PubMed 文献 · Resuscitation · 2023-07-04
一句话结论瑞典多数急救呼叫在AHA绩效目标内应答,院外心脏骤停呼叫中救护车在70秒内派出者30天生存率10.8%,高于超过100秒派出者的9.3%(p=0.0013)。

该观察性研究利用瑞典心肺复苏登记处与紧急医疗调度中心数据,评估瑞典调度中心在10年间对院外心脏骤停呼叫的应答与派车能否达到美国心脏协会(AHA)绩效目标,并比较一步法(呼叫直接接入调度中心)与二步法(呼叫转接至区域调度中心)流程。共应答9,174,940次医疗呼叫,中位应答延迟7.3秒;二步法转接594,008次(6.1%),中位应答延迟39秒。一步法登记的45,367例院外心脏骤停中位应答延迟7.2秒(AHA高性能目标10秒),应答延迟与30天生存无差异;救护车中位派出时间111.9秒,70秒内派出者30天生存率10.8%(n=664),超过100秒派出者9.3%(n=2174)(p=0.0013)。二步法流程的结局数据无法获取。

要点

  • 一步法院外心脏骤停呼叫中位应答延迟7.2秒(IQR 3.6-14.1秒),达到AHA高性能目标10秒。
  • 一步法院外心脏骤停救护车中位派出时间111.9秒(IQR 81.7-159.9秒)。
  • 救护车在70秒内(AHA高性能)派出者30天生存率10.8%(n=664),超过100秒(AHA可接受)派出者9.3%(n=2174),p=0.0013。
  • 一步法流程中应答延迟与30天生存无差异。
  • 二步法转接呼叫594,008次(6.1%),中位应答延迟39秒(IQR 30-53秒),但二步法流程的结局数据无法获取。

适用人群与场景

  • 瑞典紧急医疗调度中心10年间接听的医疗急救呼叫,其中一步法流程登记为院外心脏骤停的45,367例(0.5%)。
  • 二步法流程(呼叫转接至区域调度中心)的594,008次呼叫(6.1%),其结局数据无法获取。

诊断标准与关键阈值

  • AHA高性能目标:应答延迟10秒;救护车派出时间70秒。
  • AHA可接受标准:救护车派出时间100秒。

研究设计与关键结果

  • 观察性研究,数据来自瑞典心肺复苏登记处与紧急医疗调度中心,评估10年间一步法与二步法流程。
  • 共应答9,174,940次医疗呼叫(一步法),中位应答延迟7.3秒(IQR 3.6-14.5秒)。
  • 二步法转接594,008次呼叫(6.1%),中位应答延迟39秒(IQR 30-53秒)。
  • 一步法登记院外心脏骤停45,367例(0.5%),中位应答延迟7.2秒(IQR 3.6-14.1秒)(AHA高性能目标10秒)。
  • 一步法流程中,应答延迟与30天生存无差异。
  • 一步法院外心脏骤停救护车中位派出时间111.9秒(IQR 81.7-159.9秒)。
  • 救护车在70秒内(AHA高性能)派出者30天生存率10.8%(n=664),超过100秒(AHA可接受)派出者9.3%(n=2174),p=0.0013。
  • 二步法流程的结局数据无法获取。

证据类型、等级与局限

  • 证据类型:观察性研究。
  • 局限:二步法流程的结局数据无法获取。

对床旁实践的改变

  • 作者认为,当针对院外心脏骤停呼叫在AHA高性能标准内派出救护车时,生存率高于派出延迟的呼叫。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: To investigate the ability of Swedish Emergency Medical Dispatch Centres (EMDCs) to answer medical emergency calls and dispatch an ambulance for out-of-hospital cardiac arrest (OHCA) in accordance with the American Heart Association (AHA) performance goals in a 1-step (call connected directly to the EMDC) and a 2-step (call transferred to regional EMDC) procedure over 10 years, and to assess whether delays may be associated with 30-day survival.

METHOD: Observational data from the Swedish Registry for Cardiopulmonary Resuscitation and EMDC.

RESULTS: A total of 9,174,940 medical calls were answered (1-step). The median answer delay was 7.3 s (interquartile range [IQR], 3.6-14.5 s). Furthermore, 594,008 calls (6.1%) were transferred in a 2-step procedure, with a median answer delay of 39 s (IQR, 30-53 s). A total of 45,367 cases (0.5%, 1-step) were registered as OHCA, with a median answer delay of 7.2 s (IQR, 3.6-14.1 s) (AHA high-performance goal, 10 s). For 1-step procedure, no difference in 30-day survival was found regarding answer delay. For OHCA (1-step), an ambulance was dispatched after a median of 111.9 s (IQR, 81.7-159.9 s). Thirty-day survival was 10.8% (n = 664) when an ambulance was dispatched within 70 s (AHA high-performance) versus 9.3% (n = 2174) > 100 s (AHA acceptable) (p = 0.0013). Outcome data in the 2-step procedure was unobtainable.

CONCLUSION: The majority of calls were answered within the AHA performance goals. When an ambulance was dispatched within the AHA high-performance standard in response to OHCA calls, survival was higher compared with calls when dispatch was delayed.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Byrsell F, Jonsson M, Claesson A, et al. Swedish emergency medical dispatch centres' ability to answer emergency medical calls and dispatch an ambulance in response to out-of-hospital cardiac arrest calls in accordance with the American Heart Association performance goals: An observational study. Resuscitation. 2023. PMID: 37414242. doi:10.1016/j.resuscitation.2023.109896