrane Oxygenation: Physiology, Current Evidence, and a Pragmatic Approach to Oxygen Titration. Crit Care Med. 2023. PMID: 38059745. doi:10.1097/CCM.0000000000006134

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。