文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

潮式肺滞后量解读ARDS患者PEEP所致顺应性变化

Tidal lung hysteresis to interpret PEEP-induced changes in compliance in ARDS patients.
PubMed 文献 · Crit Care · 2023-06-13
一句话结论在COVID-19中重度ARDS的递减PEEP试验中,潮式滞后量≥100 mL高度预测下一步PEEP下调时的潮式复张(AUC 0.97)。

研究在38例COVID-19中重度ARDS患者中实施递减PEEP试验,每步在PEEP与恒定平台压之间行低流速充放气动作,测量潮式滞后量与顺应性。按潮式滞后量变化分为持续高复张10例(26%)、持续低复张12例(32%)和双相型16例(42%)。82%的PEEP下调后顺应性升高,其中44%伴潮式滞后量大幅升高;最佳顺应性与联合法一致性差(K=0.024)。联合法指导的PEEP较最佳顺应性法潮式滞后量更低(92.7±20.9 vs 204.7±110.0 mL,p<0.001)、每次呼吸耗散能更低(0.1±0.1 vs 0.4±0.2 J,p<0.001)。

要点

  • 潮式滞后量≥100 mL对下一步PEEP下调时潮式复张的预测AUC为0.97(p<0.001)。
  • 82%的PEEP下调步骤后顺应性升高,其中44%同时潮式滞后量大幅升高。
  • 38例中持续高复张10例(26%)、持续低复张12例(32%)、双相型16例(42%)。
  • 联合法较最佳顺应性法潮式滞后量更低(92.7±20.9 vs 204.7±110.0 mL,p<0.001)。
  • 联合法每次呼吸耗散能更低(0.1±0.1 vs 0.4±0.2 J,p<0.001)。

适用人群与场景

  • 38例COVID-19中重度ARDS患者,接受递减PEEP试验。

诊断标准与关键阈值

  • 潮式滞后量≥100 mL预测下一步PEEP下调时发生潮式复张(AUC 0.97;p<0.001)。

处置流程与药物剂量

  • 递减PEEP试验每一步在PEEP与恒定平台压之间行低流速充放气动作,测量潮式滞后量与顺应性。
  • 联合法建议:高潮式复张者增加PEEP,双相型者主要保持PEEP恒定,低潮式复张者降低PEEP。

研究设计与关键结果

  • 38例COVID-19中重度ARDS患者行递减PEEP试验,按潮式滞后量变化分为持续高复张10例(26%)、持续低复张12例(32%)、双相型16例(42%)。
  • 82%的PEEP下调步骤后顺应性升高,其中44%伴潮式滞后量大幅升高。
  • 最佳顺应性与联合法一致性差(K=0.024)。
  • 联合法指导的PEEP较最佳顺应性法潮式滞后量更低(92.7±20.9 vs 204.7±110.0 mL;p<0.001)、每次呼吸耗散能更低(0.1±0.1 vs 0.4±0.2 J;p<0.001)。
  • 潮式滞后量≥100 mL对下一步PEEP下调时潮式复张的预测AUC为0.97(p<0.001)。

证据类型、等级与局限

  • 研究论文,38例COVID-19中重度ARDS患者。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为潮式滞后量评估可改善递减PEEP试验的解读,可能有助于限制ARDS机械通气中的潮式复张和耗散能。
  • 高潮式复张者增加PEEP、双相型者主要保持PEEP恒定、低潮式复张者降低PEEP。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: In ARDS, the PEEP level associated with the best respiratory system compliance is often selected; however, intra-tidal recruitment can increase compliance, falsely suggesting improvement in baseline mechanics. Tidal lung hysteresis increases with intra-tidal recruitment and can help interpreting changes in compliance. This study aims to assess tidal recruitment in ARDS patients and to test a combined approach, based on tidal hysteresis and compliance, to interpret decremental PEEP trials.

METHODS: A decremental PEEP trial was performed in 38 COVID-19 moderate to severe ARDS patients. At each step, we performed a low-flow inflation-deflation manoeuvre between PEEP and a constant plateau pressure, to measure tidal hysteresis and compliance.

RESULTS: According to changes of tidal hysteresis, three typical patterns were observed: 10 (26%) patients showed consistently high tidal-recruitment, 12 (32%) consistently low tidal-recruitment and 16 (42%) displayed a biphasic pattern moving from low to high tidal-recruitment below a certain PEEP. Compliance increased after 82% of PEEP step decreases and this was associated to a large increase of tidal hysteresis in 44% of cases. Agreement between best compliance and combined approaches was accordingly poor (K = 0.024). The combined approach suggested to increase PEEP in high tidal-recruiters, mainly to keep PEEP constant in biphasic pattern and to decrease PEEP in low tidal-recruiters. PEEP based on the combined approach was associated with lower tidal hysteresis (92.7 ± 20.9 vs. 204.7 ± 110.0 mL; p < 0.001) and lower dissipated energy per breath (0.1 ± 0.1 vs. 0.4 ± 0.2 J; p < 0.001) compared to the best compliance approach. Tidal hysteresis ≥ 100 mL was highly predictive of tidal recruitment at next PEEP step reduction (AUC 0.97; p < 0.001).

CONCLUSIONS: Assessment of tidal hysteresis improves the interpretation of decremental PEEP trials and may help limiting tidal recruitment and energy dissipated into the respiratory system during mechanical ventilation of ARDS patients.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Mojoli F, Pozzi M, Arisi E, et al. Tidal lung hysteresis to interpret PEEP-induced changes in compliance in ARDS patients. Crit Care. 2023. PMID: 37312187. doi:10.1186/s13054-023-04506-6

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。