经肝途径下腔静脉扩张性预测急诊剖腹术后脓毒性休克患者液体反应性的准确性
这项前瞻性观察研究纳入急诊剖腹术后脓毒性休克、机械通气且镇静的成人患者,分别经肝途径和剑突下途径测量下腔静脉尺寸,以500 mL液体负荷后心输出量增加>15%确认液体反应性。51例患者数据纳入分析,液体反应者30/52(58%);经肝途径全部患者可行,剑突下途径仅42例可行。经肝途径下腔静脉扩张性预测液体反应性的AUC为0.88(95%CI 0.76-0.95),与剑突下途径0.81(0.66-0.92)相当(P=0.417)。经肝途径灰区17%~35%涵盖24/51例(47%),剑突下途径灰区13%~34%涵盖18/42例(43%)。
要点
- 经肝途径下腔静脉扩张性预测液体反应性AUC 0.88(95%CI 0.76-0.95),与剑突下途径0.81(0.66-0.92)相当(P=0.417)。
- 经肝途径在全部51例患者中可行,剑突下途径仅42例可行,经肝途径可行性更高。
- 液体反应性以500 mL液体负荷后心输出量增加>15%确认,液体反应者30/52(58%)。
- 经肝途径灰区17%~35%涵盖24/51例(47%),剑突下途径灰区13%~34%涵盖18/42例(43%)。
适用人群与场景
- 急诊剖腹术后发生脓毒性休克、机械通气且镇静的成人患者。
诊断标准与关键阈值
- 液体反应性确认标准:500 mL液体负荷后心输出量增加>15%。
- 经肝途径下腔静脉扩张性灰区为17%~35%。
- 剑突下途径下腔静脉扩张性灰区为13%~34%。
研究设计与关键结果
- 研究类型:前瞻性观察研究;纳入51例患者数据进行分析,液体反应者30/52(58%)。
- 经肝途径在所有患者中可行,剑突下途径仅在42例患者中可行。
- 经肝途径下腔静脉扩张性预测液体反应性的AUC为0.88(95%CI 0.76-0.95),与剑突下途径0.81(95%CI 0.66-0.92)相当(P=0.417)。
- 经肝途径灰区17%~35%涵盖24/51例患者(47%);剑突下途径灰区13%~34%涵盖18/42例患者(43%)。
证据类型、等级与局限
- 证据类型:前瞻性观察研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,经肝途径评估下腔静脉扩张性在急诊剖腹术后脓毒性休克患者中预测液体反应性显示出良好准确性。
- 作者认为,经肝途径与剑突下途径准确性相同,且优势在于可在更多患者中可行。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Background: We aimed to evaluate the ability of inferior vena cava (IVC) distensibility using the transhepatic approach to predict fluid responsiveness in mechanically ventilated patients with septic shock after emergency laparotomy. Methods: This prospective observational study included mechanically ventilated paralyzed adult who had septic shock after emergency laparotomy. The IVC dimensions were measured through the transhepatic and subxiphoid approaches. The fluid responsiveness was confirmed with >15% increase in cardiac output after 500 mL of fluid bolus. The outcomes were the ability of transhepatic (primary outcome) and subxiphoid approach to predict fluid responders using the area under the receiver operating characteristics curve analysis. The gray zone for the two approaches was calculated. Results: Data from 51 patients were analyzed, and the number of fluid responders was 30 of 52 (58%). The transhepatic approach was feasible in all patients, whereas the subxiphoid approach was only feasible in 42 patients. The area under the receiver operating characteristics curve (95% confidence interval) for the transhepatic IVC distensibility was 0.88 (0.76-0.95), and it was comparable with that of the subxiphoid approach (0.81 [0.66-0.92], P = 0.417). The gray zone for the transhepatic IVC distensibility was 17% to 35% including 24 of 51 patients (47%), whereas the gray zone for the subxiphoid IVC distensibility was 13% to 34% including 18 of 42 patients (43%). Conclusion: In conclusion, the transhepatic approach for evaluation of IVC distensibility showed good accuracy in predicting fluid responsiveness in patients with septic shock after emergency laparotomy. The transhepatic approach showed the same accuracy as the subxiphoid approach with the advantage of being feasible in larger number of patients.
参考来源
- Hasanin A, Karam N, Mostafa M, et al. THE ACCURACY OF INFERIOR VENA CAVA DISTENSIBILITY THROUGH THE TRANSHEPATIC APPROACH TO PREDICT FLUID RESPONSIVENESS IN PATIENTS WITH SEPTIC SHOCK AFTER EMERGENCY LAPAROTOMY. Shock. 2023. PMID: 37625114. doi:10.1097/SHK.0000000000002212
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。