文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

可视化机械通气患者的动态机械功率与时间负荷:MIMIC-IV数据库分析

Visualizing the dynamic mechanical power and time burden of mechanical ventilation patients: an analysis of the MIMIC-IV database.
PubMed 文献 · J Intensive Care · 2023-11-29
一句话结论MIMIC-IV 6251例显示动态机械功率越高可耐受时间越短,累积高功率或长时间通气与死亡风险升高相关。

该研究基于MIMIC-IV数据库纳入6251例接受机械通气的危重患者,开发可视化方法计算所有通气时长与强度组合的生存比值比,评估二者与死亡风险的关系。彩色编码图显示较高动态机械功率仅能耐受较短时间;三条拟合等高线分别代表死亡风险增加0%、10%、20%,呈指数模式:动态机械功率越高,暴露时间越短即与死亡风险升高相关。结论认为累积暴露于较高强度和/或较长机械通气时间与更差结局相关,同时考虑强度与时长可能有助于评估患者结局并指导调整机械通气以减少有害暴露。

要点

  • 纳入MIMIC-IV数据库6251例接受机械通气的危重患者,分析动态机械功率与通气时长组合的生存比值比。
  • 彩色编码图显示较高动态机械功率仅能耐受较短时间,三条拟合等高线分别代表死亡风险增加0%、10%、20%。
  • 拟合等高线呈指数模式:动态机械功率越高,暴露时间越短即与死亡风险升高相关。
  • 累积暴露于较高强度和/或较长机械通气时间与更差结局相关。
  • 同时考虑机械通气强度与时长可能有助于评估患者结局并指导调整机械通气以减少有害暴露。

适用人群与场景

  • 从MIMIC-IV数据库识别的接受机械通气的危重患者,共6251例。

研究设计与关键结果

  • 研究类型为基于MIMIC-IV数据库的分析,纳入6251例接受机械通气的危重患者。
  • 开发可视化方法,计算所有通气时长与强度组合的生存比值比,以评估机械通气强度与时长和死亡风险的关系。
  • 彩色编码图显示较高动态机械功率仅能耐受较短时间。
  • 三条拟合等高线分别代表死亡风险增加0%、10%、20%,呈指数模式:动态机械功率越高,暴露时间越短即与死亡风险升高相关。

证据类型、等级与局限

  • 证据类型:基于MIMIC-IV数据库的分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 同时考虑机械通气强度与时长可能有助于评估患者结局并指导调整机械通气以减少有害暴露(作者认为)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Limiting driving pressure and mechanical power is associated with reduced mortality risk in both patients with and without acute respiratory distress syndrome. However, it is still poorly understood how the intensity of mechanical ventilation and its corresponding duration impact the risk of mortality.

METHODS: Critically ill patients who received mechanical ventilation were identified from the Medical Information Mart for Intensive Care (MIMIC)-IV database. A visualization method was developed by calculating the odds ratio of survival for all combinations of ventilation duration and intensity to assess the relationship between the intensity and duration of mechanical ventilation and the mortality risk.

RESULTS: A total of 6251 patients were included. The color-coded plot demonstrates the intuitive concept that episodes of higher dynamic mechanical power can only be tolerated for shorter durations. The three fitting contour lines represent 0%, 10%, and 20% increments in the mortality risk, respectively, and exhibit an exponential pattern: higher dynamic mechanical power is associated with an increased mortality risk with shorter exposure durations.

CONCLUSIONS: Cumulative exposure to higher intensities and/or longer duration of mechanical ventilation is associated with worse outcomes. Considering both the intensity and duration of mechanical ventilation may help evaluate patient outcomes and guide adjustments in mechanical ventilation to minimize harmful exposure.

来源:J Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Chen H, Chen ZZ, Gong SR, et al. Visualizing the dynamic mechanical power and time burden of mechanical ventilation patients: an analysis of the MIMIC-IV database. J Intensive Care. 2023. PMID: 38031184. doi:10.1186/s40560-023-00709-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。