咳嗽声学测量预测拔管失败:SonoWean 概念验证研究
本研究为概念验证研究,纳入机械通气超过 24 小时且完成 T 管自主呼吸试验成功的患者 106 例,在试验结束时用声级计对三次连续咳嗽进行定量声学评估,取三次咳嗽音量(分贝)均值作为 Sonoscore。拔管失败 15 例(14%)。拔管失败组 Sonoscore 显著低于成功组(58 [52-64] vs. 75 [70-78] dB,P < 0.001),校正机械通气时间和合并症后仍与拔管失败相关。Sonoscore 预测拔管失败的 ROC 曲线下面积为 0.91(95%CI [0.83-0.99],P < 0.001),阈值 < 67.1 dB 预测拔管失败的灵敏度 0.93(95%CI [0.70-0.99])、特异度 0.82(95%CI [0.73-0.90])。作者认为咳嗽声学评估可能有助于识别拔管失败风险患者。
要点
- 在通过 T 管自主呼吸试验的机械通气患者中,拔管失败组 Sonoscore 为 58 [52-64] dB,显著低于拔管成功组的 75 [70-78] dB(P < 0.001)。
- Sonoscore 预测拔管失败的 ROC 曲线下面积为 0.91(95%CI [0.83-0.99],P < 0.001)。
- 阈值 Sonoscore < 67.1 dB 预测拔管失败,灵敏度 0.93(95%CI [0.70-0.99])、特异度 0.82(95%CI [0.73-0.90])。
- 校正机械通气时间和合并症后,Sonoscore 仍与拔管失败相关。
- 本研究为概念验证研究,作者认为咳嗽声学评估可能有助于识别拔管失败风险患者。
适用人群与场景
- 接受有创机械通气超过 24 小时、完成 T 管自主呼吸试验(SBT)成功的患者。
- 研究纳入 106 例患者,中位年龄 65 [51-75] 岁,男性占 60%。
- 主要机械通气原因为急性呼吸衰竭(43%)、昏迷(25%)和休克(17%)。
- 入组时中位机械通气时间为 4 [3-7] 天。
诊断标准与关键阈值
- Sonoscore 为三次连续咳嗽音量(分贝)的均值,在 T 管自主呼吸试验结束时用声级计测量。
- Sonoscore < 67.1 dB 预测拔管失败,灵敏度 0.93(95%CI [0.70-0.99])、特异度 0.82(95%CI [0.73-0.90])。
研究设计与关键结果
- 研究类型:概念验证研究(SonoWean),纳入 106 例机械通气超过 24 小时且 T 管自主呼吸试验成功的患者。
- 拔管失败发生 15 例(14%)。
- 拔管成功组与失败组基线特征相似,但拔管失败组简单脱机比例更低、机械通气时间更长。
- 拔管失败组 Sonoscore 为 58 [52-64] dB,拔管成功组为 75 [70-78] dB,拔管失败组显著低于成功组(P < 0.001)。
- 校正机械通气时间和合并症后,Sonoscore 仍与拔管失败相关。
- Sonoscore 预测拔管失败的 ROC 曲线下面积为 0.91(95%CI [0.83-0.99],P < 0.001)。
- 阈值 Sonoscore < 67.1 dB 预测拔管失败,灵敏度 0.93(95%CI [0.70-0.99])、特异度 0.82(95%CI [0.73-0.90])。
证据类型、等级与局限
- 证据类型:概念验证研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,咳嗽声学评估可能有助于识别接受有创机械通气患者中拔管失败风险较高者。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Extubation failure is associated with increased mortality. Cough ineffectiveness may be associated with extubation failure, but its quantification for patients undergoing weaning from invasive mechanical ventilation (IMV) remains challenging.
METHODS: Patients under IMV for more than 24 h completing a successful spontaneous T-tube breathing trial (SBT) were included. At the end of the SBT, we performed quantitative sonometric assessment of three successive coughing efforts using a sonometer. The mean of the 3-cough volume in decibels was named Sonoscore.
RESULTS: During a 1-year period, 106 patients were included. Median age was 65 [51-75] years, mainly men (60%). Main reasons for IMV were acute respiratory failure (43%), coma (25%) and shock (17%). Median duration of IMV at enrollment was 4 [3-7] days. Extubation failure occurred in 15 (14%) patients. Baseline characteristics were similar between success and failure extubation groups, except percentage of simple weaning which was lower and MV duration which was longer in extubation failure patients. Sonoscore was significantly lower in patients who failed extubation (58 [52-64] vs. 75 [70-78] dB, P < 0.001). After adjustment on MV duration and comorbidities, Sonoscore remained associated with extubation failure. Sonoscore was predictive of extubation failure with an area under the ROC curve of 0.91 (IC95% [0.83-0.99], P < 0.001). A threshold of Sonoscore < 67.1 dB predicted extubation failure with a sensitivity of 0.93 IC95% [0.70-0.99] and a specificity of 0.82 IC95% [0.73-0.90].
CONCLUSION: Sonometric assessment of cough strength might be helpful to identify patients at risk of extubation failure in patients undergoing IMV.
参考来源
- Bonny V, Joffre J, Gabarre P, et al. Sonometric assessment of cough predicts extubation failure: SonoWean-a proof-of-concept study. Crit Care. 2023. PMID: 37749612. doi:10.1186/s13054-023-04653-w
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。