文献速递复苏、休克与脓毒症创伤与烧伤重症综合管理与镇静镇痛

大鼠严重损伤、失血性休克及全血复苏后骨骼肌异常灌注的超声造影参数成像评估

ASSESSMENT OF ABNORMAL SKELETAL MUSCLE PERFUSION BY CONTRAST-ENHANCED ULTRASOUND WITH PARAMETRIC IMAGING IN RATS AFTER SEVERE INJURY, HEMORRHAGIC SHOCK, AND WHOLE BLOOD RESUSCITATION.
PubMed 文献 · Shock · 2023-11-15
一句话结论大鼠多伤合并失血性休克全血复苏后血压正常,但未损伤骨骼肌微血管血流仍持续降低、血栓弹力强度与血小板计数持续低下,参数超声造影显示主要机制为微血管阻塞。

研究建立大鼠多伤合并压力目标性动脉导管失血及全血复苏模型,用参数超声造影测量未损伤股四头肌微血管血流,同时检测黏弹性血凝块强度和全血细胞计数。共16只雄性Sprague-Dawley大鼠分为假手术组与创伤组。复苏后血压恢复正常,但微血管血流降低并持续至实验结束,主要由血容量减少驱动、血流速度相对保留;血凝块强度和血小板计数也持续降低。结论认为该模型可用于深入研究创伤后微血管阻塞与创伤诱导性凝血病。

要点

  • 16只雄性Sprague-Dawley大鼠中,创伤组接受标准化多伤及压力目标性动脉导管失血后全血复苏。
  • 复苏后血压恢复正常,但未损伤股四头肌微血管血流降低并持续至实验结束。
  • 微血管血流降低主要由血容量减少驱动,血流速度相对保留。
  • 黏弹性血凝块强度与血小板计数降低并持续至实验结束。
  • 参数超声造影分析提示该变化主要归因于微血管阻塞。

适用人群与场景

  • 16只雄性Sprague-Dawley大鼠,麻醉、通气并置管。
  • 分为假手术组(无损伤)和创伤组(标准化多伤及压力目标性动脉导管失血后全血复苏)。
  • 测量对象为未损伤股四头肌。

处置流程与药物剂量

  • 创伤组行标准化多伤及压力目标性动脉导管失血,随后全血复苏。
  • 在预设时间点进行超声造影测量未损伤股四头肌微血管血流、黏弹性血凝块强度和全血细胞计数。

研究设计与关键结果

  • 复苏后血压恢复正常,但微血管血流降低并持续至实验结束。
  • 微血管血流降低主要由血容量减少驱动,血流速度相对保留。
  • 黏弹性血凝块强度和血小板计数降低并持续至实验结束。
  • 参数超声造影分析显示微血管血流变化主要归因于微血管阻塞。

证据类型、等级与局限

  • 动物实验(大鼠模型)。
  • 原文结论指出该平台可用于加深对这一重要过程的理解。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为该大鼠模型可用于进一步研究创伤后持续存在的微血管血流异常和创伤诱导性凝血病。
  • 参数超声造影可无创评估大而深的血管床微血管血流,作者认为在此场景下尤其有优势。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Background: After severe injury, optical measures of microvascular blood flow (MBF) decrease and do not normalize with resuscitation to normal blood pressure. These changes are associated with organ dysfunction, coagulopathy, and death. However, the pathophysiology is not well understood. Several possible pathways could also contribute to the development of trauma-induced coagulopathy (TIC). A small-animal model of trauma-related MBF derangement that persists after resuscitation and includes TIC would facilitate further study. Parametric contrast-enhanced ultrasound (CEUS) is particularly advantageous in this setting, because it noninvasively assesses MBF in large, deep vascular beds. We sought to develop such a model, measuring MBF with CEUS. Methods: Sixteen male Sprague-Dawley rats were anesthetized, ventilated, and cannulated. Rats were subjected to either no injury (sham group) or a standardized polytrauma and pressure-targeted arterial catheter hemorrhage with subsequent whole blood resuscitation (trauma group). At prespecified time points, CEUS measurements of uninjured quadriceps muscle, viscoelastic blood clot strength, and complete blood counts were taken. Results: After resuscitation, blood pressure normalized, but MBF decreased and remained low for the rest of the protocol. This was primarily driven by a decrease in blood volume with a relative sparing of blood velocity. Viscoelastic blood clot strength and platelet count also decreased and remained low throughout the protocol. Conclusion: We present a rat model of MBF derangement in uninjured skeletal muscle and coagulopathy after polytrauma that persists after resuscitation with whole blood to normal macrohemodynamics. Parametric CEUS analysis shows that this change is primarily due to microvascular obstruction. This platform can be used to develop a deeper understanding of this important process.

来源:Shock,查看原文。版权归原作者所有。

参考来源

  1. St John A, Wang X, Ringgold K, et al. ASSESSMENT OF ABNORMAL SKELETAL MUSCLE PERFUSION BY CONTRAST-ENHANCED ULTRASOUND WITH PARAMETRIC IMAGING IN RATS AFTER SEVERE INJURY, HEMORRHAGIC SHOCK, AND WHOLE BLOOD RESUSCITATION. Shock. 2023. PMID: 38010084. doi:10.1097/SHK.0000000000002267

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。