北美与英国ICU中低潮气量通气实施不佳:基于电子健康记录的分析
本研究利用英国CCHIC和美国eICU-CRD两个多中心电子健康记录ICU数据库,回顾性分析机械通气>48小时患者的低潮气量通气(LTVV,<8 mL/kg PBW)依从性及其与预后的关系。共纳入CCHIC 5,466例和eICU-CRD 7,384例患者,中位潮气量分别为7.48和7.91 mL/kg PBW。身高<160 cm(CCHIC)和<165 cm(eICU-CRD)、BMI>30 kg/m2及女性与中位潮气量>8 mL/kg PBW风险增加相关。中位潮气量<8 mL/kg PBW与CCHIC数据库30天死亡率降低相关(cause-specific HR 0.86, 95%CI 0.76-0.97),eICU-CRD中HR 0.9(95%CI 0.86-1.00)。CCHIC数据库中潮气量随时间显著下降。
要点
- 在CCHIC和eICU-CRD中,机械通气>48小时患者的中位潮气量分别为7.48和7.91 mL/kg PBW,LTVV实施有限。
- BMI>30 kg/m2与中位潮气量>8 mL/kg PBW风险增加相关(CCHIC OR 1.9, 95%CI 1.7-2.13;eICU-CRD OR 1.61, 95%CI 1.49-1.75)。
- 女性与中位潮气量>8 mL/kg PBW风险增加相关(CCHIC OR 2.39, 95%CI 2.16-2.65;eICU-CRD OR 2.29, 95%CI 2.26-2.31)。
- 中位潮气量<8 mL/kg PBW与CCHIC数据库30天死亡率降低相关(cause-specific HR 0.86, 95%CI 0.76-0.97),eICU-CRD中HR 0.9(95%CI 0.86-1.00)。
- CCHIC数据库中潮气量随时间显著下降。
适用人群与场景
- 英国CCHIC和美国eICU-CRD两个多中心电子健康记录ICU数据库中机械通气>48小时的患者。
研究设计与关键结果
- 研究类型:回顾性、多中心研究,纳入英国和美国机械通气>48小时患者;CCHIC 5,466例,eICU-CRD 7,384例。
- 中位潮气量:CCHIC 7.48 mL/kg PBW,eICU-CRD 7.91 mL/kg PBW。
- 中位潮气量>8 mL/kg PBW风险增加的相关因素:身高<160 cm(CCHIC)和<165 cm(eICU-CRD);BMI>30 kg/m2(CCHIC OR 1.9, 95%CI 1.7-2.13;eICU-CRD OR 1.61, 95%CI 1.49-1.75);女性(CCHIC OR 2.39, 95%CI 2.16-2.65;eICU-CRD OR 2.29, 95%CI 2.26-2.31)。
- 中位潮气量<8 mL/kg PBW与30天死亡率:CCHIC cause-specific HR 0.86(95%CI 0.76-0.97);eICU-CRD cause-specific HR 0.9(95%CI 0.86-1.00)。
- CCHIC数据库中潮气量随时间显著下降。
证据类型、等级与局限
- 证据类型:回顾性、多中心研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,英国和美国常规临床实践中LTVV实施有限;潮气量>8 mL/kg PBW与更差预后相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Low tidal volume ventilation (LTVV; < 8 mL/kg predicted body weight [PBW]) is a well-established standard of care associated with improved outcomes. This study used data collated in multicenter electronic health record ICU databases from the United Kingdom and the United States to analyze the use of LTVV in routine clinical practice.
RESEARCH QUESTION: What factors are associated with adherence to LTVV in the United Kingdom and North America?
STUDY DESIGN: This was a retrospective, multicenter study across the United Kingdom and United States of patients who were mechanically ventilated.
METHODS: Factors associated with adherence to LTVV were assessed in all patients in both databases who were mechanically ventilated for > 48 h. We observed trends over time and investigated whether LTVV was associated with patient outcomes (30-day mortality and duration of ventilation) and identified strategies to improve adherence to LTVV.
RESULTS: A total of 5,466 (Critical Care Health Informatics Collaborative [CCHIC]) and 7,384 electronic ICU collaborative research database [eICU-CRD] patients were ventilated for > 48 h and had data of suitable quality for analysis. The median tidal volume (VT) values were 7.48 mL/kg PBW (CCHIC) and 7.91 mL/kg PBW (eICU-CRD). The patients at highest risk of not receiving LTVV were shorter than 160 cm (CCHIC) and 165 cm (eICU-CRD). Those with BMI > 30 kg/m2 (CCHIC OR, 1.9 [95% CI, 1.7-2.13]; eICU-CRD OR, 1.61 [95% CI, 1.49-1.75]) and female patients (CCHIC OR, 2.39 [95% CI, 2.16-2.65]; eICU-CRD OR, 2.29 [95% CI, 2.26-2.31]) were at increased risk of having median VT > 8 mL/kg PBW. Patients with median VT < 8 mL/kg PBW had decreased 30-day mortality in the CCHIC database (CCHIC cause-specific hazard ratio, 0.86 [95% CI, 0.76-0.97]; eICU-CRD cause-specific hazard ratio, 0.9 [95% CI, 0.86-1.00]). There was a significant reduction in VT over time in the CCHIC database.
INTERPRETATION: There has been limited implementation of LTVV in routine clinical practice in the United Kingdom and the United States. VT > 8 mL/kg PBW was associated with worse patient outcomes.
参考来源
- Samanta RJ, Ercole A, Harris S, et al. Low Tidal Volume Ventilation Is Poorly Implemented for Patients in North American and United Kingdom ICUs Using Electronic Health Records. Chest. 2023. PMID: 37775039. doi:10.1016/j.chest.2023.09.021
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。