文献速递心脑血管急症

0/1小时心肌肌钙蛋白算法在急诊诊断非ST段抬高型心肌梗死的临床性能

Clinical performance of 0/1 h cardiac troponin algorithm for diagnosing non-STEMI in an emergency setting.
PubMed 文献 · Am J Emerg Med · 2023-06-24
一句话结论单中心前瞻性队列显示,基于实验室的Roche Modular E170 hs-cTnT与Radiometer AQT90-flex POCT cTnT采用0/1小时算法诊断NSTEMI的准确性相当。

该单中心前瞻性观察性队列研究在陕西省人民医院急诊科纳入未分化胸痛患者,评估基于实验室的Roche Modular E170 hs-cTnT与Radiometer AQT90-flex POCT cTnT采用0/1小时算法诊断NSTEMI的分析与诊断性能。基线与1小时后同时采集全血样本测定hs-cTnT与POCT cTnI。结果显示,POCT cTnT采用0/1小时算法诊断NSTEMI的准确性可与实验室hs-cTnT相当。作者认为实验室hs-cTnT联合0/1小时算法是可靠准确的诊断方法,POCT cTnT周转快,有助于加快胸痛患者的诊断流程。

要点

  • 单中心前瞻性观察性队列在急诊未分化胸痛患者中评估0/1小时算法诊断NSTEMI。
  • POCT cTnT采用0/1小时算法诊断NSTEMI的准确性可与实验室Roche Modular E170 hs-cTnT相当。
  • POCT cTn测定可在15分钟内为医生提供肌钙蛋白读数。
  • 作者认为实验室hs-cTnT联合0/1小时算法是诊断急诊未分化胸痛患者NSTEMI可靠且准确的方法。
  • 作者认为POCT cTnT周转快,是加快胸痛患者诊断流程的有价值工具。

适用人群与场景

  • 就诊于急诊科的未分化胸痛患者,来自陕西省人民医院单中心。

处置流程与药物剂量

  • 基线与1小时后同时采集全血样本,测定hs-cTnT与POCT cTnI,采用0/1小时算法。
  • POCT cTn测定可在15分钟内为医生提供肌钙蛋白读数。

研究设计与关键结果

  • 研究类型为单中心前瞻性观察性队列研究,在陕西省人民医院急诊科纳入未分化胸痛患者。
  • 评估基于实验室的Roche Modular E170 hs-cTnT与Radiometer AQT90-flex POCT cTnT采用0/1小时算法的分析与诊断性能。
  • 基线与1小时后同时采集全血样本测定hs-cTnT与POCT cTnI。
  • POCT cTnT采用0/1小时算法诊断NSTEMI的准确性可与实验室Roche Modular E170 hs-cTnT相当。

证据类型、等级与局限

  • 证据类型:单中心前瞻性观察性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为实验室hs-cTnT联合0/1小时算法是诊断急诊未分化胸痛患者NSTEMI可靠且准确的方法。
  • 作者认为POCT cTnT诊断准确性可与hs-cTnT相当,且周转快,是加快胸痛患者诊断流程的有价值工具。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Non-ST-segment elevation myocardial infarction (NSTEMI) is a common form of acute myocardial infarction and rapid and accurate diagnosis is crucial for timely treatment. Current guidelines recommend using high-sensitivity cardiac troponin (hs-cTn) assays to determine circulating cTnI or cTnT levels. While the accuracy of the 0 h/1 h algorithm for diagnosing NSTEMI in different regions and patient populations remains controversial. Additionally, point-of-care testing (POCT) cTn assays have the potential to provide troponin readings to physicians within 15 min, but their accuracy in diagnosing NSTEMI in the emergency department (ED) requires further investigation.

METHODS: A single-center prospective observational cohort study was conducted at Shaanxi Provincial People's Hospital to assess the analytical and diagnostic performance of the laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm with Radiometer AQT90-flex POCT cTnT assay in undifferentiated chest pain patients presenting to the ED. Whole-blood samples were collected and hs-cTnT and POCT cTnI were measured simultaneously at baseline and after 1 h.

RESULTS: The study results showed that the POCT cTnT assay using the 0 h/1 h algorithm had comparable diagnostic accuracy to the laboratory-based Roche Modular E170 hs-cTnT assay in diagnosing NSTEMI in patients with chest pain.

CONCLUSION: The laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm is reliable and accurate method for diagnosing NSTEMI in undifferentiated chest pain patients presenting to the ED. POCT cTnT assay has comparable diagnostic accuracy to the hs-cTnT assay and its rapid turnaround time makes it a valuable tool in expediting the diagnostic workup of chest pain patients.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Gou Q, Liang L, Liu D, et al. Clinical performance of 0/1 h cardiac troponin algorithm for diagnosing non-STEMI in an emergency setting. Am J Emerg Med. 2023. PMID: 37392513. doi:10.1016/j.ajem.2023.06.036

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。