文献速递心脑血管急症重症综合管理与镇静镇痛

改进经颅多普勒波形分析用于创伤性脑损伤患者颅内高压评估

Improved Transcranial Doppler Waveform Analysis for Intracranial Hypertension Assessment in Patients with Traumatic Brain Injury.
PubMed 文献 · Neurocrit Care · 2023-11-06
一句话结论在创伤性脑损伤患者中,搏动性表观阻力(PaR)对颅内高压(ICP>20 mm Hg)的鉴别能力(AUC 0.77)优于搏动指数(PI,AUC 0.63);排除神经外科手术患者后PaR的AUC达0.89。

本研究为前瞻性研究,纳入神经重症监护病房收治的、入院5天内需要有创ICP监测的创伤性脑损伤患者93例,在双侧大脑中动脉进行经颅多普勒测量并计算PI和PaR,比较两者对颅内高压(ICP≥20 mm Hg)的预测价值。结果显示,20例(22%)患者在记录期间出现颅内高压;PI的鉴别能力较低(AUC 0.63),PaR略高(AUC 0.77)。非参数分析显示,有颅内高压患者PaR中位数为0.169,无颅内高压患者为-0.052(p=0.001);PI中位数分别为0.86和0.77(p=0.041)。排除接受神经外科手术的患者后,PaR的AUC升至0.89,PI的AUC为0.72;在该亚组中,PaR截断值-0.023的敏感性为100%,特异性为52.9%。作者认为PaR似乎是检测颅内高压的可靠无创参数,但进一步研究对于明确其临床应用是必要的。

要点

  • 在93例需有创ICP监测的创伤性脑损伤患者中,20例(22%)出现颅内高压(ICP>20 mm Hg)。
  • PaR对颅内高压的鉴别能力(AUC 0.77)优于PI(AUC 0.63)。
  • 有颅内高压患者PaR中位数0.169,无颅内高压患者-0.052(p=0.001);PI中位数分别为0.86和0.77(p=0.041)。
  • 排除接受神经外科手术的患者后,PaR的AUC为0.89,PI的AUC为0.72;PaR截断值-0.023的敏感性100%、特异性52.9%。
  • 作者认为PaR似乎是检测颅内高压的可靠无创参数,但需进一步研究明确其临床应用。

适用人群与场景

  • 创伤性脑损伤患者,收治于神经重症监护病房,入院5天内需要行有创颅内压监测。

诊断标准与关键阈值

  • 颅内高压定义为ICP>20 mm Hg;亚组分析中采用ICP≥20 mm Hg评估鉴别能力。

研究设计与关键结果

  • 研究类型为前瞻性研究,共纳入93例创伤性脑损伤患者,20例(22%)在记录期间出现颅内高压。
  • PI对颅内高压的鉴别能力较低(AUC 0.63),PaR略高(AUC 0.77)。
  • 有颅内高压患者PaR中位数0.169,无颅内高压患者中位数-0.052(p=0.001);PI中位数分别为0.86和0.77(p=0.041)。
  • 排除接受神经外科手术的患者后,PaR的AUC为0.89,PI的AUC为0.72;在该亚组中,PaR截断值-0.023的敏感性为100%,特异性为52.9%。

证据类型、等级与局限

  • 证据类型:前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为PaR似乎是检测颅内高压的可靠无创参数,但需进一步研究明确其临床应用,尤其是在辅助神经外科决策、重症监护病房随访以及根据治疗反应进行评估方面。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Transcranial Doppler (TCD) is a noninvasive bedside tool for cerebral hemodynamic assessments in multiple clinical scenarios. TCD, by means of measuring systolic and diastolic blood velocities, allows the calculation of the pulsatility index (PI), a parameter that is correlated with intracranial pressure (ICP). Nevertheless, the predictive value of the PI for raised ICP appears to be low, as it is subjected to several, often confounding, factors not related to ICP. Recently, the pulsatile apparent resistance (PaR) index was developed as a PI corrected for arterial blood pressure, reducing some of the confounding factors influencing PI. This study compares the predictive value of PaR versus PI for intracranial hypertension (IH) (ICP > 20 mm Hg) in patients with traumatic brain injury.

METHODS: Patients with traumatic brain injury admitted to the neurocritical care unit who required invasive ICP monitoring were included prospectively within 5 days of admission. TCD measurements were performed in both middle cerebral arteries, allowing calculations of the PI and PaR. The optimal cutoff, discriminative power of these parameters for ICP ≥ 20 mm Hg, was assessed by calculating the area under the receiver operator characteristics curve (AUC).

RESULTS: In total, 93 patients were included. A total of 20 (22%) patients experienced IH during the recording sessions. The discriminative power was low for PI (AUC 0.63) but slightly higher for PaR (AUC 0.77). Nonparametric analysis indicated significant difference for PaR when comparing patients with (median 0.169) and without IH (median - 0.052, p = 0.001), whereas PI medians for patients with and without IH were 0.86 and 0.77, respectively (p = 0.041). Regarding subanalyses, the discriminative power of these parameters increased after exclusion of patients who had undergone a neurosurgical procedure. This was especially true for the PaR (AUC 0.89) and PI (AUC 0.72). Among these patients, a PaR cutoff value of - 0.023 had 100% sensitivity and 52.9% specificity.

CONCLUSIONS: In the present study, discriminative power of the PaR for discriminating IH was superior to the PI. The PaR seems to be a reliable noninvasive parameter for detecting IH. Further studies are warranted to define its clinical application, especially in aiding neurosurgical decision making, following up in intensive care units, and defining its ability to indicate responses according to the therapies administered.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Brasil S, Romeijn H, Haspels EK, et al. Improved Transcranial Doppler Waveform Analysis for Intracranial Hypertension Assessment in Patients with Traumatic Brain Injury. Neurocrit Care. 2023. PMID: 37932509. doi:10.1007/s12028-023-01849-4

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。