重症患者膈肌超声评估预测有创机械通气需求
本研究为前瞻性研究,纳入2021年5月20日至2022年5月19日期间就诊于急诊科、年龄≥18岁且在到达后10分钟内完成右侧膈肌移动度(RDE)测量的重症患者314例,其中113例(35.9%)需要有创机械通气(IMV)。RDE每增加0.1 cm是IMV的独立预测因子(校正OR 0.08,95%CI 0.04-0.17,p<0.001;AUROC 0.850,95%CI 0.807-0.894)。RDE截断值为1.2 cm(敏感性82.3%,95%CI 74.0-88.8;特异性78.1%,95%CI 71.7-83.6)。RDE≤1.2 cm时机械通气时间显著延长(13天[四分位距5, 27] vs 5天[四分位距3, 8],p=0.006)。作者认为RDE对预测IMV需求有良好能力,最佳截断值为1.2 cm,但其在患者管理中的获益需进一步研究。
要点
- 急诊就诊10分钟内测量右侧膈肌移动度(RDE),RDE每增加0.1 cm,需要有创机械通气的校正OR为0.08(95%CI 0.04-0.17,p<0.001)。
- RDE预测有创机械通气的AUROC为0.850(95%CI 0.807-0.894),截断值1.2 cm,敏感性82.3%(95%CI 74.0-88.8),特异性78.1%(95%CI 71.7-83.6)。
- RDE≤1.2 cm组机械通气时间显著长于RDE>1.2 cm组(13天[四分位距5, 27] vs 5天[四分位距3, 8],p=0.006)。
- 314例重症患者中113例(35.9%)需要有创机械通气。
- 作者认为RDE对预测IMV需求有良好能力,最佳截断值1.2 cm,但其在患者管理中的获益需进一步研究。
适用人群与场景
- 年龄≥18岁、就诊于急诊科的重症患者,且在到达后10分钟内完成右侧膈肌移动度(RDE)测量。
诊断标准与关键阈值
- RDE截断值1.2 cm用于预测需要有创机械通气(敏感性82.3%,95%CI 74.0-88.8;特异性78.1%,95%CI 71.7-83.6)。
研究设计与关键结果
- 前瞻性研究纳入314例急诊重症患者,113例(35.9%)需要有创机械通气。
- RDE每增加0.1 cm是IMV的独立预测因子(校正OR 0.08,95%CI 0.04-0.17,p<0.001;AUROC 0.850,95%CI 0.807-0.894)。
- RDE≤1.2 cm组机械通气时间13天(四分位距5, 27) vs RDE>1.2 cm组5天(四分位距3, 8),p=0.006。
证据类型、等级与局限
- 证据类型:前瞻性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为RDE对预测重症患者需要有创机械通气有良好能力,最佳截断值为1.2 cm,但其在患者管理中的获益需进一步研究。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Diaphragm dysfunction is common in critically ill patients and associated with poorer outcomes. The function of the diaphragm can be evaluated at the bedside by measuring diaphragmatic excursion using ultrasonography. In this study, we investigated the ability of right-sided diaphragmatic excursion (RDE) to predict the need for invasive mechanical ventilation (IMV).
METHODS: Critically ill patients aged 18 years and older who presented to our emergency department between May 20, 2021 and May 19, 2022 and underwent measurement of RDE within 10 min of arrival were enrolled in this prospective study. The ability of RDE to predict the need for IMV was assessed by multivariable logistic regression and analysis of the area under the receiver-operating characteristic curve (AUROC).
RESULTS: A total of 314 patients were enrolled in the study; 113 (35.9%) of these patients required IMV. An increase of RDE value per each 0.1 cm was identified to be an independent predictor of IMV (adjusted odds ratio 0.08, 95% confidence interval [CI] 0.04-0.17, p < 0.001; AUROC 0.850, 95% CI 0.807-0.894). The RDE cutoff value was 1.2 cm (sensitivity 82.3%, 95% CI 74.0-88.8; specificity 78.1%, 95% CI 71.7-83.6). Time on a ventilator was significantly longer when the RDE was ≤ 1.2 cm (13 days [interquartile range 5, 27] versus 5 days [interquartile range 3, 8], p = 0.006).
CONCLUSIONS: In this study, RDE had a good ability to predict the need for IMV in critically ill patients. The optimal RDE cutoff value was 1.2 cm. Its benefit in patient management requires further investigation.
参考来源
- Suttapanit K, Wongkrasunt S, Savatmongkorngul S, et al. Ultrasonographic evaluation of the diaphragm in critically ill patients to predict invasive mechanical ventilation. J Intensive Care. 2023. PMID: 37726832. doi:10.1186/s40560-023-00690-3
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。