重症患者心输出量可通过脉冲波多普勒分钟距离简便准确估算
该前瞻性观察研究在30张床位的ICU开展,纳入98例需要心输出量监测的成人患者,共167次心输出量测量。以脉冲波多普勒心输出量(PWD-CO)为参照,评估其与分钟距离(MD)及由MD推算的心输出量(MD-CO)的相关性和一致性。结果显示PWD-CO与MD-CO在总体人群中显著相关(R²=0.7,P<0.05),左心室射血分数低于60%时相关更佳(R²=0.85,P<0.05);Bland-Altman分析显示总体人群中位偏差0.02 L/min,一致性界限-1.92至+1.92 L/min,LVEF低于60%者中位偏差0.005 L/min,一致性界限-1.56至1.55 L/min,两者百分比误差均为17%。作者认为测量MD可简便、准确地估算重症患者的心输出量,尤其适用于左心室射血分数降低或保留的患者,有助于对循环衰竭患者更早进行心血管评估。
要点
- 在98例重症患者共167次测量中,PWD-CO与MD-CO总体显著相关(R²=0.7,P<0.05)。
- 左心室射血分数低于60%时相关性更佳(R²=0.85,P<0.05)。
- 总体人群中位偏差0.02 L/min,一致性界限-1.92至+1.92 L/min,百分比误差17%。
- LVEF低于60%者中位偏差0.005 L/min,一致性界限-1.56至1.55 L/min,百分比误差17%。
- 作者认为测量MD可简便、准确地估算心输出量,尤其适用于左心室射血分数降低或保留的患者。
适用人群与场景
- 在30张床位的ICU中,需要心输出量监测的成人重症患者。
- 纳入98例患者,其中男性67例(68%),中位年龄66岁(IQR 53-75岁),中位APACHE II评分22分(IQR 16-26)。
- 以休克为最常见入院原因者81例(82.7%),机械通气69例(70.4%),需要血管活性药物68例(70%)。
处置流程与药物剂量
- PWD-CO计算采用三次左心室流出道直径(LVOTd)和左心室流出道速度时间积分(LVOT-VTI)测量的平均值以及心率。
- 分钟距离(MD)由LVOT-VTI乘以心率获得。
- 通过线性回归方程由MD量化心输出量(MD-CO),并用Bland-Altman分析评估MD-CO与PWD-CO的一致性。
- 临床超声心动图数据在ICU入住后第一个24小时内收集,并在第一周内至少再收集一次。
研究设计与关键结果
- 研究类型为前瞻性观察研究,为期2年,在30张床位的ICU进行,纳入98例患者,共167次心输出量测量。
- 中位心输出量5.5 L/min(IQR 4.8-6.6 L/min),中位MD 1,850 cm/min(IQR 1,520-2,160 cm/min)。
- PWD-CO与MD-CO在总体人群中显著相关(R²=0.7,P<0.05);左心室射血分数低于60%时相关性提高(R²=0.85,P<0.05)。
- Bland-Altman分析显示总体人群中位偏差0.02 L/min,一致性界限-1.92至+1.92 L/min;LVEF低于60%者中位偏差0.005 L/min,一致性界限-1.56至1.55 L/min。
- 两种情况下百分比误差均为17%。
证据类型、等级与局限
- 证据类型:前瞻性观察研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在重症患者中测量MD可简便、准确地估算心输出量,尤其适用于左心室射血分数降低或保留的患者。
- 作者认为,这有助于对循环衰竭患者更早进行心血管评估,在临床或技术条件困难时尤其有意义。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Background: Cardiac output (CO) assessment is essential for management of patients with circulatory failure. Among the different techniques used for their assessment, pulsed-wave Doppler cardiac output (PWD-CO) has proven to be an accurate and useful tool. Despite this, assessment of PWD-CO could have some technical difficulties, especially in the measurement of left ventricular outflow tract diameter (LVOTd). The use of a parameter such as minute distance (MD) which avoids LVOTd in the PWD-CO formula could be a simple and useful way to assess the CO in critically ill patients. Therefore, the aim of this study was to evaluate the correlation and agreement between PWD-CO and MD. Methods: A prospective and observational study was conducted over 2 years in a 30-bed intensive care unit (ICU). Adult patients who required CO monitoring were included. Clinical echocardiographic data were collected within the first 24 h and at least once more during the first week of ICU stay. PWD-CO was calculated using the average value of three LVOTd and left ventricular outflow tract velocity-time integral (LVOT-VTI) measurements, and heart rate. Minute distance was obtained from the product of LVOT-VTI × heart rate. Pulsed-wave Doppler cardiac output was correlated with MD using linear regression. Cardiac output was quantified from the MD using the equation defined by linear regression. Bland-Altman analysis was also used to evaluate the level of agreement between CO calculated from MD (MD-CO) and PWD-CO. The percentage error was calculated. Results: A total of 98 patients and 167 CO measurements were analyzed. Sixty-seven (68%) were male, the median age was 66 years (interquartile range [IQR], 53-75 years), and the median Acute Physiology and Chronic Health Evaluation II score was 22 (IQR, 16-26). The most common cause of admission was shock in 81 patients (82.7%). Sixty-nine patients (70.4%) were mechanically ventilated, and 68 (70%) required vasoactive drugs. The median CO was 5.5 L/min (IQR, 4.8-6.6 L/min), and the median MD was 1,850 cm/min (IQR, 1,520-2,160 cm/min). There was a significant correlation between PWD-CO and MD-CO in the general population ( R2 = 0.7; P < 0.05). This correlation improved when left ventricular ejection fraction (LVEF) was less than 60% ( R2 = 0.85, P < 0.05). Bland-Altman analysis showed good agreement between PWD-CO and MD-CO in the general population, the median bias was 0.02 L/min, the limits of agreement were -1.92 to +1.92 L/min. The agreement was better in patients with LVEF less than 60% with a median bias of 0.005 L/min and limits of agreement of -1.56 to 1.55 L/min. The percentage error was 17% in both cases. Conclusion: Measurement of MD in critically ill patients provides a simple and accurate estimate of CO, especially in patients with reduced or preserved LVEF. This would allow earlier cardiovascular assessment in patients with circulatory failure, which is of particular interest in difficult clinical or technical conditions.