文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

机械通气患者的经皮膈肌电刺激:一项随机研究

Transcutaneous electrical diaphragmatic stimulation in mechanically ventilated patients: a randomised study.
PubMed 文献 · Crit Care · 2023-08-30
一句话结论每日主动经皮膈肌电刺激与假刺激相比,未预防机械通气患者膈肌功能障碍,也未改善吸气肌力。

该研究纳入66例机械通气患者,按1:1随机分为每日主动经皮膈肌电刺激(TEDS)组与假刺激组,评估其对撤机过程中膈肌功能障碍的预防作用,主要依据自主呼吸试验时超声测量的膈肌增厚分数。结果:TEDS组67%的患者在自主呼吸试验时膈肌增厚分数>30%,假刺激组为54%(OR 1.55,95%CI 0.47-5.1;p=0.47);两组最大吸气压力(35.5±11.9 vs 29.7±11.7 cmH2O;p=0.469)和峰值咳嗽流量(83.2±39.5 vs 75.3±34.08 L/min;p=0.83)相似;两组拔管失败率无差异。结论:TEDS未能预防膈肌功能障碍或改善吸气肌力。

要点

  • TEDS组67%的患者在自主呼吸试验时膈肌增厚分数>30%,假刺激组为54%(OR 1.55,95%CI 0.47-5.1;p=0.47),差异未达统计学显著。
  • 两组最大吸气压力相似:TEDS组35.5±11.9 cmH2O vs 假刺激组29.7±11.7 cmH2O(p=0.469)。
  • 两组峰值咳嗽流量相似:TEDS组83.2±39.5 L/min vs 假刺激组75.3±34.08 L/min(p=0.83)。
  • 两组拔管失败率无差异。
  • 结论:TEDS未预防膈肌功能障碍或改善吸气肌力。

适用人群与场景

  • 机械通气患者,纳入撤机过程中预防膈肌功能障碍的评估。

诊断标准与关键阈值

  • 膈肌功能障碍评估依据自主呼吸试验时超声测量的膈肌增厚分数,以>30%为界值。

处置流程与药物剂量

  • 每日主动经皮膈肌电刺激(TEDS)与假刺激对照,用于撤机过程中预防膈肌功能障碍。

研究设计与关键结果

  • 研究类型:随机对照试验;样本量66例,按1:1随机分组;平均机械通气天数10±6.8天。
  • 主要终点:自主呼吸试验时膈肌增厚分数>30%的比例,TEDS组67% vs 假刺激组54%(OR 1.55,95%CI 0.47-5.1;p=0.47)。
  • 次要终点:最大吸气压力TEDS组35.5±11.9 cmH2O vs 假刺激组29.7±11.7 cmH2O(p=0.469);峰值咳嗽流量TEDS组83.2±39.5 L/min vs 假刺激组75.3±34.08 L/min(p=0.83)。
  • 拔管失败率两组无差异。

证据类型、等级与局限

  • 证据类型:随机对照试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论:TEDS未预防机械通气患者膈肌功能障碍或改善吸气肌力。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Few specific methods are available to reduce the risk of diaphragmatic dysfunction for patients under mechanical ventilation. The number of studies involving transcutaneous electrical stimulation of the diaphragm (TEDS) is increasing but none report results for diaphragmatic measurements, and they lack power. We hypothesised that the use of TEDS would decrease diaphragmatic dysfunction and improve respiratory muscle strength in patients in ICU.

METHODS: We conducted a controlled trial to assess the impact of daily active electrical stimulation versus sham stimulation on the prevention of diaphragm dysfunction during the weaning process from mechanical ventilation. The evaluation was based on ultrasound measurements of diaphragm thickening fraction during spontaneous breathing trials. We also measured maximal inspiratory muscle pressure (MIP), peak cough flow (PEF) and extubation failure.

RESULTS: Sixty-six patients were included and randomised using a 1:1 ratio. The mean number of days of mechanical ventilation was 10 ± 6.8. Diaphragm thickening fraction was > 30% at the SBT for 67% of participants in the TEDS group and 54% of the Sham group (OR1.55, 95% CI 0.47-5.1; p = 0.47). MIP and PEF were similar in the TEDS and Sham groups (respectively 35.5 ± 11.9 vs 29.7 ± 11.7 cmH20; p = 0.469 and 83.2 ± 39.5 vs. 75.3 ± 34.08 L/min; p = 0.83). Rate of extubation failure was not different between groups.

CONCLUSION: TEDS did not prevent diaphragm dysfunction or improve inspiratory muscle strength in mechanically ventilated patients.

TRIAL REGISTRATION: Prospectively registered on the 20th November 2019 on ClinicalTrials.gov Identifier NCT04171024.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Medrinal C, Machefert M, Lamia B, et al. Transcutaneous electrical diaphragmatic stimulation in mechanically ventilated patients: a randomised study. Crit Care. 2023. PMID: 37649092. doi:10.1186/s13054-023-04597-1

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。