文献速递心脑血管急症

急诊主动脉夹层超声评估方案(SPEED方案):一项多中心、前瞻性、观察性研究

The sonographic protocol for the emergent evaluation of aortic dissections (SPEED protocol): A multicenter, prospective, observational study.
PubMed 文献 · Acad Emerg Med · 2023-12-19
一句话结论SPEED方案(经胸超声心动图联合腹主动脉床旁超声)诊断主动脉夹层敏感性93.2%、阴性预测值99.7%,可在急诊科用于不稳定患者。

该多中心、前瞻性、观察性队列研究纳入疑似主动脉夹层的成人患者,行经胸超声心动图与腹主动脉床旁超声,以心包积液、内膜片或主动脉流出道直径>35 mm任一征象提示夹层。共完成1314例床旁超声检查,诊断21例Stanford A型与23例Stanford B型夹层,44例中41例至少存在上述一项超声征象。方案敏感性93.2%(95%CI 81.3-98.6)、特异性90.9(95%CI 89.2-92.5)、阳性预测值26.3%(95%CI 19.6-33.9)、阴性预测值99.7%(95%CI 99.2-100)、准确率91%(95%CI 89.3-92.5)。

要点

  • SPEED方案以心包积液、内膜片或主动脉流出道直径>35 mm任一征象阳性提示主动脉夹层。
  • 方案敏感性93.2%(95%CI 81.3-98.6),阴性预测值99.7%(95%CI 99.2-100),阴性时排除夹层的把握较高。
  • 阳性预测值仅26.3%(95%CI 19.6-33.9),阳性结果需进一步影像学确认。
  • 44例夹层中41例至少存在一项上述超声征象,3例无任何征象。
  • 研究纳入的是疑似主动脉夹层的成人患者,床旁超声在急诊科完成。

适用人群与场景

  • 机构审查委员会批准的多中心、前瞻性、观察性队列研究,纳入疑似主动脉夹层的成人患者(便利样本)。

诊断标准与关键阈值

  • 三项超声征象提示主动脉夹层:心包积液、内膜片、主动脉流出道直径>35 mm,任一存在即为阳性。

研究设计与关键结果

  • 共完成1314例床旁超声检查,诊断21例Stanford A型与23例Stanford B型主动脉夹层。
  • 44例夹层中41例至少存在一项上述超声征象。
  • 敏感性93.2%(95%CI 81.3-98.6),特异性90.9(95%CI 89.2-92.5)。
  • 阳性预测值26.3%(95%CI 19.6-33.9),阴性预测值99.7%(95%CI 99.2-100)。
  • 准确率91%(95%CI 89.3-92.5)。

证据类型、等级与局限

  • 证据类型:多中心、前瞻性、观察性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对疑似主动脉夹层且不宜离开急诊科行CT血管造影的患者,可床旁行经胸超声心动图联合腹主动脉超声评估(作者结论支持该方案总体敏感性93.2%)。
  • 方案阴性(无上述三项征象)时阴性预测值99.7%,但原文未据此给出排除夹层的推荐。
  • 阳性预测值26.3%,原文未据此给出阳性后处理推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: An aortic dissection (AoD) is a potentially life-threatening emergency with mortality rates exceeding 50%. While computed tomography angiography remains the diagnostic standard, patients may be too unstable to leave the emergency department. Investigators developed a point-of-care ultrasound (POCUS) protocol combining transthoracic echocardiography (TTE) and the abdominal aorta. The study objective was to determine the test characteristics of this protocol.

METHODS: This was an institutional review board-approved, multicenter, prospective, observational, cohort study of a convenience sample of adult patients. Patients suspected of having an AoD received a TTE and abdominal aorta POCUS. Three sonographic signs suggested AoD: a pericardial effusion, an intimal flap, or an aortic outflow track diameter measuring more than 35 mm. Investigators present continuous and categorical data as medians with interquartile ranges or proportions with 95% confidence intervals (CIs) and utilized standard 2 × 2 tables on MedCalc (Version 19.1.6) to calculate test characteristics with 95% CI.

RESULTS: Investigators performed 1314 POCUS examinations, diagnosing 21 Stanford type A and 23 Stanford type B AoD. Forty-one of the 44 cases had at least one of the aforementioned sonographic findings. The protocol has a sensitivity of 93.2% (95% CI 81.3-98.6), specificity of 90.9 (95% CI 89.2-92.5), positive and negative predictive values of 26.3% (95% CI 19.6-33.9) and 99.7% (95% CI 99.2-100), respectively, and an accuracy of 91% (95% CI 89.3-92.5).

CONCLUSIONS: The SPEED protocol has an overall sensitivity of 93.2% for AoD.

来源:Acad Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Gibbons RC, Smith D, Feig R, et al. The sonographic protocol for the emergent evaluation of aortic dissections (SPEED protocol): A multicenter, prospective, observational study. Acad Emerg Med. 2023. PMID: 38010071. doi:10.1111/acem.14839

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。