脓毒症休克中液体耐受性与液体复苏的聚焦心脏超声表现
这项回顾性观察性队列研究纳入2018至2021年美国一家大学附属三级医院急诊科就诊的脓毒症休克患者,评估聚焦心脏超声(FCU)发现的液体耐受(FT)是否与3小时内接受SEP-1推荐的30 mL/kg液体负荷相关。1,024例患者中292例在脓毒症发作3小时内接受FCU,177例判定为FT,115例为液体耐受不良(pFT)。FT患者达到30 mL/kg液体负荷的比例高于pFT患者(52.0% vs 31.3%,风险差20.7% [95%CI 9.4-31.9]),未接受FCU者达标率为34.3%;FT患者3小时内接受液体量更多(2,271 mL vs 1,646 mL,平均差625 mL [95%CI 330-919])。多因素logistic回归显示FT与达标几率更高相关(OR 2.17 [1.52-3.12]),但组间28天死亡率、血管活性药需求和机械通气需求无差异。
要点
- 脓毒症休克患者中,FCU判定为液体耐受者3小时内达到30 mL/kg液体负荷的比例为52.0%,高于液体耐受不良者的31.3%(风险差20.7% [95%CI 9.4-31.9])。
- 未接受FCU的患者30 mL/kg液体负荷达标率为34.3%。
- 液体耐受患者3小时内接受液体量为2,271 mL,液体耐受不良患者为1,646 mL,平均差625 mL(95%CI 330-919)。
- 多因素logistic回归校正患者特征和血流动力学不稳定标志后,液体耐受与达到液体负荷要求的几率更高相关(OR 2.17 [1.52-3.12])。
- 组间28天死亡率、血管活性药需求和机械通气需求无差异。
适用人群与场景
- 2018至2021年美国一家大学附属三级医院急诊科就诊的脓毒症休克患者。
研究设计与关键结果
- 回顾性观察性队列研究,纳入1,024例脓毒症休克患者,其中292例在脓毒症发作3小时内接受FCU,177例判定为液体耐受(FT),115例为液体耐受不良(pFT)。
- FT患者达到30 mL/kg液体负荷的比例为52.0%,pFT患者为31.3%,风险差20.7%(95%CI 9.4-31.9);未接受FCU者达标率为34.3%。
- FT患者3小时内接受液体量为2,271 mL,pFT患者为1,646 mL,平均差625 mL(95%CI 330-919)。
- 多因素logistic回归校正患者特征和血流动力学不稳定标志后,液体耐受与达到液体负荷要求的几率更高相关(OR 2.17 [1.52-3.12])。
- 组间28天死亡率、血管活性药需求和机械通气需求无差异。
证据类型、等级与局限
- 证据类型:回顾性观察性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,经FCU判定为液体耐受的脓毒症休克患者更可能接受SEP-1集束化推荐的30 mL/kg液体负荷;与液体耐受不良或未接受FCU的患者相比,液体耐受与达标几率更高相关(OR 2.17 [1.52-3.12])。
- 组间28天死亡率、血管活性药需求和机械通气需求无差异。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Compliance with the fluid bonus component of the SEP-1 (severe sepsis and septic shock management) bundle remains poor due to concerns for iatrogenic harm from fluid overload. We sought to assess whether patients who received focused cardiac ultrasound (FCU) and were found to be fluid tolerant (FT) were more likely to receive the recommended 30 mL/kg fluid bolus within 3 hours of sepsis identification.
DESIGN: Retrospective, observational cohort study.
SETTING: University-affiliated, tertiary-care hospital in the United States.
PATIENTS: Emergency department patients presenting with septic shock from 2018 to 2021. The primary exposure was receipt of FCU with identification of fluid tolerance 3 hours from onset of septic shock.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Two hundred ninety-two of 1,024 patients with septic shock received FCU within 3 hours of sepsis onset. One hundred seventy-seven were determined to be FT. One hundred fifteen patients were determined to have poor fluid tolerance (pFT). FT patients were more likely to reach the recommended 30 mL/kg fluid bolus amount compared with pFT (FT 52.0% vs. pFT 31.3%, risk difference: 20.7%, [95% CI, 9.4-31.9]). Patients who did not receive FCU met the bolus requirement 34.3% of the time. FT patients received more fluid within 3 hours (FT 2,271 mL vs. pFT 1,646 mL, mean difference 625 mL [95% CI, 330-919]). Multivariable logistic regression was used to estimate the association between fluid tolerance FCU findings and compliance with 30 mL/kg bolus after adjustment for patient characteristics and markers of hemodynamic instability. FT with associated with a higher likelihood of meeting bolus requirement (odds ratio 2.17 [1.52-3.12]).
CONCLUSIONS: Patients found to be FT by FCU were more likely to receive the recommended 30 mL/kg bolus in the SEP-1 bundle when compared with patients found with pFT or those that did not receive FCU. There was no difference between groups in 28-day mortality, vasopressor requirement, or need for mechanical ventilation.
参考来源
- Prevalska IG, Tucker RV, England PC, et al. Focused Cardiac Ultrasound Findings of Fluid Tolerance and Fluid Resuscitation in Septic Shock. Crit Care Explor. 2023. PMID: 38053747. doi:10.1097/CCE.0000000000001015
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。