文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

COVID-19 患者接受 vv-ECMO 期间呼吸系统顺应性变化轨迹对死亡率的预后价值

Prognostic value of respiratory compliance course on mortality in COVID-19 patients with vv-ECMO.
PubMed 文献 · Ann Intensive Care · 2023-06-21
一句话结论COVID-19 相关 ARDS 接受 vv-ECMO 者,植入后前 10 天静态呼吸系统顺应性变化轨迹与 180 天死亡率相关,可为重症医生提供预后信息。

这项在 3 个 ECMO 转诊中心开展的多中心回顾性研究纳入 2020 年 3 月 1 日至 2021 年 12 月 31 日接受 vv-ECMO 的 COVID-19 相关 ARDS 患者 122 例,均采用目标驱动压低于 15 cmH2O 的超保护性通气。中位年龄 59 岁(IQR 52-64),男性 83 例(68%),中位 BMI 33(28-37)kg/m2,首发症状至 vv-ECMO 植入间隔 16(10-21)天,6 个月死亡率为 48%。前 10 天内,180 天存活者顺应性从 18(12-25)升至 20(15-27)mL/cmH2O,非存活者从 12(9-20)降至 10(8-14)mL/cmH2O,交互作用 p<0.0001。时变多因素 Cox 模型显示年龄、慢性肺病史、第 1 至第 10 天顺应性及第 1 至第 10 天扫气流量为 180 天死亡率的独立相关因素。作者认为,该信息可为重症医生判断患者预后提供关键参考。

要点

  • vv-ECMO 植入后前 10 天静态呼吸系统顺应性上升者 180 天存活率更高:存活者从 18(12-25)升至 20(15-27)mL/cmH2O,非存活者从 12(9-20)降至 10(8-14)mL/cmH2O,交互作用 p<0.0001。
  • 时变多因素 Cox 模型显示,年龄、慢性肺病史、第 1 至第 10 天顺应性、第 1 至第 10 天扫气流量为 180 天死亡率独立相关因素。
  • 本队列 6 个月死亡率为 48%,中位年龄 59 岁(IQR 52-64),男性 83 例(68%),中位 BMI 33(28-37)kg/m2。
  • 所有患者均采用目标驱动压低于 15 cmH2O 的超保护性通气设置。
  • 首发症状至 vv-ECMO 植入中位间隔 16(10-21)天。

适用人群与场景

  • 2020 年 3 月 1 日至 2021 年 12 月 31 日在 3 个 ECMO 转诊中心接受 vv-ECMO 支持的 COVID-19 相关 ARDS 患者。

处置流程与药物剂量

  • 所有患者均采用超保护性通气设置,目标驱动压低于 15 cmH2O。

研究设计与关键结果

  • 多中心回顾性研究,纳入 3 个 ECMO 转诊中心的 122 例 COVID-19 相关 ARDS 接受 vv-ECMO 患者;中位年龄 59 岁(IQR 52-64),男性 83 例(68%),中位 BMI 33(28-37)kg/m2,首发症状至 vv-ECMO 植入间隔 16(10-21)天。
  • 6 个月死亡率为 48%。
  • 前 10 天内,180 天存活者静态呼吸系统顺应性从 18(12-25)升至 20(15-27)mL/cmH2O,非存活者从 12(9-20)降至 10(8-14)mL/cmH2O,交互作用 p<0.0001。
  • 时变多因素 Cox 模型显示,年龄、慢性肺病史、第 1 至第 10 天顺应性、第 1 至第 10 天扫气流量为 180 天死亡率的独立相关因素。

证据类型、等级与局限

  • 证据类型:多中心回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,vv-ECMO 植入后前 10 天静态呼吸系统顺应性变化轨迹与 180 天死亡率相关,可为重症医生判断患者预后提供关键信息。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: COVID-19-associated acute respiratory distress syndrome (ARDS) supported by veno-venous extra-corporal membrane oxygenation (vv-ECMO) results in a high in-hospital mortality rate of more than 35%. However, after cannulation, no prognostic factor has been described to guide the management of these patients. The objective was to assess the association between static respiratory compliance over the first 10 days post-vv-ECMO implantation on 180-day mortality.

RESULTS: In this multicentric retrospective study in three ECMO referral centers, all patients with COVID-19-associated ARDS supported by vv-ECMO were included from 03/01/2020 to 12/31/2021. Patients were ventilated with ultra-protective settings targeting a driving pressure lower than 15 cmH2O. 122 patients were included. Median age was 59 IQR (52-64), 83 (68%) were male, with a median body mass index of 33 (28-37) kg/m2. Delay between first symptoms to vv-ECMO implantation was 16 (10-21) days. Six-month death was 48%. Over the first ten days, compliance increased in 180 day survivors [from 18 (12-25) to 20 (15-27) mL/cmH2O] compared to non-survivors [from 12 (9-20) to 10 (8-14) mL/cmH2O, p interaction < 0.0001]. A time varying multivariable Cox model found age, history of chronic lung disease, compliance from day one to day ten and sweep gas flow from day one to day ten as independent factors associated with 180-day mortality.

CONCLUSIONS: In COVID-19-associated ARDS, static respiratory compliance course over the first ten days post-vv-ECMO implantation is associated with 180-day mortality. This new information may provide crucial information on the patient's prognosis for intensivists.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Valentin S, Amalric M, Granier G, et al. Prognostic value of respiratory compliance course on mortality in COVID-19 patients with vv-ECMO. Ann Intensive Care. 2023. PMID: 37341800. doi:10.1186/s13613-023-01152-7

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。