文献速递创伤与烧伤心脑血管急症呼吸衰竭与机械通气

重型创伤性脑损伤的院前气管插管:通气目标与死亡率——308例回顾性分析

Pre-hospital endotracheal intubation in severe traumatic brain injury: ventilation targets and mortality-a retrospective analysis of 308 patients.
PubMed 文献 · Scand J Trauma Resusc Emerg Med · 2023-09-12
一句话结论重型TBI院前插管患者入院时仅33%达到正常碳酸血症,入院PaCO2与死亡率强相关,PetCO2与PaCO2相关性差。

该回顾性队列研究纳入2014年1月至2019年12月由瑞士空中救援(Rega)从现场转运至瑞士两家一级创伤中心的、需现场气管插管的TBI患者,最终分析308例。评估收缩压、呼气末二氧化碳分压(PetCO2)、入院动脉血二氧化碳分压(PaCO2)及院前与现场时间对死亡率的影响。血压推荐依从率89%,按PetCO2判断45%为正常通气,仅29%同时满足SBP≥90 mm Hg且正常通气;因PetCO2与PaCO2相关性差,入院时仅33%为正常碳酸血症。入院正常碳酸血症与死亡概率降低强相关,院前及现场时间对死亡率无影响。作者认为对需现场插管的重型TBI患者,置入动脉导管及院前血气分析所需时间可能是值得的。

要点

  • 入院时仅33%患者达到正常碳酸血症,按PetCO2判断有45%为正常通气,PetCO2与PaCO2相关性差。
  • 入院正常碳酸血症与死亡概率降低强相关(多因素回归及logistic广义可加模型分析)。
  • 血压推荐依从率为89%,29%患者同时满足SBP≥90 mm Hg且按PetCO2判断为正常通气。
  • 院前时间与现场时间对死亡率无影响。
  • 作者认为对需现场插管的重型TBI患者,置入动脉导管及院前血气分析所需时间可能是值得的。

适用人群与场景

  • 2014年1月至2019年12月由瑞士空中救援(Rega)从现场转运至瑞士两家一级创伤中心的、需现场气管插管的TBI患者,最终分析308例。

研究设计与关键结果

  • 研究类型为回顾性队列研究,排除后557例中308例纳入分析。
  • 血压推荐依从率为89%;按PetCO2判断45%为正常通气,29%患者SBP≥90 mm Hg且按PetCO2判断为正常通气。
  • 因PetCO2与PaCO2相关性差,入院时仅33%为正常碳酸血症。
  • 入院正常碳酸血症与死亡概率降低强相关(多因素回归分析及logistic广义可加模型)。
  • 院前时间与现场时间对死亡率无影响。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,对需现场气管插管的重型TBI患者,置入动脉导管及院前血气分析所需时间可能是值得的。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Traumatic brain injury (TBI) remains one of the main causes of mortality and long-term disability worldwide. Maintaining physiology of brain tissue to the greatest extent possible through optimal management of blood pressure, airway, ventilation, and oxygenation, improves patient outcome. We studied the quality of prehospital care in severe TBI patients by analyzing adherence to recommended target ranges for ventilation and blood pressure, prehospital time expenditure, and their effect on mortality, as well as quality of prehospital ventilation assessed by arterial partial pressure of CO2 (PaCO2) at hospital admission.

METHODS: This is a retrospective cohort study of all TBI patients requiring tracheal intubation on scene who were transported to one of two major level 1 trauma centers in Switzerland between January 2014 and December 2019 by Swiss Air Rescue (Rega). We assessed systolic blood pressure (SBP), end-tidal partial pressure of CO2 (PetCO2), and PaCO2 at hospital admission as well as prehospital and on-scene time. Quality markers of prehospital care (PetCO2, SBP, prehospital times) and prehospital ventilation (PaCO2) are presented as descriptive analysis. Effect on mortality was calculated by multivariable regression analysis and a logistic general additive model.

RESULTS: Of 557 patients after exclusions, 308 were analyzed. Adherence to blood pressure recommendations was 89%. According to PetCO2, 45% were normoventilated, and 29% had a SBP ≥ 90 mm Hg and were normoventilated. Due to the poor correlation between PaCO2 and PetCO2, only 33% were normocapnic at hospital admission. Normocapnia at hospital admission was strongly associated with reduced probability of mortality. Prehospital and on-scene times had no impact on mortality.

CONCLUSIONS: PaCO2 at hospital admission is strongly associated with mortality risk, but normocapnia is achieved only in a minority of patients. Therefore, the time required for placement of an arterial cannula and prehospital blood gas analysis may be warranted in severe TBI patients requiring on-scene tracheal intubation.

来源:Scand J Trauma Resusc Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Knapp J, Doppmann P, Huber M, et al. Pre-hospital endotracheal intubation in severe traumatic brain injury: ventilation targets and mortality-a retrospective analysis of 308 patients. Scand J Trauma Resusc Emerg Med. 2023. PMID: 37700380. doi:10.1186/s13049-023-01115-8

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。