机械功率仅当按充气肺容积标准化时才与应力、应变和萎陷伤相关
该前瞻性队列研究纳入18例ARDS患者,调整通气设置使呼吸系统机械功率(MPRS)相近(23.75 J/min)。结果显示,尽管MPRS和跨肺机械功率(MPTp)相近,SLMP随PaO2/FiO2下降而线性升高(R=-0.83,p=0.0001)。仅当MPRS按充气肺容积标准化后,SLMP才与应力(R=0.9,p=0.00004)、应变(R=0.97,p<0.00001)和萎陷伤(R=0.82,p=0.00002)正相关;SMP也与上述指标相关。提示床旁可用SLMP或SMP评估VILI风险。
要点
- 18例ARDS患者调整通气使MPRS相近(23.75 J/min)后,SLMP随PaO2/FiO2下降而线性升高(R=-0.83,p=0.0001)。
- SLMP与应力相关(R=0.9,R2=0.84,p=0.00004),与应变相关(R=0.97,R2=0.94,p<0.00001),与萎陷伤相关(R=0.82,R2=0.70,p=0.00002)。
- SMP与应力相关(R=0.86,R2=0.75,p=0.00001),与应变相关(R=0.68,R2=0.47,p=0.001),与萎陷伤相关(R=0.67,R2=0.46,p=0.002)。
- 未标准化的MPRS仅在与充气肺大小标准化后才与VILI相关机制正相关。
适用人群与场景
- 18例ARDS患者,在三级学术ICU接受机械通气。
诊断标准与关键阈值
- 应变定义为潮气量与呼气末肺容积之比(strain = Vt/EELV)。
- 应力定义为吸气末跨肺压。
- 萎陷伤定义为呼气与吸气之间非充气肺的差值。
- SLMP = MPTp/EELV;SMP = MPRS/CRS。
处置流程与药物剂量
- 调整通气设置以达到相似的MPRS。
研究设计与关键结果
- 前瞻性队列研究,纳入18例ARDS患者,调整通气使MPRS相近(23.75(23-24)J/min)和MPTp相近(11.6(10.8-12.8)J/min)。
- SLMP随PaO2/FiO2下降而线性升高(R=-0.83,p=0.0001)。
- SLMP与应力相关(R=0.9,R2=0.84,p=0.00004),与应变相关(R=0.97,R2=0.94,p<0.00001),与萎陷伤相关(R=0.82,R2=0.70,p=0.00002)。
- SMP与应力相关(R=0.86,R2=0.75,p=0.00001),与应变相关(R=0.68,R2=0.47,p=0.001),与萎陷伤相关(R=0.67,R2=0.46,p=0.002)。
证据类型、等级与局限
- 证据类型:前瞻性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,将机械功率按充气肺大小或呼吸系统顺应性标准化,可能与应力、应变和萎陷伤正相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: First, to investigate whether the severity of acute respiratory distress syndrome (ARDS) influences ventilator-induced lung injury (VILI) risk in ventilated patients with similar mechanical power of respiratory system (MPRS). Second, to determine whether, under these circumstances, there is a relationship between transpulmonary mechanical power (MPTp) normalized to the aerated lung (specific lung mechanical power or SLMP) and VILI risk, and third, to determine whether normalizing MPRS to compliance of respiratory system (CRS) can replace SLMP to bedside.
DESIGN: Prospective cohort study.
SETTING: The study was conducted in a tertiary academic ICU.
PATIENTS: The study included 18 patients with ARDS.
INTERVENTIONS: Ventilatory settings were adjusted to achieve a similar MPRS.
MEASUREMENTS AND MAIN RESULTS: Mechanical power was normalized to CRS (specific mechanical power or SMP = MPRS/CRS), and SLMP was calculated as the ratio between MPTp and end-expiratory lung volume (SLMP = MPTp/EELV). The strain was defined as the ratio between tidal volume and EELV (strain = Vt/EELV), stress as transpulmonary pressure at the end of inspiration, and atelectrauma as the difference between expiration and inspiration in the nonaerated lung. Although patients had been ventilated with similar MPRS = 23.75 (23-24) J/min and MPTp = 11.6 (10.8-12.8) J/min, SLMP increased linearly with the fall in Pao2/Fio2 (R = -0.83, p = 0.0001). MPRS only correlated positively with VILI-associated mechanisms when normalized to aerated lung size: correlations between SLMP and stress (R = 0.9, R2 = 0.84, p = 0.00004), strain (R = 0.97, R2 = 0.94, p < 0.00001) and atelectrauma (R = 0.82, R2 = 0.70, p = 0.00002), and correlations between SMP and stress (R = 0.86, R2 = 0.75, p = 0.00001), strain (R = 0.68, R2 = 0.47, p = 0.001) and atelectrauma (R = 0.67, R2 = 0.46, p = 0.002).
CONCLUSIONS: The results suggest that normalizing mechanical power to lung-aerated size or CRS may correlate positively with stress, strain, and atelectrauma.
参考来源
- Pistillo N, Castelluccio P, Suzuki I, et al. Mechanical Power Correlates With Stress, Strain, and Atelectrauma Only When Normalized to Aerated Lung Size in Patients With Acute Respiratory Distress Syndrome. Crit Care Explor. 2023. PMID: 37753234. doi:10.1097/CCE.0000000000000982