外科口罩对嘴通气作为心肺复苏中替代通气技术的交叉随机对照试验

Surgical mask-to-mouth ventilation as an alternative ventilation technique during CPR: A crossover randomized controlled trial.
PubMed 文献 · Am J Emerg Med · 2023-07-29
一句话结论在人体模型交叉随机对照试验中,外科口罩对嘴通气(SMV)产生的平均潮气量与嘴对嘴通气(MMV)相当,且志愿者实施意愿更高

该交叉随机对照试验将42名医务人员志愿者随机分配,依次实施四种通气技术:嘴对嘴通气(MMV,无防护装备)、外科口罩对嘴通气(SMV,施救者戴口罩)、嘴对外科口罩通气(MSV,模型戴口罩)和外科口罩对口罩通气(SSV,施救者与模型均戴口罩)。结果示MMV平均潮气量828±278 ml,显著高于MSV的648±250 ml(P<0.001)和SSV的466±301 ml(P<0.001),但与SMV的744±288 ml无显著差异(P=0.054)。MMV组有效通气比例144/168(85.7%),显著高于SMV组77.4%(P=0.02)、MSV组66.7%(P<0.001)和SSV组39.3%(P<0.001)。实施SMV的意愿高于实施MMV。作者认为,SMV可达到与MMV相当的平均潮气量。

要点

  • 在人体模型上,SMV(施救者戴口罩)平均潮气量744±288 ml,与MMV的828±278 ml无显著差异(P=0.054)。
  • MMV有效通气比例144/168(85.7%),显著高于SMV的77.4%(P=0.02)、MSV的66.7%(P<0.001)和SSV的39.3%(P<0.001)。
  • MMV平均潮气量828±278 ml,显著高于MSV的648±250 ml(P<0.001)和SSV的466±301 ml(P<0.001)。
  • 志愿者实施SMV的意愿高于实施MMV。

适用人群与场景

  • 42名医务人员志愿者,在人体模型上实施通气技术比较。

研究设计与关键结果

  • 研究类型:交叉随机对照试验,42名医务人员志愿者在人体模型上随机实施四种通气技术:MMV(无防护装备)、SMV(施救者戴口罩)、MSV(模型戴口罩)、SSV(施救者与模型均戴口罩)。
  • 主要终点:MMV平均潮气量828±278 ml,显著高于MSV的648±250 ml(P<0.001)和SSV的466±301 ml(P<0.001),但与SMV的744±288 ml无显著差异(P=0.054)。
  • 有效通气比例:MMV组144/168(85.7%),显著高于SMV组77.4%(P=0.02)、MSV组66.7%(P<0.001)和SSV组39.3%(P<0.001)。
  • 志愿者实施SMV的意愿高于实施MMV。

证据类型、等级与局限

  • 证据类型:交叉随机对照试验;局限:原文未报告局限性。

对床旁实践的改变

  • 在人体模型上,SMV产生的平均潮气量与MMV相当,且志愿者实施SMV的意愿高于MMV。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Chest compression with rescue breathing improves outcomes in cardiac arrest. However, the efficacy of rescue breathing through surgical masks has not been investigated.

OBJECTIVE: We aimed to compare the tidal volume generated by mouth-to-mouth ventilation (MMV) with that generated by surgical mask-to-mouth ventilation (SMV), mouth-to-surgical mask ventilation (MSV), and surgical mask-to-surgical mask ventilation (SSV) in a manikin.

METHODS: A crossover randomized controlled trial was conducted in 42 medical personnel volunteers randomly assigned to perform four ventilation techniques: MMV (no protective equipment), SMV (participant wearing a mask), MSV (manikin wearing a mask), and SSV, (both participant and manikin wearing a mask). The average tidal volume and the proportion of adequate ventilation, evaluated using a manikin, were compared across different ventilation methods.

RESULTS: The average tidal volume of MMV (828 ± 278 ml) was significantly higher than those of the MSV (648 ± 250 ml, P < 0.001) and SSV (466 ± 301 ml, P < 0.001), but not SMV (744 ± 288 ml, P = 0.054). Adequate ventilation was achieved in 144/168 (85.7%) cases in the MMV group, a proportion significantly higher than in the SMV (77.4%, P = 0.02), MSV (66.7%, P < 0.001) and SSV (39.3%, P < 0.001) groups. The willingness to perform SMV was higher than that to perform MMV.

CONCLUSIONS: MMV resulted in a superior average tidal volume when compared to both MSV and SSV. However, SMV achieved a comparable average tidal volume to MMV.