文献速递重症综合管理与镇静镇痛消化、代谢与肾脏急症

低剂量甲氧氟烷与一氧化二氮镇痛的环境影响:绿色哨子有多绿?

Environmental impact of low-dose methoxyflurane versus nitrous oxide for analgesia: how green is the 'green whistle'?
PubMed 文献 · Emerg Med J · 2024-01-22
一句话结论生命周期影响评估显示,Penthrox装置的全生命周期气候变化影响为0.84 kg CO2e,比Entonox低117.7倍,而等效剂量静脉吗啡仅为0.01 kg CO2e。

该研究采用生命周期影响评估(LCIA)方法,基于制造商数据、在线来源和Ecoinvent清单,在OpenLCA中分析Penthrox(甲氧氟烷)制造与使用全过程的碳排放,并与一氧化二氮及硫酸吗啡现有数据比较。结果显示Penthrox气候变化影响为0.84 kg CO2e,原料和生产过程贡献主要影响,原料占34.40%;Penthrox较Entonox低117.7倍CO2e。100 mg/100 mL硫酸吗啡静脉给药7 mg的气候变化影响为0.01 kg CO2e。作者认为在某些临床情境下以吸入甲氧氟烷替代一氧化二氮可能有助于NHS实现减排目标。

要点

  • Penthrox的全生命周期气候变化影响为0.84 kg CO2e,原料占34.40%。
  • Penthrox的气候变化影响比Entonox低117.7倍CO2e。
  • 等效剂量静脉硫酸吗啡(100 mg/100 mL中7 mg)的气候变化影响为0.01 kg CO2e,更低。
  • 作者认为在某些临床情境下以吸入甲氧氟烷替代一氧化二氮可能有助于NHS实现2032年减排80%的目标。

研究设计与关键结果

  • 研究类型:生命周期影响评估(LCIA),使用制造商数据、在线来源和LCIA清单Ecoinvent,在OpenLCA中分析。
  • 评估对象:Penthrox(甲氧氟烷)制造与使用全过程,并与一氧化二氮和硫酸吗啡现有数据比较。
  • 主要结果:Penthrox气候变化影响为0.84 kg CO2e;原料和生产过程贡献主要影响,原料占34.40%。
  • 对比结果:Penthrox较Entonox气候变化影响低117.7倍CO2e。
  • 对比结果:100 mg/100 mL硫酸吗啡静脉给药7 mg的气候变化影响为0.01 kg CO2e。

证据类型、等级与局限

  • 证据类型:生命周期影响评估(LCIA)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在某些临床情境下以吸入甲氧氟烷替代一氧化二氮可能有助于NHS实现2032年减排80%的目标。
  • 作者认为,Penthrox装置的全生命周期环境影响在气候变化方面优于一氧化二氮。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「适用人群与场景」「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The NHS has the target of reducing its carbon emission by 80% by 2032. Part of its strategy is using pharmaceuticals with a less harmful impact on the environment. Nitrous oxide is currently used widely within the NHS. Nitrous oxide, if released into the atmosphere, has a significant environmental impact. Methoxyflurane, delivered through the Penthrox 'green whistle' device, is a short-acting analgesic and is thought to have a smaller environmental impact compared with nitrous oxide.

METHODS: Life cycle impact assessment (LCIA) of all products and processes involved in the manufacture and use of Penthrox, using data from the manufacturer, online sources and LCIA inventory Ecoinvent. These data were analysed in OpenLCA. Impact data were compared with existing data on nitrous oxide and morphine sulfate.

RESULTS: This LCIA found that Penthrox has a climate change effect of 0.84 kg carbon dioxide equivalent (CO2e). Raw materials and the production process contributed to majority of the impact of Penthrox across all categories with raw materials accounting for 34.40% of the total climate change impact. Penthrox has a climate change impact of 117.7 times less CO2e compared with Entonox. 7 mg of 100 mg/100 mL of intravenous morphine sulfate had a climate change effect of 0.01 kg CO2e.

CONCLUSIONS: This LCIA has shown that the overall 'cradle-to-grave' environmental impact of Penthrox device is better than nitrous oxide when looking specifically at climate change impact. The climate change impact for an equivalent dose of intravenous morphine was even lower. Switching to the use of inhaled methoxyflurane instead of using nitrous oxide in certain clinical situations could help the NHS to reach its carbon emission reduction target.

来源:Emerg Med J,查看原文。版权归原作者所有。