文献速递心脑血管急症

高敏肌钙蛋白加速诊断方案实施后心脏检查的频率、依从性与检出率

Frequency, compliance, and yield of cardiac testing after high-sensitivity troponin accelerated diagnostic protocol implementation.
PubMed 文献 · Am J Emerg Med · 2023-07-13
一句话结论高敏肌钙蛋白联合更新加速诊断方案实施后,急诊胸痛患者后续负荷试验或冠状动脉CT血管成像检查率下降,方案依从率降低但检出率未显著变化。

该研究利用电子健康记录,比较了五个急诊科在换用高敏肌钙蛋白检测及更新加速诊断方案前后各1年的胸痛就诊情况。共7564例次胸痛就诊,前期3665例次、后期3899例次。更新方案实施后,后续检查率从每100例次27.8例次降至23.5例次(P<0.001),接受检查者中方案依从率从80.9%降至46.5%(P<0.001),检查检出率从24.5%升至29.2%(P=0.07),非依从检查的检出率前后相似(13.0% vs 15.4%,P=0.43)。结论认为高敏肌钙蛋白联合更新加速诊断方案的实施与负荷试验及冠状动脉CT血管成像检查率降低相关。

要点

  • 五个急诊科换用高敏肌钙蛋白并更新加速诊断方案后,胸痛患者后续负荷试验或冠状动脉CT血管成像检查率从每100例次27.8例次降至23.5例次(P<0.001)。
  • 在接受后续检查的患者中,加速诊断方案依从率从80.9%降至46.5%(P<0.001)。
  • 接受检查者的诊断检出率从24.5%升至29.2%,差异未达统计学显著(P=0.07)。
  • 不符合加速诊断方案指导的检查,其检出率在方案更新前后相似(13.0% vs 15.4%,P=0.43)。
  • 研究结论:高敏肌钙蛋白联合更新加速诊断方案的实施与负荷试验和冠状动脉CT血管成像检查率降低相关。

适用人群与场景

  • 因胸痛就诊于五个急诊科的患者,急诊科隶属于一个整合学术卫生系统。
  • 比较高敏肌钙蛋白检测换用前1年与换用后1年的胸痛就诊例次。

研究设计与关键结果

  • 研究类型:利用电子健康记录比较高敏肌钙蛋白检测及更新加速诊断方案实施前后各1年的胸痛就诊情况。
  • 样本量:共7564例次胸痛就诊,高敏肌钙蛋白前时期3665例次,后时期3899例次。
  • 主要终点:更新加速诊断方案实施后,后续检查率为每100例次23.5例次(862例次),前时期为每100例次27.8例次(1085例次),P<0.001。
  • 在接受检查者中,方案依从率从80.9%降至46.5%(P<0.001)。
  • 接受检查者的诊断检出率从24.5%升至29.2%(P=0.07)。
  • 不符合加速诊断方案指导的检查,检出率前后相似:前13.0%,后15.4%(P=0.43)。

证据类型、等级与局限

  • 证据类型:利用电子健康记录的观察性研究,比较高敏肌钙蛋白检测及更新加速诊断方案实施前后。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在高敏肌钙蛋白联合更新加速诊断方案实施后,急诊胸痛患者接受负荷试验或冠状动脉CT血管成像的比例可能降低。
  • 实施更新加速诊断方案后,接受后续检查者中方案依从率下降,临床需关注加速诊断方案的实际执行情况。
  • 接受检查者的诊断检出率从24.5%升至29.2%,但差异未达统计学显著(P=0.07)。
  • 不符合加速诊断方案指导的检查,其检出率前后相似(13.0% vs 15.4%,P=0.43)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Among persons presenting to the emergency department with suspected acute myocardial infarction (MI), cardiac troponin (cTn) testing is commonly used to detect acute myocardial injury. Accelerated diagnostic protocols (ADPs) guide clinicians to integrate cTn results with other clinical information to decide whether to order further diagnostic testing.

OBJECTIVE: To determine the change in the rate and yield of stress test or coronary CT angiogram following cTn measurement in patients with chest pain presenting to the emergency department pre- and post-transition to a high-sensitivity (hs-cTn) assay in an updated ADP.

METHODS: Using electronic health records, we examined visits for chest pain at five emergency departments affiliated with an integrated academic health system 1-year pre- and post-hs-cTn assay transition. Outcomes included stress test or coronary imaging frequency, ADP compliance among those with additional testing, and diagnostic yield (ratio of positive tests to total tests).

RESULTS: There were 7564 patient-visits for chest pain, including 3665 in the pre- and 3899 in the post-period. Following the updated ADP using hs-cTn, 862 (23.5 per 100 patient visits) visits led to subsequent testing versus 1085 (27.8 per 100 patient visits) in the pre-hs-cTn period, (P < 0.001). Among those who were tested, the protocol-compliant rate fell from 80.9% to 46.5% (P < 0.001), but the yield of those tests rose from 24.5% to 29.2% (P = 0.07). Among tests that were noncompliant with ADP guidance, yield was similar pre- and post-updated hs-cTn ADP implementation (pre 13.0%, post 15.4% (P = 0.43).

CONCLUSION: Implementation of hs-cTn supported by an updated ADP was associated with a lower rate of stress testing and coronary CT angiogram.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Baugh CW, Blankstein R, Ganguli I, et al. Frequency, compliance, and yield of cardiac testing after high-sensitivity troponin accelerated diagnostic protocol implementation. Am J Emerg Med. 2023. PMID: 37494772. doi:10.1016/j.ajem.2023.07.014

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。