文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

家兔同步机械通气中单次降低辅助操作(LAM)估算跨肺驱动压并与食管囊测量比较

Estimation of transpulmonary driving pressure during synchronized mechanical ventilation using a single lower assist maneuver (LAM) in rabbits: a comparison to measurements made with an esophageal balloon.
PubMed 文献 · Crit Care · 2023-08-25
一句话结论家兔研究显示,同步机械通气时单次降低辅助操作(LAM)可估算跨肺驱动压,与食管囊测量相关性较强,但存在一定偏差。

研究在24只家兔中比较了神经同步辅助通气(NAVA和NPS)下用单次降低辅助操作(LAM)估算跨肺驱动压(PL_LAM)与食管囊实测值(PL_CMV、PL_PES)的一致性。共匹配1792次呼吸,PL_LAM与PL_CMV强相关(r=0.83),与PL_PES相关(r=0.77)。Bland-Altman分析显示PL_LAM与PL_CMV偏差0.49 cm H2O(1.96SD=3.09 cm H2O),与PL_PES偏差2.2 cm H2O(1.96SD=3.4 cm H2O)。结论认为LAM可在不测食管压的情况下估算跨肺驱动压,并遵循数学传递函数描述同步辅助期间的呼吸肌卸载。

要点

  • 在24只家兔神经同步辅助通气(NAVA/NPS)中,单次将辅助降为零(NPS 0 cm H2O或NAVA水平0 cm H2O/uV)的LAM呼吸可估算跨肺驱动压PL_LAM。
  • PL_LAM与受控通气实测PL_CMV强相关(r=0.83),与自主呼吸实测PL_PES相关(r=0.77)。
  • Bland-Altman分析:PL_LAM与PL_CMV偏差0.49 cm H2O(1.96SD=3.09 cm H2O);与PL_PES偏差2.2 cm H2O(1.96SD=3.4 cm H2O)。
  • LAM实施要求其Edi与辅助呼吸相似;随辅助水平增加,峰值Edi时Edi与PES的失耦联进行性增加。
  • 共1792次呼吸与被动通气滴定匹配(匹配潮气量,r=0.99)。

适用人群与场景

  • 24只自主呼吸并施加负荷的家兔,在神经同步辅助通气模式(NAVA和NPS)及受控通气模式(VC和PC)下进行研究。

诊断标准与关键阈值

  • LAM操作要求:LAM呼吸的Edi需与辅助呼吸相似。

处置流程与药物剂量

  • 在每个辅助水平进行两次独立的单次LAM呼吸:NPS模式将辅助急性设为0 cm H2O,NAVA模式将NAVA水平设为0 cm H2O/uV,持续一个呼吸周期。
  • NPS和NAVA滴定后,在神经肌肉阻滞下进行受控模式(VC和PC)滴定。
  • 将NAVA/NPS滴定的呼吸按流量和容量与VC或PC匹配。
  • 全程测量膈肌电活动(Edi)和食管压(PES)。

研究设计与关键结果

  • 研究类型:家兔实验研究;样本量24只;干预:神经同步辅助通气(NAVA和NPS)下进行单次LAM,并与受控通气(VC或PC)及自主呼吸(NAVA或NPS)的食管囊实测ΔPL比较。
  • 所有动物均成功完成NPS/NAVA滴定和LAM。
  • 1792次呼吸与被动通气滴定匹配(匹配潮气量,r=0.99)。
  • PL_LAM与PL_CMV强相关(r=0.83),与PL_PES相关(r=0.77)。
  • Bland-Altman分析:PL_LAM与PL_CMV偏差0.49 cm H2O,1.96SD=3.09 cm H2O;PL_LAM与PL_PES偏差2.2 cm H2O,1.96SD=3.4 cm H2O。
  • 峰值Edi时分析Edi和PES显示,随辅助水平增加,失耦联进行性增加。

证据类型、等级与局限

  • 证据类型:动物实验研究(家兔)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文结论:在同步机械通气中,LAM呼吸允许在不测量PES的情况下估算跨肺驱动压,并遵循数学传递函数描述同步辅助期间的呼吸肌卸载。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Mechanical ventilation is applied to unload the respiratory muscles, but knowledge about transpulmonary driving pressure (ΔPL) is important to minimize lung injury. We propose a method to estimate ΔPL during neurally synchronized assisted ventilation, with a simple intervention of lowering the assist for one breath ("lower assist maneuver", LAM).

METHODS: In 24 rabbits breathing spontaneously with imposed loads, titrations of increasing assist were performed, with two neurally synchronized modes: neurally adjusted ventilatory assist (NAVA) and neurally triggered pressure support (NPS). Two single LAM breaths (not sequentially, but independently) were performed at each level of assist by acutely setting the assist to zero cm H2O (NPS) or NAVA level 0 cm H2O/uV (NAVA) for one breath. NPS and NAVA titrations were followed by titrations in controlled-modes (volume control, VC and pressure control, PC), under neuro-muscular blockade. Breaths from the NAVA/NPS titrations were matched (for flow and volume) to VC or PC. Throughout all runs, we measured diaphragm electrical activity (Edi) and esophageal pressure (PES). We measured ΔPL during the spontaneous modes (PL_PES) and controlled mechanical ventilation (CMV) modes (PL_CMV) with the esophageal balloon. From the LAMs, we derived an estimation of ΔPL ("PL_LAM") using a correction factor (ratio of volume during the LAM and volume during assist) and compared it to measured ΔPL during passive (VC or PC) and spontaneous breathing (NAVA or NPS). A requirement for the LAM was similar Edi to the assisted breath.

RESULTS: All animals successfully underwent titrations and LAMs for NPS/NAVA. One thousand seven-hundred ninety-two (1792) breaths were matched to passive ventilation titrations (matched Vt, r = 0.99). PL_LAM demonstrated strong correlation with PL_CMV (r = 0.83), and PL_PES (r = 0.77). Bland-Altman analysis revealed little difference between the predicted PL_LAM and measured PL_CMV (Bias = 0.49 cm H2O and 1.96SD = 3.09 cm H2O). For PL_PES, the bias was 2.2 cm H2O and 1.96SD was 3.4 cm H2O. Analysis of Edi and PES at peak Edi showed progressively increasing uncoupling with increasing assist.

CONCLUSION: During synchronized mechanical ventilation, a LAM breath allows for estimations of transpulmonary driving pressure, without measuring PES, and follows a mathematical transfer function to describe respiratory muscle unloading during synchronized assist.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Liu L, Li HL, Lu C, et al. Estimation of transpulmonary driving pressure during synchronized mechanical ventilation using a single lower assist maneuver (LAM) in rabbits: a comparison to measurements made with an esophageal balloon. Crit Care. 2023. PMID: 37626372. doi:10.1186/s13054-023-04607-2

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。