文献速递心脑血管急症重症综合管理与镇静镇痛

融合影像估计大脑半球梗死颅内压与组织移位

TCCD Fusion Imaging to Estimate Intracranial Pressure and Tissue Displacement with Large Hemispheric Infarction.
PubMed 文献 · Neurocrit Care · 2023-07-06
一句话结论融合影像(经颅彩色多普勒叠加CT血管成像)诊断3 mm组织移位的敏感性100%、特异性95%,且无副作用或与重症监护设备交互。

本文评估融合影像(将经颅彩色双功超声叠加于CT血管成像或磁共振扫描)用于大脑半球梗死患者床旁监测组织移位与颅内压的可行性。患者接受多次融合影像检查并对照标准CT影像。结果显示融合影像诊断3 mm移位的敏感性为100%,特异性为95%,未记录副作用或与重症监护设备的交互。作者认为融合影像易于获取测量,可能为指示去骨瓣减压术提供决定性支持。

要点

  • 融合影像将经颅彩色双功超声实时叠加于CT或磁共振扫描,用于大脑半球梗死患者的床旁监测。
  • 诊断3 mm组织移位的敏感性100%、特异性95%。
  • 未记录副作用或与重症监护设备的交互。
  • 作者认为融合影像可能为指示去骨瓣减压术提供决定性支持。

适用人群与场景

  • 大脑半球梗死患者,包括不适合转运的患者,用于床旁监测单侧组织移位。

处置流程与药物剂量

  • 使用融合影像将经颅彩色双功超声叠加于CT血管成像,实时超声叠加于CT或磁共振扫描。
  • 利用源文件位置数据与实时影像匹配,并关联患者前额磁性探头与超声探头。
  • 分析脑实质移位、大脑前动脉、基底动脉及第三脑室移位、中脑压力以及基底动脉在头部的移位。
  • 患者在标准治疗CT影像之外接受多次融合影像检查。

研究设计与关键结果

  • 融合影像诊断3 mm移位的敏感性为100%,特异性为95%。
  • 未记录副作用或与重症监护设备的交互。

证据类型、等级与局限

  • 局限:原文未报告局限性。

对床旁实践的改变

  • 融合影像易于获取测量,可用于重症监护患者及卒中后组织与血管移位的随访。
  • 作者认为融合影像可能为指示去骨瓣减压术提供决定性支持。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Despite breakthroughs in stroke treatment, some patients still experience large infarctions of the cerebral hemispheres resulting in mass effect and tissue displacement. The evolution of mass effect is currently monitored using serial computed tomography (CT) imaging. However, there are patients who are ineligible for transport, and there are limited options for bedside monitoring of unilateral tissue shift.

METHODS: We used fusion imaging for overlaying transcranial color duplex with CT angiography. This method allows overlay of live ultrasound on top of CT or magnetic resonance imaging scans. Patients with large hemispheric infarctions were eligible to participate. Position data from the source files were used and matched with live imaging and correlation to magnetic probes on the patient's forehead and ultrasound probe. Shift of cerebral parenchyma, displacement of the anterior cerebral arteries, basilary artery and third ventricle were analyzed, as well as pressure on the midbrain, and the displacement of the basilar artery on the head were analyzed. Patients received multiple examinations in addition to standard care of treatment with CT imaging.

RESULTS: The sensitivity for diagnosing a shift of 3 mm with fusion imaging was 100%, with a specificity of 95%. No side effects or interactions with critical care equipment were recorded.

CONCLUSIONS: Fusion imaging is an easy method to access and acquire measurements for critical care patients and follow-up of tissue and vascular displacement after stroke. Fusion imaging may be a decisive support for indicating hemicraniectomy.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Mausbach S, van Spankeren T, Hudel H, et al. TCCD Fusion Imaging to Estimate Intracranial Pressure and Tissue Displacement with Large Hemispheric Infarction. Neurocrit Care. 2023. PMID: 37415022. doi:10.1007/s12028-023-01784-4

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。