环境空气污染物暴露与脓毒症患者急性呼吸窘迫综合征风险的关系
该前瞻性队列纳入1858例危重脓毒症患者,按居住地50 km内监测站日水平加权平均估算短期(3天)、中期(6周)、长期(5年)臭氧、NO2、SO2、CO、PM2.5、PM10暴露,用柏林标准随访6天评估ARDS。754例(41%)发生ARDS。短期和长期SO2、NO2、PM2.5暴露与ARDS风险相关(SO2长期暴露第75-25百分位比较OR 1.43,95%CI 1.16-1.77,p<0.01;NO2 OR 1.36,95%CI 1.06-1.74,p=0.04;PM2.5 OR 1.21,95%CI 1.04-1.41,p=0.03)。764例中这三种污染物长期暴露还与血浆IL-1受体拮抗剂和可溶性TNF受体-1浓度相关。
要点
- 危重脓毒症患者中41%(754/1858)在6天随访内按柏林标准发生ARDS。
- 长期SO2暴露第75-25百分位比较与ARDS风险升高相关:OR 1.43(95%CI 1.16-1.77),p<0.01。
- 长期NO2暴露与ARDS风险相关:OR 1.36(95%CI 1.06-1.74),p=0.04;PM2.5:OR 1.21(95%CI 1.04-1.41),p=0.03。
- 短期(3天)暴露于SO2、NO2、PM2.5同样与ARDS风险相关。
- 长期SO2、NO2、PM2.5暴露还与血浆IL-1受体拮抗剂和可溶性TNF受体-1浓度相关(764例)。
适用人群与场景
- 前瞻性队列中的1858例危重脓毒症患者。
- 764例患者检测了就诊时血浆炎症蛋白浓度。
诊断标准与关键阈值
- ARDS诊断采用柏林标准,随访6天。
- 污染物暴露按居住地50 km内监测站日水平加权平均估算:短期3天、中期6周、长期5年。
研究设计与关键结果
- 前瞻性队列研究,纳入1858例危重脓毒症患者,随访6天,754例(41%)发生ARDS。
- 短期和长期SO2、NO2、PM2.5暴露与ARDS风险相关:SO2长期暴露第75-25百分位比较OR 1.43(95%CI 1.16-1.77),p<0.01;NO2 OR 1.36(95%CI 1.06-1.74),p=0.04;PM2.5 OR 1.21(95%CI 1.04-1.41),p=0.03。
- 长期暴露于SO2、NO2、PM2.5还与血浆IL-1受体拮抗剂和可溶性TNF受体-1浓度相关(764例)。
证据类型、等级与局限
- 证据类型:前瞻性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为短期和长期暴露于环境SO2、PM2.5、NO2与脓毒症患者ARDS风险升高相关,代表脓毒症相关ARDS潜在可干预的环境危险因素。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
PURPOSE: Exposures to ambient air pollutants may prime the lung enhancing risk of acute respiratory distress syndrome (ARDS) in sepsis. Our objective was to determine the association of short-, medium-, and long-term pollutant exposures and ARDS risk in critically ill sepsis patients.
METHODS: We analyzed a prospective cohort of 1858 critically ill patients with sepsis, and estimated short- (3 days), medium- (6 weeks), and long- (5 years) term exposures to ozone, nitrogen dioxide (NO2), sulfur dioxide (SO2), carbon monoxide (CO), particulate matter < 2.5 μm (PM2.5), and PM < 10 μm (PM10) using weighted averages of daily levels from monitors within 50 km of subjects' residences. Subjects were followed for 6 days for ARDS by the Berlin Criteria. The association between each pollutant and ARDS was determined using multivariable logistic regression adjusting for preselected confounders. In 764 subjects, we measured plasma concentrations of inflammatory proteins at presentation and tested for an association between pollutant exposure and protein concentration via linear regression.
RESULTS: ARDS developed in 754 (41%) subjects. Short- and long-term exposures to SO2, NO2, and PM2.5 were associated with ARDS risk (SO2: odds ratio (OR) for the comparison of the 75-25th long-term exposure percentile 1.43 (95% confidence interval (CI) 1.16, 1.77); p < 0.01; NO2: 1.36 (1.06, 1.74); p = 0.04, PM2.5: 1.21 (1.04, 1.41); p = 0.03). Long-term exposures to these three pollutants were also associated with plasma interleukin-1 receptor antagonist and soluble tumor necrosis factor receptor-1 concentrations.
CONCLUSION: Short and long-term exposures to ambient SO2, PM2.5, and NO2 are associated with increased ARDS risk in sepsis, representing potentially modifiable environmental risk factors for sepsis-associated ARDS.
参考来源
- Reilly JP, Zhao Z, Shashaty MGS, et al. Exposure to ambient air pollutants and acute respiratory distress syndrome risk in sepsis. Intensive Care Med. 2023. PMID: 37470831. doi:10.1007/s00134-023-07148-y
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。