文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

辅助机械通气时呼吸系统顺应性计算的可靠性:一项回顾性研究

Reliability of Respiratory System Compliance Calculation During Assisted Mechanical Ventilation: A Retrospective Study.
PubMed 文献 · Crit Care Med · 2023-06-16
一句话结论在辅助机械通气中,吸气暂停时平台压视觉稳定至少2秒,可得到可靠的呼吸系统顺应性计算。

本研究为单中心回顾性观察研究,纳入101例在神经ICU中60分钟内先后接受控制与辅助机械通气并测量呼吸系统顺应性的成人患者。在两种通气模式下加入吸气暂停检测平台压(视觉稳定至少2秒视为可靠),计算呼吸系统顺应性和驱动压。Bland-Altman分析显示可接受的一致性(偏倚-3.9,一致性界限上限21.6、下限-29.6)。辅助通气时呼吸系统顺应性为64.1(52.6-79.3)mL/cm H2O,控制通气时为61.2(50-71.2)mL/cm H2O(P=0.006)。作者结论认为,平台压视觉稳定至少2秒可使辅助机械通气时的呼吸系统顺应性计算可靠。

要点

  • 在辅助机械通气中,将吸气暂停时视觉稳定至少2秒的平台压用于计算呼吸系统顺应性,Bland-Altman分析显示与控制通气测量可接受一致(偏倚-3.9,一致性界限上限21.6、下限-29.6)。
  • 101例神经ICU成人患者中,辅助通气时呼吸系统顺应性为64.1(52.6-79.3)mL/cm H2O,高于控制通气时的61.2(50-71.2)mL/cm H2O(P=0.006)。
  • 当峰压低于平台压或峰压高于平台压时,辅助通气与控制通气的呼吸系统顺应性均无统计学差异。
  • 平台压的可靠性以视觉稳定至少2秒为判断标准,据此计算的呼吸系统顺应性在辅助通气下可靠。

适用人群与场景

  • 年龄大于等于18岁、在神经ICU中60分钟内先后接受控制机械通气与辅助机械通气并测量呼吸系统顺应性的患者。

诊断标准与关键阈值

  • 平台压可靠性判断:平台压视觉稳定至少2秒视为可靠。

处置流程与药物剂量

  • 在控制机械通气和辅助机械通气中均加入吸气暂停以检测平台压,并计算呼吸系统顺应性和驱动压。

研究设计与关键结果

  • 单中心、回顾性、观察性研究,纳入101例神经ICU成人患者,比较控制机械通气与辅助机械通气时的呼吸系统顺应性计算。
  • Bland-Altman分析显示可接受一致性:偏倚-3.9,一致性界限上限21.6、下限-29.6。
  • 辅助机械通气时呼吸系统顺应性为64.1(52.6-79.3)mL/cm H2O,控制机械通气时为61.2(50-71.2)mL/cm H2O(P=0.006)。
  • 当峰压低于平台压时,以及当峰压高于平台压时,辅助通气与控制通气的呼吸系统顺应性均无统计学差异。

证据类型、等级与局限

  • 证据类型:单中心、回顾性、观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在辅助机械通气患者中,可通过吸气暂停获取视觉稳定至少2秒的平台压,用于计算呼吸系统顺应性;作者结论认为此举可使辅助机械通气时的呼吸系统顺应性计算可靠。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To compare respiratory system compliance (C rs ) calculation during controlled mechanical ventilation (MV) and, subsequently, during assisted MV.

DESIGN: This is a single-center, retrospective, observational study.

SETTING: This study was conducted on patients admitted to Neuro-ICU of Niguarda Hospital (tertiary referral hospital).

PATIENTS: We analyzed every patient greater than or equal to 18 years old having a C rs measurement in controlled and in assisted MV within 60 minutes. Plateau pressure (P plat ) was considered reliable if it was deemed visually stable for at least 2 seconds.

INTERVENTIONS: Inspiratory pause was incorporated to detect P plat in controlled and assisted MV. Calculation of C rs and driving pressure were achieved.

MEASUREMENTS AND MAIN RESULTS: A total of 101 patients were studied. An acceptable agreement was found (Bland-Altman plot bias -3.9, level of agreement upper 21.6, lower -29.6). C rs in assisted MV was 64.1 (52.6-79.3) and in controlled MV it was 61.2 (50-71.2) mL/cm H 2o ( p = 0.006). No statistical difference was found in C rs (assisted vs controlled MV) when peak pressure was lower than P plat nor when peak pressure was higher than P plat .

CONCLUSIONS: A P plat visually stable for at least 2 seconds leads to reliable C rs calculation during assisted MV.

来源:Crit Care Med,查看原文。版权归原作者所有。