文献速递创伤与烧伤消化、代谢与肾脏急症

改善急诊科创伤团队启动患者的CT扫描仪效率

Improving CT scanner efficiency for trauma team activations in the emergency department.
PubMed 文献 · Am J Emerg Med · 2023-10-30
一句话结论在急诊创伤团队启动患者中,采用5分钟预警通知策略可节省CT扫描仪空闲时间中位数19分钟,作者认为支持实施该策略。

该质量改进项目在2022年11月于大型城市I级创伤中心急诊科前瞻性追踪46例创伤团队启动(TTA)患者,将既往在院前TTA呼叫时即清空CT扫描仪的做法,改为由团队负责人在患者稳定过程中提示急诊书记员向CT人员发出「5分钟预警」(5-min HU)通知后再清空扫描仪。结果显示,从5-min HU通知到CT到达的中位时间为5.0分钟(IQR 4.0分钟),新策略较旧策略每例患者节省CT扫描仪空闲时间中位数19分钟(p < 0.0001),共节省818分钟(13.6小时)。作者认为这些数据支持在急诊科对TTA患者实施5-min HU策略,以在TTA患者稳定期间最大化CT扫描仪对其他患者的可用性。

要点

  • 在46例TTA患者中,新5-min HU策略较旧策略每例节省CT扫描仪空闲时间中位数19分钟(p < 0.0001),共节省818分钟(13.6小时)。
  • 从5-min HU通知到CT到达的中位时间为5.0分钟(IQR 4.0分钟)。
  • 从初始TTA广播到CT到达的中位时间为24.0分钟(IQR 9.0分钟),旧策略下扫描仪会被占用整个时段。
  • 纳入的TTA中钝性创伤占85%(n=39),穿透性创伤占15%(n=7)。
  • 作者认为这些数据支持在急诊科对TTA患者实施5-min HU策略,以最大化CT扫描仪对其他急诊患者的可用性。

适用人群与场景

  • 2022年11月在大型城市I级创伤中心急诊科收治的创伤团队启动(TTA)患者,采用方便抽样,共46例;钝性创伤85%(n=39),穿透性创伤15%(n=7)。

诊断标准与关键阈值

  • TTA启动标准:患者遭受危及生命或肢体的损伤,需要大型救治团队资源。
  • 新策略触发条件:团队负责人在患者稳定过程中提示急诊书记员向CT人员发出「5分钟预警」(5-min HU)通知,此时清空CT扫描仪。

处置流程与药物剂量

  • 旧策略:在院前TTA呼叫时即清空CT扫描仪。
  • 新策略:团队负责人在患者稳定过程中提示急诊书记员向CT扫描仪人员发出5-min HU通知,此时清空CT扫描仪。
  • 研究收集的时间点包括:TTA通知页面、5-min HU通知、到达CT。

研究设计与关键结果

  • 研究类型:质量改进项目,前瞻性追踪46例TTA(方便抽样),于2022年11月在一家大型城市I级创伤中心急诊科进行;采用Mann-Whitney U非参数检验分析。
  • 从初始TTA广播到CT到达的中位时间为24.0分钟(IQR 9.0分钟);旧策略下扫描仪会被占用整个时段。
  • 从5-min HU通知到CT到达的中位时间为5.0分钟(IQR 4.0分钟)。
  • 新策略较旧策略每例患者节省CT扫描仪空闲时间中位数19分钟(p < 0.0001)。
  • 总共节省CT扫描仪时间818分钟(13.6小时)。

证据类型、等级与局限

  • 证据类型:质量改进项目(前瞻性追踪,方便抽样46例TTA)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为这些数据支持在急诊科对TTA患者实施5-min HU策略,以在TTA患者稳定期间最大化CT扫描仪对其他急诊患者的可用性。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND AND OBJECTIVES: A Trauma Team Activation (TTA) is initiated when a patient has sustained a life or limb-threatening injury thereby necessitating resources of a large care team. Previously, a CT scanner was cleared at the time of the prehospital TTA call. Wide variability in the time it took to stabilize patients often led to extended CT scanner idle time. A new policy was developed whereby the team leader would prompt the ED clerk to provide a '5-min heads-up' (5-min HU) notification to the CT scanner personnel as a patient was stabilized. At this point, the CT scanner was cleared. The purpose of this quality improvement project is to evaluate if the new policy saves CT scanner idle time.

METHODS: Research interns prospectively followed incoming TTAs in the ED of a large, urban, Level I Trauma Center in November 2022. The interns collected the following time points: TTA notification page, 5-min HU notification, and arrival to CT. Data was analyzed using a non-parametric comparison test (Mann-Whitney U).

RESULTS: A convenience sample of 46 TTAs was included. Trauma was blunt (85%; n = 39)) and penetrating (15%; n = 7). The median initial TTA announcement to CT arrival time was 24.0 min (IQR: 9.0 min). Previously, the scanner would have been held for this entire period. The median time from 5-min HU notification to CT arrival was 5.0 min (IQR: 4.0 min). The new policy saved a median of 19 min of CT scanner idle time per patient compared to the old policy (p < 0.0001). The total CT scanner time saved was 818 min (13.6 h).

CONCLUSION: These data support the implementation of a 5-min HU policy in the ED for patients arriving as TTAs. This maximizes the availability of CT scanners for other patients in the ED while TTA patients are being stabilized.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Zwank MD, McGonigal MD, Adams NR, et al. Improving CT scanner efficiency for trauma team activations in the emergency department. Am J Emerg Med. 2023. PMID: 37925757. doi:10.1016/j.ajem.2023.10.040

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。