文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

急诊插管关键操作错误分类体系

A taxonomy of key performance errors for emergency intubation.
PubMed 文献 · Am J Emerg Med · 2023-08-23
一句话结论对100次急诊插管的视频回顾性分析建立了13项喉镜操作错误分类,其中最常见的是会厌谷处镜片尖端提力不足(45%),最少见的是探条置入时过早移除喉镜(9%)。

该研究为前瞻性观察研究,回顾性编码了100次急诊科插管的去标识化喉镜录像,这些录像在研究前已被定性标记为显示次优技术。研究者预设了13项操作错误,分为三类:喉镜置入时的结构识别错误、会厌谷操作错误和器械递送错误。主要结局为各预设错误的发生率。结果显示最常见错误为镜片尖端位于会厌谷时提力不足致声门开放百分比降低(45%),最少见为探条置入时过早移除喉镜(9%)。作者认为需进一步研究如何将该分类纳入急诊气道培训和气道回顾流程。

要点

  • 13项操作错误分为三类:喉镜置入时结构识别错误、会厌谷操作错误和器械递送错误。
  • 最常见的错误是镜片尖端位于会厌谷时提力不足,发生率为45%。
  • 最不常见的错误是探条置入时过早移除喉镜,发生率为9%。
  • 研究纳入100次急诊插管尝试,来自研究前被定性标记为次优技术的便利样本。
  • 作者认为需进一步研究如何将该错误分类纳入急诊气道培训和气道回顾流程。

适用人群与场景

  • 急诊科行气管插管、且喉镜录像在研究前被定性标记为显示次优技术的患者(便利样本)。

研究设计与关键结果

  • 研究类型:前瞻性观察研究;样本量:100次插管尝试;人群:急诊科插管,录像在研究前被定性标记为次优技术。
  • 干预/方法:对去标识化喉镜录像进行编码,检测13项预设操作错误,分为结构识别错误(喉镜置入时)、会厌谷操作错误和器械递送错误三类。
  • 主要终点:各预设错误的发生率。最常见的错误是镜片尖端位于会厌谷时提力不足,降低声门开放百分比,发生率为45%;最不常见的错误是探条置入时过早移除喉镜,发生率为9%。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究;纳入的录像为研究前被定性标记为次优技术的便利样本。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,需进一步研究以确定如何最佳地将这13项操作错误分类纳入急诊气道培训与气道回顾流程。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

STUDY OBJECTIVE: Currently the videographic review of emergency intubations is an unstructured, qualitative process. We created a taxonomy of errors that impede the optimal procedural performance of emergency intubation.

METHODS: This was a prospective, observational, study reviewing a convenience sample of deidentified laryngoscopy recordings of emergency department intubations that were qualitatively flagged before the study as demonstrating suboptimal technique. These videos were coded for the presence of 13 predetermined performance errors. Our primary outcome was the incidence of each of these specified errors during emergency intubation. Errors fell into 3 categories: errors of structure recognition during laryngoscope insertion, errors of vallecula manipulation, and errors of device delivery.

RESULTS: A total of 100 intubation attempts were reviewed. The most common error was inadequate lifting force with the blade tip in the vallecula which lowered the percent of glottic opening, occurring in 45% of the attempts. The least common performance error was the premature removal of the laryngoscope during bougie placement, occurring in only 9% of the videos.

CONCLUSION: We developed a taxonomy of 13 performance errors of laryngoscopy. Further study is warranted to determine how to best incorporate these into emergency airway training and the airway review process.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Weingart SD, Barnicle RN, Janke A, et al. A taxonomy of key performance errors for emergency intubation. Am J Emerg Med. 2023. PMID: 37657143. doi:10.1016/j.ajem.2023.08.035