重症监护病房拔管失败风险的性别差异
该研究为一项大规模临床试验的回顾性分析,纳入641例ICU高拔管失败风险患者,其中男性425例(66%)、女性216例(34%),旨在评估性别与拔管失败风险的关系。主要终点为拔管后7天内再插管。结果显示,男性48小时再插管率显著高于女性(11.0% vs 6.0%,差值+5.0%,95%CI 0.2-9.2,P=0.038),7天再插管率差异未达统计学显著(16.7% vs 11.1%,差值+5.6%,95%CI -0.3-10.8,P=0.059)。多因素logistic回归显示男性与7天内再插管独立相关(校正OR 1.70,95%CI 1.01-2.89,P=0.048)。作者认为未来重症患者研究应系统评估性别对结局的影响。
要点
- 在641例高拔管失败风险ICU患者中,男性48小时再插管率显著高于女性(11.0% vs 6.0%,差值+5.0%,95%CI 0.2-9.2,P=0.038)。
- 7天再插管率男性16.7% vs 女性11.1%(差值+5.6%,95%CI -0.3-10.8,P=0.059),差异未达统计学显著。
- 多因素logistic回归校正入院原因、体重指数、严重程度评分、拔管前呼吸频率及拔管后无创通气后,男性仍与7天内再插管独立相关(校正OR 1.70,95%CI 1.01-2.89,P=0.048)。
- 男性更多因心脏骤停入院且合并缺血性心脏病,女性更多因昏迷入院且合并肥胖。
适用人群与场景
- 一项大规模临床试验纳入的ICU高拔管失败风险患者,共641例,其中男性425例(66%),女性216例(34%)。
研究设计与关键结果
- 研究类型:一项大规模临床试验的事后分析,纳入641例ICU高拔管失败风险患者,男性425例(66%),女性216例(34%)。
- 主要终点:拔管后7天内再插管率,男性16.7% vs 女性11.1%,差值+5.6%(95%CI -0.3至10.8),P=0.059,未达统计学显著。
- 48小时再插管率:男性11.0% vs 女性6.0%,差值+5.0%(95%CI 0.2至9.2),P=0.038。
- 多因素logistic回归:校正入院原因、体重指数、严重程度评分、拔管前呼吸频率及拔管后无创通气后,男性与7天内再插管独立相关(校正OR 1.70,95%CI 1.01至2.89,P=0.048)。
- 基线特征:男性更多因心脏骤停入院且合并缺血性心脏病;女性更多因昏迷入院且合并肥胖。
证据类型、等级与局限
- 证据类型:一项大规模临床试验的事后分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,未来针对重症患者的研究应系统评估性别对结局的影响。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Little attention has been paid to potential differences in prognosis between mechanically ventilated males and females in intensive care units (ICUs). We hypothesized that a sex gap in the risk of extubation failure in ICUs may exist.
METHODS: Post hoc analysis of a large-scale clinical trial including patients at high risk of extubation failure in ICUs, with the aim of assessing the risk of extubation failure according to sex. The primary outcome was reintubation within the 7 days following extubation.
RESULTS: Out of 641 patients, 425 (66%) were males and 216 (34%) were females. Males were more likely to be admitted for cardiac arrest and to have underlying ischemic heart disease whereas females were more likely to be admitted for coma and to have obesity. Whereas the rate of reintubation at 48 h was significantly higher in males than in females (11.0% vs. 6.0%; difference, + 5.0 [95% CI, 0.2 to 9.2]; P = 0.038), the rate of reintubation at day 7 did not significantly differ between males and females (16.7% vs. 11.1%; difference, + 5.6% [95%CI, - 0.3 to 10.8], P = 0.059). Using multivariable logistic regression analysis, male sex was independently associated with reintubation within the 7 days following extubation (adjusted OR 1.70 [95% CI, 1.01 to 2.89]; P = 0.048), even after adjustment on reason for admission, body-mass index, severity score, respiratory rate before extubation, and noninvasive ventilation after extubation.
CONCLUSION: In this post hoc analysis of a clinical trial including a homogeneous subset of patients at high risk of extubation failure, sex was independently associated with reintubation. The role of sex on outcomes should be systematically examined in future studies of critically ill patients.
参考来源
- Thille AW, Boissier F, Coudroy R, et al. Sex difference in the risk of extubation failure in ICUs. Ann Intensive Care. 2023. PMID: 38112851. doi:10.1186/s13613-023-01225-7
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。