文献速递复苏、休克与脓毒症儿科与产科急症

施救者利手对垂直单手胸外按压效果的影响比较

Comparisons of the vertical one-handed chest compressions according to the rescuer's handedness.
PubMed 文献 · Am J Emerg Med · 2023-11-10
一句话结论在儿科模拟人上,垂直单手胸外按压用优势手或非优势手,胸外按压深度无显著差异。

这项前瞻性随机交叉模拟试验纳入59名医生,在儿科模拟人上分别用优势手(试验1)和非优势手(试验2)进行2分钟单人垂直单手胸外按压。结果显示平均按压深度和达标深度比例在两组间无显著差异(平均深度52 mm vs 52 mm,P=0.625;达标深度97% vs 92%,P=0.619);优势手产生的平均按压力更大(23.1 kg vs 21.7 kg,P<0.001)。结论认为,尽管优势手按压力更大,但施救者利手不影响垂直单手胸外按压的按压深度。

要点

  • 在儿科模拟人上,优势手与非优势手垂直单手胸外按压的平均深度均为52 mm(IQR 49-57),P=0.625。
  • 达标按压深度比例优势手为97%(IQR 37-100),非优势手为92%(IQR 51-99),P=0.619。
  • 优势手平均按压力为23.1 kg ± 4.9,显著大于非优势手的21.7 kg ± 4.1,P<0.001。
  • 其他心肺复苏参数在优势手与非优势手之间无显著差异。
  • 施救者利手不影响垂直单手胸外按压的按压深度。

适用人群与场景

  • 59名医生在儿科模拟人上实施单人垂直单手胸外按压。

处置流程与药物剂量

  • 每名医生分别用优势手(试验1)和非优势手(试验2)进行2分钟单人垂直单手胸外按压心肺复苏。

研究设计与关键结果

  • 前瞻性随机交叉模拟试验纳入59名医生,在儿科模拟人上比较优势手与非优势手垂直单手胸外按压。
  • 平均按压深度:优势手52 mm(IQR 49-57) vs 非优势手52 mm(IQR 49-57),P=0.625。
  • 达标按压深度比例:优势手97%(IQR 37-100) vs 非优势手92%(IQR 51-99),P=0.619。
  • 平均按压力:优势手23.1 kg ± 4.9 vs 非优势手21.7 kg ± 4.1,优势手显著更大,P<0.001。
  • 其他心肺复苏参数在优势手与非优势手之间无显著差异。

证据类型、等级与局限

  • 证据类型:前瞻性随机交叉模拟试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在儿科模拟人上,施救者使用优势手或非优势手进行垂直单手胸外按压时,按压深度无显著差异;优势手产生的按压力更大,但这一差异未转化为按压深度的差异。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: The vertical one-handed chest compression (OHCC) technique has demonstrated superior compression power and chest compression depth (CCD) compared to conventional OHCC. This study aimed to determine if a rescuer's handedness influences the CCD during the vertical OHCC.

METHODS: This prospective randomized crossover simulation trial included 59 medical doctors. Each performed a 2-min single-rescuer cardiopulmonary resuscitation (CPR) on a pediatric manikin using the vertical OHCC, once with the dominant hand (Test 1) and once with the non-dominant hand (Test 2). CPR parameters were recorded in real-time via sensors in the manikin, and the compression force exerted by each hand was measured using a force plate.

RESULTS: The mean and adequate CCD did not differ significantly between Test 1 and 2 (mean depth: 52 mm (interquartile range [IQR]: 49-57) in Test 1 vs. 52 mm (IQR: 49-57) in Test 2, P = 0.625; adequate depth: 97% (IQR: 37-100) in Test 1 vs. 92% (IQR: 51-99) in Test 2, P = 0.619). The mean compression force was significantly greater in the dominant hand compared to the non-dominant hand (23.1 kg ± 4.9 in dominant hand vs. 21.7 kg ± 4.1 in non-dominant hand, P < 0.001). Other parameters showed no significant differences between Tests 1 and 2.

CONCLUSIONS: While vertical OHCC with a dominant hand generated greater force, the rescuer's handedness did not affect the CCD during the vertical OHCC.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Kim J, Oh JH, Min K, et al. Comparisons of the vertical one-handed chest compressions according to the rescuer's handedness. Am J Emerg Med. 2023. PMID: 37972504. doi:10.1016/j.ajem.2023.11.009

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。