文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

面向个体化机械通气的计算生理学模型:系统文献综述,聚焦质量、可用性与临床就绪度

Computational physiological models for individualised mechanical ventilation: a systematic literature review focussing on quality, availability, and clinical readiness.
PubMed 文献 · Crit Care · 2023-07-06
一句话结论计算生理学模型正朝临床可解释工具发展,但93%文章报告模型设计质量不满意、仅21%报告质量不满意,仅3项RCT启动。

该系统综述于2023年2月13日检索MEDLINE ALL、Embase、Scopus与Web of Science,从6333篇文献中纳入149篇描述ICU个体化机械通气计算生理学模型(CPM)的原创研究。CPM自1970年代出现且就绪度逐步提高;131篇(88%)建模肺力学,主要用于肺保护性通气;气体交换模型38篇(26%)、气体稳态模型36篇(24%)主要用于控制氧合与通气;用于膈肌保护性通气的呼吸肌功能模型近期出现3篇(2%)。仅3项随机对照试验启动,应用Beacon与CURE Soft模型进行气体交换与PEEP优化。总体模型设计报告与质量分别有93%和21%的文章报告不满意。

要点

  • 149篇纳入文献中131篇(88%)建模肺力学,主要用于肺保护性通气。
  • 气体交换模型38篇(26%)、气体稳态模型36篇(24%),主要用于控制氧合与通气。
  • 针对膈肌保护性通气的呼吸肌功能模型近期仅3篇(2%)。
  • 仅3项随机对照试验启动,应用Beacon与CURE Soft模型优化气体交换与PEEP。
  • 模型设计与质量报告分别有93%和21%的文章报告不满意。

适用人群与场景

  • ICU内接受机械通气的患者,用于个体化优化机械通气设置。

研究设计与关键结果

  • 系统文献综述:2023年2月13日检索MEDLINE ALL、Embase、Scopus与Web of Science,从6333篇独特文献中纳入149篇描述ICU个体化机械通气CPM的原创研究。
  • CPM自1970年代出现,就绪度逐步提高。
  • 131篇(88%)建模肺力学,主要用于肺保护性通气。
  • 气体交换模型38篇(26%)与气体稳态模型36篇(24%),主要用于控制氧合与通气。
  • 用于膈肌保护性通气的呼吸肌功能模型近期出现3篇(2%)。
  • 3项随机对照试验启动,应用Beacon与CURE Soft模型进行气体交换与PEEP优化。
  • 模型设计报告与质量分别有93%和21%的文章报告不满意。

证据类型、等级与局限

  • 证据类型:系统文献综述(PROSPERO注册号CRD42022301715,注册日期2022年2月5日)。
  • 模型设计报告质量依据美国机械工程师学会(ASME)标准评估。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为CPM正发展成为优化个体化机械通气的可解释工具。
  • 作者认为为促进临床转化,需要专门的质量评估与模型报告标准。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Individualised optimisation of mechanical ventilation (MV) remains cumbersome in modern intensive care medicine. Computerised, model-based support systems could help in tailoring MV settings to the complex interactions between MV and the individual patient's pathophysiology. Therefore, we critically appraised the current literature on computational physiological models (CPMs) for individualised MV in the ICU with a focus on quality, availability, and clinical readiness.

METHODS: A systematic literature search was conducted on 13 February 2023 in MEDLINE ALL, Embase, Scopus and Web of Science to identify original research articles describing CPMs for individualised MV in the ICU. The modelled physiological phenomena, clinical applications, and level of readiness were extracted. The quality of model design reporting and validation was assessed based on American Society of Mechanical Engineers (ASME) standards.

RESULTS: Out of 6,333 unique publications, 149 publications were included. CPMs emerged since the 1970s with increasing levels of readiness. A total of 131 articles (88%) modelled lung mechanics, mainly for lung-protective ventilation. Gas exchange (n = 38, 26%) and gas homeostasis (n = 36, 24%) models had mainly applications in controlling oxygenation and ventilation. Respiratory muscle function models for diaphragm-protective ventilation emerged recently (n = 3, 2%). Three randomised controlled trials were initiated, applying the Beacon and CURE Soft models for gas exchange and PEEP optimisation. Overall, model design and quality were reported unsatisfactory in 93% and 21% of the articles, respectively.

CONCLUSION: CPMs are advancing towards clinical application as an explainable tool to optimise individualised MV. To promote clinical application, dedicated standards for quality assessment and model reporting are essential. Trial registration number PROSPERO- CRD42022301715 . Registered 05 February, 2022.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Warnaar RSP, Mulder MP, Fresiello L, et al. Computational physiological models for individualised mechanical ventilation: a systematic literature review focussing on quality, availability, and clinical readiness. Crit Care. 2023. PMID: 37415253. doi:10.1186/s13054-023-04549-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。