文献速递复苏、休克与脓毒症呼吸衰竭与机械通气重症综合管理与镇静镇痛

机器学习模型在危重症成人生物医学与信息系统信号中的应用

Application of Machine Learning Models to Biomedical and Information System Signals From Critically Ill Adults.
PubMed 文献 · Chest · 2023-11-01
一句话结论机器学习通知预测插管或升压药启动的准确性和精确性显著优于远程医疗系统警报和生物医学监护仪报警,警报负担分别低50倍和10倍。

本研究训练机器学习算法预测危重症成人的插管和升压药启动事件,并与生物医学监护仪报警及远程医疗系统警报进行比较。机器学习通知的准确性和精确性显著更高,预测升压药启动和插管事件时警报负担比远程医疗系统警报低50倍;远程医疗系统警报性能优于生物医学监护仪报警,警报负担低10倍。机器学习警报准确度为0.87-0.94,与其他临床可操作检测相当;远程医疗系统为0.28-0.53,生物医学监护仪为0.019-0.028。机器学习通知的F分数比远程医疗系统警报高五倍以上,远程医疗系统警报又高于生物医学监护仪报警。

要点

  • 机器学习通知预测升压药启动和插管的警报负担比远程医疗系统警报低50倍,准确性和精确性显著更高。
  • 机器学习警报准确度为0.87-0.94,远程医疗系统为0.28-0.53,生物医学监护仪为0.019-0.028。
  • 机器学习通知的F分数比远程医疗系统警报高五倍以上,远程医疗系统警报又高于生物医学监护仪报警。
  • 远程医疗系统警报性能显著优于生物医学监护仪报警,警报负担低10倍。
  • 机器学习通知在独立学术医学中心外部验证和COVID-19队列中表现相似。

适用人群与场景

  • 危重症成人,用于预测插管或升压药启动事件。

研究设计与关键结果

  • 研究训练机器学习算法预测危重症成人的插管和升压药启动事件,并与生物医学监护仪报警和远程医疗系统警报比较性能。
  • 机器学习通知预测升压药启动和插管事件时,准确性和精确性显著更高,警报负担比远程医疗系统警报低50倍。
  • 机器学习通知在内部验证队列、独立学术医学中心外部验证和COVID-19队列中表现相似。
  • 远程医疗系统检测特性显著优于生物医学监护仪报警,警报负担低10倍。
  • 机器学习警报准确度为0.87-0.94,远程医疗系统为0.28-0.53,生物医学监护仪为0.019-0.028。
  • 机器学习通知的F分数比远程医疗系统警报高五倍以上,远程医疗系统警报F分数高于生物医学监护仪报警。

证据类型、等级与局限

  • 证据类型:研究论文(机器学习模型开发与验证研究)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 机器学习衍生的通知可用于临床可操作的血液动力学不稳定和呼吸衰竭事件,因准确性、精确性、误分类率和事件前提前时间的差异幅度大,允许更主动的护理,并显著降低床边医生工作流程的频率和中断。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Machine learning (ML)-derived notifications for impending episodes of hemodynamic instability and respiratory failure events are interesting because they can alert physicians in time to intervene before these complications occur.

RESEARCH QUESTION: Do ML alerts, telemedicine system (TS)-generated alerts, or biomedical monitors (BMs) have superior performance for predicting episodes of intubation or administration of vasopressors?

STUDY DESIGN AND METHODS: An ML algorithm was trained to predict intubation and vasopressor initiation events among critically ill adults. Its performance was compared with BM alarms and TS alerts.

RESULTS: ML notifications were substantially more accurate and precise, with 50-fold lower alarm burden than TS alerts for predicting vasopressor initiation and intubation events. ML notifications of internal validation cohorts demonstrated similar performance for independent academic medical center external validation and COVID-19 cohorts. Characteristics were also measured for a control group of recent patients that validated event detection methods and compared TS alert and BM alarm performance. The TS test characteristics were substantially better, with 10-fold less alarm burden than BM alarms. The accuracy of ML alerts (0.87-0.94) was in the range of other clinically actionable tests; the accuracy of TS (0.28-0.53) and BM (0.019-0.028) alerts were not. Overall test performance (F scores) for ML notifications were more than fivefold higher than for TS alerts, which were higher than those of BM alarms.

INTERPRETATION: ML-derived notifications for clinically actioned hemodynamic instability and respiratory failure events represent an advance because the magnitude of the differences of accuracy, precision, misclassification rate, and pre-event lead time is large enough to allow more proactive care and has markedly lower frequency and interruption of bedside physician work flows.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Lilly CM, Kirk D, Pessach IM, et al. Application of Machine Learning Models to Biomedical and Information System Signals From Critically Ill Adults. Chest. 2023. PMID: 37923292. doi:10.1016/j.chest.2023.10.036

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。